Adaptive hydrostatic blood pressure calibration: Development of a wearable, autonomous pulse wave velocity blood pressure monitor

Reads0
Chats0
TLDR
The adaptive system identification method utilizes a measurable intra-arterial hydrostatic pressure change in the sensor outfitted appendage to identify the transduction dynamics relating the peripheral arterial blood pressure and the measured arterial sensor signal.
Abstract
A technique for calibrating non-invasive peripheral arterial sensor signals to peripheral arterial blood pressure (BP) is proposed. The adaptive system identification method utilizes a measurable intra-arterial hydrostatic pressure change in the sensor outfitted appendage to identify the transduction dynamics relating the peripheral arterial blood pressure and the measured arterial sensor signal. The proposed algorithm allows identification of the calibration dynamics despite unknown physiologic fluctuations in arterial pressure during the calibration period under certain prescribed conditions. By employing unique wearable sensor architecture to estimate pulse wave velocity (PWV), this technique is used to calibrate peripheral pulse transit time measurements to arterial blood pressure. This sensor architecture is comprised of two inline photoplethysmograph sensors one in the form of a wristwatch measuring the pulse waveform in the ulnar artery and one in the form of a ring measuring the pulse waveform from the digital artery along the base of the little finger. Experimental results using the proposed algorithm to calibrate PTT to BP on human subjects will be presented.

read more

Citations
More filters
Journal ArticleDOI

The use of photoplethysmography for assessing hypertension

TL;DR: Although the technology is not yet mature, it is anticipated that in the near future, accurate, continuous BP measurements may be available from mobile and wearable devices given their vast potential.
Journal ArticleDOI

A survey on signals and systems in ambulatory blood pressure monitoring using pulse transit time

TL;DR: A literature survey covering recent developments is presented in order to identify gaps in the literature regarding the calibration of pulse transit/arrival times to blood pressure, acquisition and processing of physiological signals and the design of fully integrated blood pressure measurement systems.
Journal ArticleDOI

Noninvasive and Nonocclusive Blood Pressure Estimation Via a Chest Sensor

TL;DR: A sensor and a calibration strategy to perform MAP measurements at the chest and the encouraging performance of the presented technique paves the way toward an ambulatory compliant, continuous, and nonocclusive BP monitoring system.
Journal ArticleDOI

Feasibility study for the non-invasive blood pressure estimation based on ppg morphology: normotensive subject study.

TL;DR: Pressure index (PI) is suggested as a promising additional parameter for the cuff less blood pressure monitoring by combining of statistically significant segments of photoplethysmographic waveform.
Patent

Calibration of Pulse Transit Time Measurements to Arterial Blood Pressure using External Arterial Pressure Applied along the Pulse Transit Path

TL;DR: In this paper, an adaptive and autonomous calibration of pulse transit time measurements to obtain arterial blood pressure using arterial pressure variation is presented, using a distributed model with lumped parameters.
References
More filters
Journal ArticleDOI

Adaptive noise cancelling: Principles and applications

TL;DR: It is shown that in treating periodic interference the adaptive noise canceller acts as a notch filter with narrow bandwidth, infinite null, and the capability of tracking the exact frequency of the interference; in this case the canceller behaves as a linear, time-invariant system, with the adaptive filter converging on a dynamic rather than a static solution.
Journal ArticleDOI

Hypertension in adults across the age spectrum: current outcomes and control in the community.

TL;DR: In this article, the prevalence of hypertension and drug treatment increased with advancing age, whereas control rates were markedly lower in older women (systolic <140 and diastolic <90 mm Hg).
Journal ArticleDOI

Continuous estimation of systolic blood pressure using the pulse arrival time and intermittent calibration

TL;DR: The results showed that the correlation coefficients between estimated values and invasively obtained systolic blood pressure reached 0.97±0.02, and the error remained within ±10% in 97.8% of the monitoring period.
Journal ArticleDOI

Hypertension: trends in prevalence, incidence, and control.

TL;DR: Hypertension is the leading cause of cardiovascular disease worldwide, and an estimated 972 million people in the world are suffering from this problem; however, recent data suggest that it is again on the rise.
Proceedings ArticleDOI

Hint for squint: a computer reliant diagnostic aid for strabismus

TL;DR: This paper provides an outline of methods used for the implementation of a computer reliant diagnostic aid in the medical specialty of Ophthalmology and indicates that the most serious problems were inability to handle and lack of inclusive physician-approved data banks.
Related Papers (5)