scispace - formally typeset
Proceedings ArticleDOI

A New Single-Phase PLL Structure Based on Second Order Generalized Integrator

Reads0
Chats0
TLDR
In this article, a phase-locked-loop (PLL) method for single-phase systems was proposed to detect the phase angle, amplitude and frequency of the utility voltage.
Abstract
Phase, amplitude and frequency of the utility voltage are critical information for the operation of the grid-connected inverter systems. In such applications, an accurate and fast detection of the phase angle, amplotude and frequency of the utility voltage is essential to assure the correct generation of the reference signals and to cope with the new upcoming standards. This paper presents a new phase-locked-loop (PLL) method for single-phase systems. The novelty consists in generating the orthogonal voltage system using a structure based on second order generalized integrator (SOGI). The proposed structure has the following advantages: — it has a simple implementation; — the generated orthogonal system is filtered without delay by the same structure due to its resonance at the fundamental frequency, — the proposed structure is not affected by the frequency changes. The solutions for the discrete implementation of the new proposed structure are also presented. Experimental results validate the effectiveness of the proposed method.

read more

Citations
More filters
Journal ArticleDOI

Multiresonant Frequency-Locked Loop for Grid Synchronization of Power Converters Under Distorted Grid Conditions

TL;DR: A new multiresonant frequency-adaptive synchronization method for grid-connected power converters that allows estimating not only the positive- and negative-sequence components of the power signal at the fundamental frequency but also other sequence components at other harmonic frequencies is presented.
Journal ArticleDOI

Self-Synchronized Synchronverters: Inverters Without a Dedicated Synchronization Unit

TL;DR: In this paper, a self-synchronized synchronverter is proposed to improve the performance of grid-connected inverters by removing the dedicated synchronization unit, which can automatically synchronize itself with the grid before connection and track the grid frequency after connection.
Journal ArticleDOI

A Stationary Reference Frame Grid Synchronization System for Three-Phase Grid-Connected Power Converters Under Adverse Grid Conditions

TL;DR: A new grid synchronization method for three-phase three-wire networks, namely dual second-order generalized integrator (SOGI) frequency-locked loop, based on two adaptive filters, is presented, able to perform an excellent estimation of the instantaneous symmetrical components of the grid voltage under unbalanced and distorted grid conditions.
Journal ArticleDOI

Three-Phase PLLs: A Review of Recent Advances

TL;DR: A phase-locked loop (PLL) is a nonlinear negative feedback control system that synchronizes its output in frequency as well as in phase with its input PLLs are now widely used for the synchronization of power-electronics-based converters and also for monitoring and control purposes in different engineering fields as mentioned in this paper.
Journal ArticleDOI

Secondary Control Scheme for Voltage Unbalance Compensation in an Islanded Droop-Controlled Microgrid

TL;DR: The results show the effectiveness of the proposed control structure in compensating the voltage unbalance in an islanded microgrid.
References
More filters
Journal ArticleDOI

Stationary frame current regulation of PWM inverters with zero steady-state error

TL;DR: In this article, the P+Resonant regulator is proposed, which achieves the same transient and steady-state performance as a synchronous frame PI regulator and is applicable to both single-phase and three-phase inverters.
Proceedings ArticleDOI

Stationary-frame generalized integrators for current control of active power filters with zero steady-state error for current harmonics of concern under unbalanced and distorted operating conditions

TL;DR: In this paper, the authors proposed several concepts of integrators for sinusoidal signals, including parallel and series associations of the basic PI units using the stationary frame generalized integrators, for current control of active power filters.
Proceedings ArticleDOI

A new control structure for grid-connected LCL PV inverters with zero steady-state error and selective harmonic compensation

TL;DR: In this article, a new control strategy aimed to mitigate the PI current control of a single-phase inverter has been proposed, where Stationary-frame generalized integrators are used to control the fundamental current and to compensate the grid harmonics providing disturbance rejection capability without the need of feed-forward grid compensation.
Proceedings ArticleDOI

PLL structures for utility connected systems

TL;DR: In this paper, a detailed analysis of phase-locked loop structures for utility connected systems is presented, and a single-phase PLL structure derived from the three-phase topology is discussed and its behavior under distorted utility conditions is analyzed.
Journal ArticleDOI

Control of single-stage single-phase PV inverter

TL;DR: In this article, a complete control structure for the single-phase photovoltaic (PV) system is presented, where the main elements of the PV control structure are: - a maximum power point tracker (MPPT) algorithm using the incremental conductance method; - a synchronization method using the phase-locked-loop (PLL), based on delay; the input power control using the dc voltage controller and power feed-forward; - and the grid current controller implemented in two different ways, using the classical proportional integral (PI) and the novel proportional resonant (