scispace - formally typeset
Search or ask a question
Journal ArticleDOI

Automatic Identification and Removal of Ocular Artifacts in EEG—Improved Adaptive Predictor Filtering for Portable Applications

29 Apr 2014-IEEE Transactions on Nanobioscience (IEEE Trans Nanobioscience)-Vol. 13, Iss: 2, pp 109-117
TL;DR: A hybrid de-noising method combining Discrete Wavelet Transformation (DWT) and an Adaptive Predictor Filter (APF) based on an adaptive autoregressive model for prediction of the waveform of signals in the ocular artifact zones that is well suited to applications in portable environments.
Abstract: Electroencephalogram (EEG) signals have a long history of use as a noninvasive approach to measure brain function. An essential component in EEG-based applications is the removal of Ocular Artifacts (OA) from the EEG signals. In this paper we propose a hybrid de-noising method combining Discrete Wavelet Transformation (DWT) and an Adaptive Predictor Filter (APF). A particularly novel feature of the proposed method is the use of the APF based on an adaptive autoregressive model for prediction of the waveform of signals in the ocular artifact zones. In our test, based on simulated data, the accuracy of noise removal in the proposed model was significantly increased when compared to existing methods including: Wavelet Packet Transform (WPT) and Independent Component Analysis (ICA), Discrete Wavelet Transform (DWT) and Adaptive Noise Cancellation (ANC). The results demonstrate that the proposed method achieved a lower mean square error and higher correlation between the original and corrected EEG. The proposed method has also been evaluated using data from calibration trials for the Online Predictive Tools for Intervention in Mental Illness (OPTIMI) project. The results of this evaluation indicate an improvement in performance in terms of the recovery of true EEG signals with EEG tracking and computational speed in the analysis. The proposed method is well suited to applications in portable environments where the constraints with respect to acceptable wearable sensor attachments usually dictate single channel devices.
Citations
More filters
Journal ArticleDOI
TL;DR: A review of the existing state-of-the-art artifact detection and removal methods from scalp EEG for all potential EEG-based applications and analyses the pros and cons of each method is presented in this paper.
Abstract: Electroencephalography (EEG) is the most popular brain activity recording technique used in wide range of applications. One of the commonly faced problems in EEG recordings is the presence of artifacts that come from sources other than brain and contaminate the acquired signals significantly. Therefore, much research over the past 15 years has focused on identifying ways for handling such artifacts in the preprocessing stage. However, this is still an active area of research as no single existing artifact detection/removal method is complete or universal. This article presents an extensive review of the existing state-of-the-art artifact detection and removal methods from scalp EEG for all potential EEG-based applications and analyses the pros and cons of each method. First, a general overview of the different artifact types that are found in scalp EEG and their effect on particular applications are presented. In addition, the methods are compared based on their ability to remove certain types of artifacts and their suitability in relevant applications (only functional comparison is provided not performance evaluation of methods). Finally, the future direction and expected challenges of current research is discussed. Therefore, this review is expected to be helpful for interested researchers who will develop and/or apply artifact handling algorithm/technique in future for their applications as well as for those willing to improve the existing algorithms or propose a new solution in this particular area of research.

262 citations

Journal ArticleDOI
TL;DR: A critical review of EEG artifact removal approaches is presented, their applicability to daily-life EEG-BCI applications is discussed, and some directions and guidelines for upcoming research in this topic are given.

217 citations


Cites background or methods from "Automatic Identification and Remova..."

  • ...They are based on single-channel ICA [148], EMD [123,125] or wavelet decomposition [121,129,136]....

    [...]

  • ...The requirement of simple electrical montage (used in [121,126,136]) limits the use of procedures that require information from multiple channels....

    [...]

  • ...The latter has low computing cost and takes advantage of the fact that ocular artifacts are localized at low frequency bands [136]....

    [...]

  • ...Regarding the low quantity of studies that used portablewearable-wireless devices [121,136], it might be caused by the recent commercialization of these systems....

    [...]

Journal ArticleDOI
TL;DR: This paper presents an extensive overview of the existing methods for ocular, muscle, and cardiac artifact identification and removal with their comparative advantages and limitations and reviewed the schemes developed for validating the performances of algorithms with simulated and real EEG data.
Abstract: Electroencephalogram (EEG), boasting the advantages of portability, low cost, and high-temporal resolution, is a non-invasive brain-imaging modality that can be used to measure different brain states. However, EEG recordings are always contaminated with artifacts from different sources other than neurons, which renders EEG data analysis more difficult, and which potentially results in misleading findings. Therefore, it is essential for many medical and practical applications to remove these artifacts in the preprocessing stage before analyzing EEG data. In the last thirty years, various methods have been developed to remove different types of artifacts from contaminated EEG data; still though, there is no standard method that can be used optimally, and therefore, the research remains attractive as well as challenging. This paper presents an extensive overview of the existing methods for ocular, muscle, and cardiac artifact identification and removal with their comparative advantages and limitations. We also reviewed the schemes developed for validating the performances of algorithms with simulated and real EEG data. In future studies, researchers should focus not only on the combining of different methods with multiple processing stages for efficient removal of artifactual interferences but also on the development of standard criteria for validation of recorded EEG signals.

119 citations

Journal ArticleDOI
Gang Wang1, Chaolin Teng1, Kuo Li1, Zhonglin Zhang1, Xiangguo Yan1 
TL;DR: By using independent component analysis (ICA) and multivariate empirical mode decomposition (MEMD), the ICA-based MEMD method was proposed to remove EOG artifacts (EOAs) from multichannel EEG signals and preserve useful EEG information with little loss.
Abstract: The recorded electroencephalography (EEG) signals are usually contaminated by electrooculography (EOG) artifacts. In this paper, by using independent component analysis (ICA) and multivariate empirical mode decomposition (MEMD), the ICA-based MEMD method was proposed to remove EOG artifacts (EOAs) from multichannel EEG signals. First, the EEG signals were decomposed by the MEMD into multiple multivariate intrinsic mode functions (MIMFs). The EOG-related components were then extracted by reconstructing the MIMFs corresponding to EOAs. After performing the ICA of EOG-related signals, the EOG-linked independent components were distinguished and rejected. Finally, the clean EEG signals were reconstructed by implementing the inverse transform of ICA and MEMD. The results of simulated and real data suggested that the proposed method could successfully eliminate EOAs from EEG signals and preserve useful EEG information with little loss. By comparing with other existing techniques, the proposed method achieved much improvement in terms of the increase of signal-to-noise and the decrease of mean square error after removing EOAs.

110 citations


Cites background from "Automatic Identification and Remova..."

  • ...Digital Object Identifier 10.1109/JBHI.2015.2450196 electrooculography (EOG) activities whose magnitude is usually much higher than that of EEG signals....

    [...]

Journal ArticleDOI
TL;DR: The paper is a review vision about the works in the area of EEG applied to healthcare and summarizes the challenges, research gaps, and opportunities to improve the EEG big data artifacts removal more precisely.
Abstract: Electroencephalogram (EEG) signals are progressively growing data widely known as biomedical big data, which is applied in biomedical and healthcare research. The measurement and processing of EEG ...

55 citations

References
More filters
Book ChapterDOI
01 Jan 1995
TL;DR: A reconstruction subject to far weaker Gibbs phenomena than thresholding based De-Noising using the traditional orthogonal wavelet transform is produced.
Abstract: De-Noising with the traditional (orthogonal, maximally-decimated) wavelet transform sometimes exhibits visual artifacts; we attribute some of these—for example, Gibbs phenomena in the neighborhood of discontinuities—to the lack of translation invariance of the wavelet basis. One method to suppress such artifacts, termed “cycle spinning” by Coifman, is to “average out” the translation dependence. For a range of shifts, one shifts the data (right or left as the case may be), De-Noises the shifted data, and then unshifts the de-noised data. Doing this for each of a range of shifts, and averaging the several results so obtained, produces a reconstruction subject to far weaker Gibbs phenomena than thresholding based De-Noising using the traditional orthogonal wavelet transform.

1,888 citations


"Automatic Identification and Remova..." refers background or methods in this paper

  • ...a soft threshold [13] to the three lowest level coefficients to...

    [...]

  • ...Based on the minimum risk value, we select the soft threshold as discussed in [13] and apply them to the node coef-...

    [...]

Journal ArticleDOI
TL;DR: A completely automatic algorithm (ADJUST) that identifies artifacted independent components by combining stereotyped artifact-specific spatial and temporal features is proposed that provides a fast, efficient, and automatic way to use ICA for artifact removal.
Abstract: A successful method for removing artifacts from electroencephalogram (EEG) recordings is Independent Component Analysis (ICA), but its implementation remains largely user-dependent. Here, we propose a completely automatic algorithm (ADJUST) that identifies artifacted independent components by combining stereotyped artifact-specific spatial and temporal features. Features were optimized to capture blinks, eye movements, and generic discontinuities on a feature selection dataset. Validation on a totally different EEG dataset shows that (1) ADJUST’s classification of independent components largely matches a manual one by experts (agreement on 95.2% of the data variance), and (2) Removal of the artifacted components detected by ADJUST leads to neat reconstruction of visual and auditory eventrelated potentials from heavily artifacted data. These results demonstrate that ADJUST provides a fast, efficient, and automatic way to use ICA for artifact removal. Descriptors: Electroencephalography, Independent component analysis, EEG artifacts, EEG artefacts, Event-related potentials, Ongoing brain activity, Automatic classification, Thresholding

1,060 citations

Journal ArticleDOI
Hasan Ocak1
TL;DR: It was shown that epileptic EEG had significant nonlinearity whereas normal EEG behaved similar to Gaussian linear stochastic process.
Abstract: In this study, a new scheme was presented for detecting epileptic seizures from electro-encephalo-gram (EEG) data recorded from normal subjects and epileptic patients. The new scheme was based on approximate entropy (ApEn) and discrete wavelet transform (DWT) analysis of EEG signals. Seizure detection was accomplished in two stages. In the first stage, EEG signals were decomposed into approximation and detail coefficients using DWT. In the second stage, ApEn values of the approximation and detail coefficients were computed. Significant differences were found between the ApEn values of the epileptic and the normal EEG allowing us to detect seizures with over 96% accuracy. Without DWT as preprocessing step, it was shown that the detection rate was reduced to 73%. The analysis results depicted that during seizure activity EEG had lower ApEn values compared to normal EEG. This suggested that epileptic EEG was more predictable or less complex than the normal EEG. The data was further analyzed with surrogate data analysis methods to test for evidence of nonlinearities. It was shown that epileptic EEG had significant nonlinearity whereas normal EEG behaved similar to Gaussian linear stochastic process.

687 citations


Additional excerpts

  • ...of non-stationary signals such as EEG [14]–[16]....

    [...]

Journal ArticleDOI
TL;DR: Although the focus is on eliminating ocular artifacts in EEG data, the approach can be extended to other sources of EEG contamination such as cardiac signals, environmental noise, and electrode drift, and adapted for use with magnetoencephalographic (MEG) data, a magnetic correlate of EEG.
Abstract: Signals from eye movements and blinks can be orders of magnitude larger than brain-generated electrical potentials and are one of the main sources of artifacts in electroencephalographic (EEG) data. Rejecting contaminated trials causes substantial data loss, and restricting eye movements/blinks limits the experimental designs possible and may impact the cognitive processes under investigation. This article presents a method based on blind source separation (BSS) for automatic removal of electroocular artifacts from EEG data. BBS is a signal-processing methodology that includes independent component analysis (ICA). In contrast to previously explored ICA-based methods for artifact removal, this method is automated. Moreover, the BSS algorithm described herein can isolate correlated electroocular components with a high degree of accuracy. Although the focus is on eliminating ocular artifacts in EEG data, the approach can be extended to other sources of EEG contamination such as cardiac signals, environmental noise, and electrode drift, and adapted for use with magnetoencephalographic (MEG) data, a magnetic correlate of EEG.

608 citations


"Automatic Identification and Remova..." refers methods in this paper

  • ...Several methods have been tried to automatically identify the artifact zones, see [17]–[19]....

    [...]

Journal ArticleDOI
TL;DR: A method for removing ocular artifacts based on adaptive filtering that is easy to implement and stable, converges fast and is suitable for on-line removal of EOG artifacts.
Abstract: The electro-encephalogram (EEG) is useful for clinical diagnosts and in biomedical research. EEG signals, however, especially those recorded from frontal channels, often contain strong electro-oculogram (EOG) artifacts produced by eye movements. Existing regression-based methods for removing EOG artifacts require various procedures for preprocessing and calibration that are inconvenient and timeconsuming. The paper describes a method for removing ocular artifacts based on adaptive filtering. The method uses separately recorded vertical EOG and horizontal EOG signals as two reference inputs. Each reference input is first processed by a finite impulse response filter of length M (M=3 in this application) and then subtracted from the original EEG. The method is implemented by a recursive leastsquares algorithm that includes a forgetting factor (λ=0.9999 in this application) to track the non-stationary portion of the EOG signals. Results from experimental data demonstrate that the method is easy to implement and stable, converges fast and is suitable for on-line removal of EOG artifacts. The first three coefficients (up to M=3) were significantly larger than any remaining coefficients.

334 citations