Bioelectrical Impedance Methods for Noninvasive Health Monitoring: A Review.

17 Jun 2014-Vol. 2014, pp 381251-381251
TL;DR: The working principles, applications, merits, and demerits of these methods has been discussed in detail along with their other technical issues followed by present status and future trends.
Abstract: Under the alternating electrical excitation, biological tissues produce a complex electrical impedance which depends on tissue composition, structures, health status, and applied signal frequency, and hence the bioelectrical impedance methods can be utilized for noninvasive tissue characterization. As the impedance responses of these tissue parameters vary with frequencies of the applied signal, the impedance analysis conducted over a wide frequency band provides more information about the tissue interiors which help us to better understand the biological tissues anatomy, physiology, and pathology. Over past few decades, a number of impedance based noninvasive tissue characterization techniques such as bioelectrical impedance analysis (BIA), electrical impedance spectroscopy (EIS), electrical impedance plethysmography (IPG), impedance cardiography (ICG), and electrical impedance tomography (EIT) have been proposed and a lot of research works have been conducted on these methods for noninvasive tissue characterization and disease diagnosis. In this paper BIA, EIS, IPG, ICG, and EIT techniques and their applications in different fields have been reviewed and technical perspective of these impedance methods has been presented. The working principles, applications, merits, and demerits of these methods has been discussed in detail along with their other technical issues followed by present status and future trends.

Content maybe subject to copyright    Report

Citations
More filters
Book ChapterDOI
01 Jan 2021
TL;DR: In this paper, the authors describe methods for the assessment of fluid volume status, compare their relative advantages and limitations and propose research priorities in this area, including extracellular and intracellular fluid status.
Abstract: Increased body fluid volume portends poorer outcomes in both acute and chronic heart failure. Inadequate decongestion, defined as absence of hemoconcentration or increases in serum creatinine, is consistently associated with higher rates of heart failure hospitalizations and cardiovascular mortality. However, available means to identify and quantify abnormal fluid volume, monitor changes during decongestive therapies and determine when an optimal fluid volume has been achieved are poorly understood. In addition, ideal methods to assess extracellular and intracellular fluid status remain elusive. These knowledge gaps lead to unacceptably poor heart failure outcomes, as underscored by the results of many acute heart failure trials in which, regardless of decongestive therapy, only a small minority of patients achieve optimal volume status. The intent of this discussion is to describe methods for the assessment of fluid volume status, compare their relative advantages and limitations and propose research priorities in this area.

2 citations

Journal ArticleDOI
TL;DR: In this article, the freezing resistance of floribunda roses (Rosa Floribunda) during frost dehardening using the EIT technique to identify a new method for rapid and non-destructive measurement of plant freezing resistance.
Abstract: Electrical impedance tomography (EIT) has rarely been applied in plant science, particularly to study plant resistance to abiotic and biotic stresses. In this study, we evaluated the freezing resistance of floribunda roses (Rosa Floribunda) during frost dehardening using the EIT technique to identify a new method for rapid and non-destructive measurement of plant freezing resistance. The current was the excitation source, the boundary voltage value was measured, and then the boundary voltage reconstructed value was formed. Using an imaging algorithm, the two-dimensional (2D) distribution of impedance or impedance variation was reconstructed. The EIT reconstructed values decreased obviously with the decline in freezing temperatures. The EIT reconstructed values of stems had the best fit to the logistic equation, and subsequently, the semi-lethal temperatures were calculated. The freezing resistance results evaluated using EIT reconstructed values were linearly correlated with the results of the traditional electrolyte leakage (EL) method (r = 0.93, P < 0.01). In conclusion, after freezing tests, the reconstructed values of EIT images could be used to quantitatively evaluate the freezing resistance of floribunda rose stems. The present study provides a reference for the further application of the EIT technique for non-destructive and rapid detection of plant freezing resistance.

2 citations

Journal ArticleDOI
TL;DR: A etiologia mais comum foi o virus da hepatite C. C. e modelo para doenca hepatica final de 12 pontos; houve predominância de homens.
Abstract: 58 anos) e modelo para doenca hepatica final de 12 pontos; houve predominância de homens. A etiologia mais comum (60,4%) foi o virus da hepatite C. Os valores de corte foram MAMC ≤ 25,09 cm para a massa muscular, PT ≤ 93,4 Nm para a forca muscular e 6MWT ≤ 459 m para a funcao muscular. e as precisoes usadas para determinar a massa muscular, forca e funcao pelo MAMC, PT e 6MWT foram ≤ 25,09 cm e 77,9%, ≤ 93,4Nm e 72,72% e ≤ 459 me 75%, respectivamente.

2 citations


Cites background from "Bioelectrical Impedance Methods for..."

  • ...Patients with cirrhosis present changes in body composition due to ascites and edema, which overestimate lean body mass assessed by dual-energy X-ray absorptiometry[13] and bioimpedance analysis[16]....

    [...]

  • ...However, these diagnostic methods are expensive, involve significant radiation exposure[16,17], and require special software for calculating muscle surface area[17]....

    [...]

Journal ArticleDOI
TL;DR: In this article, a simple, passive, single-element ultrasonic transducer is proposed for non-invasive measurements, operating at different resonant modes allows the adaptation of the emitted sound pattern to various requirements.
Abstract: A simple, passive, single-element ultrasonic transducer is proposed for non-invasive measurements. Operating the transducer at different resonant modes allows the adaptation of the emitted sound pattern to various requirements. The emitted sound field is simulated and experimentally characterized. We demonstrate the suitability of the transducer prototype for non-invasive continuous level measurement in laboratory as well as field environment over an extended level- and temperature range. The measured performance fulfils typical requirements for invasive level sensors. The versatility of the transducer enables its application in a wide range of non-invasive measurements.

2 citations


Cites background from "Bioelectrical Impedance Methods for..."

  • ...Especially in some industrial measurements [1]–[5] and medical applications [6], [7] it is an asset if the sensor does not penetrate some boundaries....

    [...]

Journal ArticleDOI
TL;DR: In this article, the authors analyzed changes in impedance parameters, and tissue and molecular alterations that allow us to identify the time of ischemia in which the gastric mucosa still maintains its barrier function.
Abstract: Gastrointestinal ischemia may be presented as a complication associated with late shock detection in patients in critical condition. Prolonged ischemia can cause mucosal integrity to lose its barrier function, triggering alterations that can induce organ dysfunction and lead to death. Electrical impedance spectroscopy has been proposed to identify early alteration in ischemia-induced gastric mucosa in this type of patients. This work analyzed changes in impedance parameters, and tissue and molecular alterations that allow us to identify the time of ischemia in which the gastric mucosa still maintains its barrier function. The animals were randomly distributed in four groups: Control, Ischemia 60, 90, and 120 min. Impedance parameters were measured and predictive values were determined to categorize the degree of injury using a receiver operating characteristic curve. Markers of inflammatory process and apoptosis (iNOS, TNFα, COX-2, and Caspase-3) were analyzed. The largest increase in impedance parameters occurred in the ischemia 90 and 120 min groups, with resistance at low frequencies (RL) and reactance at high frequencies (XH) being the most related to damage, allowing prediction of the occurrence of reversible and irreversible tissue damage. Histological analysis and apoptosis assay showed progressive mucosal deterioration with irreversible damage (p < 0.001) starting from 90 min of ischemia. Furthermore, a significant increase in the expression of iNOS, TNFα, and COX-2 was identified in addition to apoptosis in the gastric mucosa starting from 90 min of ischemia. Tissue damage generated by an ischemia time greater than 60 min induces loss of barrier function in the gastric mucosa.

2 citations

References
More filters
Book
01 Nov 2011
TL;DR: In this paper, the authors focus on topics at the forefront of electrochemical research, such as splitting water by electrolysis, splitting water with visible light, and the recent development of lithium batteries.
Abstract: This book focuses on topics at the forefront of electrochemical research. Splitting water by electrolysis; splitting water by visible light; the recent development of lithium batteries; theoretical approaches to intercalation; and fundamental concepts of electrode kinetics, particularly as applied to semiconductors are discussed. It is recommended for electrochemists, physical chemists, corrosion scientists, and those working in the fields of analytical chemistry, surface and colloid science, materials science, electrical engineering, and chemical engineering.

5,927 citations

Book
01 Jan 1971

5,389 citations

BookDOI
04 Apr 2005
Abstract: Preface. Preface to the First Edition. Contributors. Contributors to the First Edition. Chapter 1. Fundamentals of Impedance Spectroscopy (J.Ross Macdonald and William B. Johnson). 1.1. Background, Basic Definitions, and History. 1.1.1 The Importance of Interfaces. 1.1.2 The Basic Impedance Spectroscopy Experiment. 1.1.3 Response to a Small-Signal Stimulus in the Frequency Domain. 1.1.4 Impedance-Related Functions. 1.1.5 Early History. 1.2. Advantages and Limitations. 1.2.1 Differences Between Solid State and Aqueous Electrochemistry. 1.3. Elementary Analysis of Impedance Spectra. 1.3.1 Physical Models for Equivalent Circuit Elements. 1.3.2 Simple RC Circuits. 1.3.3 Analysis of Single Impedance Arcs. 1.4. Selected Applications of IS. Chapter 2. Theory (Ian D. Raistrick, Donald R. Franceschetti, and J. Ross Macdonald). 2.1. The Electrical Analogs of Physical and Chemical Processes. 2.1.1 Introduction. 2.1.2 The Electrical Properties of Bulk Homogeneous Phases. 2.1.2.1 Introduction. 2.1.2.2 Dielectric Relaxation in Materials with a Single Time Constant. 2.1.2.3 Distributions of Relaxation Times. 2.1.2.4 Conductivity and Diffusion in Electrolytes. 2.1.2.5 Conductivity and Diffusion-a Statistical Description. 2.1.2.6 Migration in the Absence of Concentration Gradients. 2.1.2.7 Transport in Disordered Media. 2.1.3 Mass and Charge Transport in the Presence of Concentration Gradients. 2.1.3.1 Diffusion. 2.1.3.2 Mixed Electronic-Ionic Conductors. 2.1.3.3 Concentration Polarization. 2.1.4 Interfaces and Boundary Conditions. 2.1.4.1 Reversible and Irreversible Interfaces. 2.1.4.2 Polarizable Electrodes. 2.1.4.3 Adsorption at the Electrode-Electrolyte Interface. 2.1.4.4 Charge Transfer at the Electrode-Electrolyte Interface. 2.1.5 Grain Boundary Effects. 2.1.6 Current Distribution, Porous and Rough Electrodes- the Effect of Geometry. 2.1.6.1 Current Distribution Problems. 2.1.6.2 Rough and Porous Electrodes. 2.2. Physical and Electrochemical Models. 2.2.1 The Modeling of Electrochemical Systems. 2.2.2 Equivalent Circuits. 2.2.2.1 Unification of Immitance Responses. 2.2.2.2 Distributed Circuit Elements. 2.2.2.3 Ambiguous Circuits. 2.2.3 Modeling Results. 2.2.3.1 Introduction. 2.2.3.2 Supported Situations. 2.2.3.3 Unsupported Situations: Theoretical Models. 2.2.3.4 Unsupported Situations: Equivalent Network Models. 2.2.3.5 Unsupported Situations: Empirical and Semiempirical Models. Chapter 3. Measuring Techniques and Data Analysis. 3.1. Impedance Measurement Techniques (Michael C. H. McKubre and Digby D. Macdonald). 3.1.1 Introduction. 3.1.2 Frequency Domain Methods. 3.1.2.1 Audio Frequency Bridges. 3.1.2.2 Transformer Ratio Arm Bridges. 3.1.2.3 Berberian-Cole Bridge. 3.1.2.4 Considerations of Potentiostatic Control. 3.1.2.5 Oscilloscopic Methods for Direct Measurement. 3.1.2.6 Phase-Sensitive Detection for Direct Measurement. 3.1.2.7 Automated Frequency Response Analysis. 3.1.2.8 Automated Impedance Analyzers. 3.1.2.9 The Use of Kramers-Kronig Transforms. 3.1.2.10 Spectrum Analyzers. 3.1.3 Time Domain Methods. 3.1.3.1 Introduction. 3.1.3.2 Analog-to-Digital (A/D) Conversion. 3.1.3.3 Computer Interfacing. 3.1.3.4 Digital Signal Processing. 3.1.4 Conclusions. 3.2. Commercially Available Impedance Measurement Systems (Brian Sayers). 3.2.1 Electrochemical Impedance Measurement Systems. 3.2.1.1 System Configuration. 3.2.1.2 Why Use a Potentiostat? 3.2.1.3 Measurements Using 2, 3 or 4-Terminal Techniques. 3.2.1.4 Measurement Resolution and Accuracy. 3.2.1.5 Single Sine and FFT Measurement Techniques. 3.2.1.6 Multielectrode Techniques. 3.2.1.7 Effects of Connections and Input Impedance. 3.2.1.8 Verification of Measurement Performance. 3.2.1.9 Floating Measurement Techniques. 3.2.1.10 Multichannel Techniques. 3.2.2 Materials Impedance Measurement Systems. 3.2.2.1 System Configuration. 3.2.2.2 Measurement of Low Impedance Materials. 3.2.2.3 Measurement of High Impedance Materials. 3.2.2.4 Reference Techniques. 3.2.2.5 Normalization Techniques. 3.2.2.6 High Voltage Measurement Techniques. 3.2.2.7 Temperature Control. 3.2.2.8 Sample Holder Considerations. 3.3. Data Analysis (J. Ross Macdonald). 3.3.1 Data Presentation and Adjustment. 3.3.1.1 Previous Approaches. 3.3.1.2 Three-Dimensional Perspective Plotting. 3.3.1.3 Treatment of Anomalies. 3.3.2 Data Analysis Methods. 3.3.2.1 Simple Methods. 3.3.2.2 Complex Nonlinear Least Squares. 3.3.2.3 Weighting. 3.3.2.4 Which Impedance-Related Function to Fit? 3.3.2.5 The Question of "What to Fit" Revisited. 3.3.2.6 Deconvolution Approaches. 3.3.2.7 Examples of CNLS Fitting. 3.3.2.8 Summary and Simple Characterization Example. Chapter 4. Applications of Impedance Spectroscopy. 4.1. Characterization of Materials (N. Bonanos, B. C. H. Steele, and E. P. Butler). 4.1.1 Microstructural Models for Impedance Spectra of Materials. 4.1.1.1 Introduction. 4.1.1.2 Layer Models. 4.1.1.3 Effective Medium Models. 4.1.1.4 Modeling of Composite Electrodes. 4.1.2 Experimental Techniques. 4.1.2.1 Introduction. 4.1.2.2 Measurement Systems. 4.1.2.3 Sample Preparation-Electrodes. 4.1.2.4 Problems Associated With the Measurement of Electrode Properties. 4.1.3 Interpretation of the Impedance Spectra of Ionic Conductors and Interfaces. 4.1.3.1 Introduction. 4.1.3.2 Characterization of Grain Boundaries by IS. 4.1.3.3 Characterization of Two-Phase Dispersions by IS. 4.1.3.4 Impedance Spectra of Unusual Two-phase Systems. 4.1.3.5 Impedance Spectra of Composite Electrodes. 4.1.3.6 Closing Remarks. 4.2. Characterization of the Electrical Response of High Resistivity Ionic and Dielectric Solid Materials by Immittance Spectroscopy (J. Ross Macdonald). 4.2.1 Introduction. 4.2.2 Types of Dispersive Response Models: Strengths and Weaknesses. 4.2.2.1 Overview. 4.2.2.2 Variable-slope Models. 4.2.2.3 Composite Models. 4.2.3 Illustration of Typical Data Fitting Results for an Ionic Conductor. 4.3. Solid State Devices (William B. Johnson and Wayne L. Worrell). 4.3.1 Electrolyte-Insulator-Semiconductor (EIS) Sensors. 4.3.2 Solid Electrolyte Chemical Sensors. 4.3.3 Photoelectrochemical Solar Cells. 4.3.4 Impedance Response of Electrochromic Materials and Devices (Gunnar A. Niklasson, Anna Karin Johsson, and Maria Stromme). 4.3.4.1 Introduction. 4.3.4.2 Materials. 4.3.4.3 Experimental Techniques. 4.3.4.4 Experimental Results on Single Materials. 4.3.4.5 Experimental Results on Electrochromic Devices. 4.3.4.6 Conclusions and Outlook. 4.3.5 Time-Resolved Photocurrent Generation (Albert Goossens). 4.3.5.1 Introduction-Semiconductors. 4.3.5.2 Steady-State Photocurrents. 4.3.5.3 Time-of-Flight. 4.3.5.4 Intensity-Modulated Photocurrent Spectroscopy. 4.3.5.5 Final Remarks. 4.4. Corrosion of Materials (Digby D. Macdonald and Michael C. H. McKubre). 4.4.1 Introduction. 4.4.2 Fundamentals. 4.4.3 Measurement of Corrosion Rate. 4.4.4 Harmonic Analysis. 4.4.5 Kramer-Kronig Transforms. 4.4.6 Corrosion Mechanisms. 4.4.6.1 Active Dissolution. 4.4.6.2 Active-Passive Transition. 4.4.6.3 The Passive State. 4.4.7 Point Defect Model of the Passive State (Digby D. Macdonald). 4.4.7.1 Introduction. 4.4.7.2 Point Defect Model. 4.4.7.3 Electrochemical Impedance Spectroscopy. 4.4.7.4 Bilayer Passive Films. 4.4.8 Equivalent Circuit Analysis (Digby D. Macdonald and Michael C. H. McKubre). 4.4.8.1 Coatings. 4.4.9 Other Impedance Techniques. 4.4.9.1 Electrochemical Hydrodynamic Impedance (EHI). 4.4.9.2 Fracture Transfer Function (FTF). 4.4.9.3 Electrochemical Mechanical Impedance. 4.5. Electrochemical Power Sources. 4.5.1 Special Aspects of Impedance Modeling of Power Sources (Evgenij Barsoukov). 4.5.1.1 Intrinsic Relation Between Impedance Properties and Power Sources Performance. 4.5.1.2 Linear Time-Domain Modeling Based on Impedance Models, Laplace Transform. 4.5.1.3 Expressing Model Parameters in Electrical Terms, Limiting Resistances and Capacitances of Distributed Elements. 4.5.1.4 Discretization of Distributed Elements, Augmenting Equivalent Circuits. 4.5.1.5 Nonlinear Time-Domain Modeling of Power Sources Based on Impedance Models. 4.5.1.6 Special Kinds of Impedance Measurement Possible with Power Sources-Passive Load Excitation and Load Interrupt. 4.5.2 Batteries (Evgenij Barsoukov). 4.5.2.1 Generic Approach to Battery Impedance Modeling. 4.5.2.2 Lead Acid Batteries. 4.5.2.3 Nickel Cadmium Batteries. 4.5.2.4 Nickel Metal-hydride Batteries. 4.5.2.5 Li-ion Batteries. 4.5.3 Impedance Behavior of Electrochemical Supercapacitors and Porous Electrodes (Brian E. Conway). 4.5.3.1 Introduction. 4.5.3.2 The Time Factor in Capacitance Charge or Discharge. 4.5.3.3 Nyquist (or Argand) Complex-Plane Plots for Representation of Impedance Behavior. 4.5.3.4 Bode Plots of Impedance Parameters for Capacitors. 4.5.3.5 Hierarchy of Equivalent Circuits and Representation of Electrochemical Capacitor Behavior. 4.5.3.6 Impedance and Voltammetry Behavior of Brush Electrode Models of Porous Electrodes. 4.5.3.7 Impedance Behavior of Supercapacitors Based on Pseudocapacitance. 4.5.3.8 Deviations of Double-layer Capacitance from Ideal Behavior: Representation by a Constant-phase Element (CPE). 4.5.4 Fuel Cells (Norbert Wagner). 4.5.4.1 Introduction. 4.5.4.2 Alkaline Fuel Cells (AFC). 4.5.4.3 Polymer Electrolyte Fuel Cells (PEFC). 4.5.4.4 Solid Oxide Fuel Cells (SOFC). Appendix. Abbreviations and Definitions of Models. References. Index.

5,212 citations

Journal ArticleDOI
TL;DR: In this article, a CO2-laser-based photoacoustic spectrometer was used to determine the temporal concentration profile of atmospheric ethene in Mexico City, and the results of this campaign were compared with data obtained in the winter of 2001.
Abstract: A CO2-laser-based photoacoustic spectrometer was used to determine the temporal concentration profile of atmospheric ethene in Mexico City. Ethene measurements were conducted at the facilities of our institute, which is located in the north of the city and next to an avenue with heavy traffic density. Ambient air from outside our laboratory was continuously pumped into the spectrometer. This campaign was performed for 24 h a day, from November 24–30, 2001. The maximum ethene levels ranged between 26 and 81 ppbV. As expected, the lowest concentrations were monitored on weekends. These data were analyzed in combination with ozone and nitrogen oxides profiles, which were permanently monitored by an air-pollution-monitoring government network. Information on the seasonal variability of ethene was obtained by comparing the results of this campaign with data obtained in the winter of 2001. In general, the ethene concentration in November was about 30% higher than in February. On weekdays, the mean dose of human...

3,242 citations

Journal ArticleDOI
TL;DR: In this article, a new analysis tool was developed to quantify the experimentally observed changes in morphology of portlandite, allowing the calculation of the relative surface energies of the crystal facets.

2,498 citations