scispace - formally typeset
Search or ask a question
Journal ArticleDOI

Biological and mechanical characterization of commercial and experimental periodontal surgical dressings.

TL;DR: In this article, the authors evaluated the biocompatibility and mechanical properties of two commercially available and one experimental periodontal dressing materials, including Periobond, Barricaid and Exothane 8 monomer.
Abstract: The objective of this study was to evaluate the biocompatibility and mechanical properties of two commercially available and one experimental periodontal dressing materials. The cytotoxicity of Periobond ® , Barricaid ® and one experimental periodontal dressing based on Exothane ® 8 monomer was tested on 3T3/NIH mouse fibroblast. Genotoxicity was assessed by micronuclei formation, and cell alterations were analyzed using light microscopy. Both biological assays were performed using the eluate obtained from specimens after 24, 72, or 168 hours of incubation. Mechanical characterization was assessed through the ultimate tensile strength and the water sorption and solubility tests. The significance level of α = 0.05 was used for all statistical analyses. All the materials promoted a cell viability lower than 60% in all evaluated times. In general, the cell viability was significantly reduced after 72 and 168h of specimens' incubation. Considering the factor material, there were not statistical differences in the cell viability (p = 0.156). The genotoxicity was not statistically significant among the groups in the different periods of time (p > 0.05). Differences in the ultimate tensile strength values were not statistically significant different among the groups (p = 0.125). Periobond ® showed the higher water sorption values (p < 0.001). Regarding solubility, there were no statistical differences between the groups (p = 0.098). All the periodontal dressing materials evaluated in this study exerted a cytotoxic effect against mouse fibroblasts, and their toxicity became more evident over time. Among the materials evaluated, the experimental light-cure type has shown overall similar properties to the commercial references.

Content maybe subject to copyright    Report

Citations
More filters
Journal ArticleDOI
TL;DR: Both HPdLF and hGF cells showed complete cell morbidity with zinc-oxide hydrogels, suggesting that zinc oxide-based gels in concentrations as low as 9% could be toxic intraorally to soft tissues that harbor gingival and periodontal ligament fibroblasts.
Abstract: ABSTRACT Hyaluronic acid (HA) is a naturally occurring biopolymer, with a remarkable wound healing property. Zinc-oxide non-eugenol is a material widely used for periodontal dressing in dentistry. However, it has been reported that zinc oxide non-eugenol is toxic to osteoblasts and fibroblasts. Hence, the present study aimed to evaluate the drug release and cytotoxicity of HA and zinc-oxide gels. Hydrogels of HA and zinc oxide were formulated with carbopol as a carrier. In vitro drug release was performed by UV spectrophotometry, dialysis, and vial bag methods. Cytotoxicity assessment of HA and zinc-oxide gels was performed in human periodontal ligament fibroblasts (HPdLF) and human gingival fibroblasts (hGFs). An inverted phase-contrast microscope was used to assess the morphological changes. At 24 and 48 hr, HPdLF cells showed the highest viability in 0.1% low molecular weight-HA (LMW-HA) with a median value of 131.9, and hGFs showed the highest viability in 5% LMW-HA with a median of 129.56. The highest viability of HPdLF cells was observed in 5% high molecular weight-HA (HMW-HA), with a median value of 127.11. hGFs showed the highest viability in 1% HMW-HA with a median value of 97.99. Within the limitations of the present study, we concluded that LMW-HA is more efficient than HMW-HA. Both HPdLF and hGF cells showed complete cell morbidity with zinc-oxide hydrogels. Therefore, zinc oxide-based gels in concentrations as low as 9% could be toxic intraorally to soft tissues that harbor gingival and periodontal ligament fibroblasts.

1 citations

References
More filters
Journal ArticleDOI
TL;DR: Dental polymer networks have been shown to be susceptible to hygroscopic and hydrolytic effects to varying extents dependent upon their chemistry and structure, and these effects on the clinical performance of polymer restoratives is largely unknown.

1,190 citations

Journal ArticleDOI
TL;DR: Gradual replacement of TEGDMA with UDMA or/and Bis-EMA (4) in copolymerization with Bis-GMA resulted in more flexible resins with lower water sorption and higher solubility values, depending on the T EGDMA content.

588 citations

Journal ArticleDOI
TL;DR: There was no cell type identified which was consistently less or more sensitive to the toxic effects of the tested compounds than the others, and for several of the highly cytotoxic composite components, less cytot toxic alternatives are available.
Abstract: It was the purpose of this investigation to determine the cytotoxic effects (ED50 concentrations) of 35 monomers or additives identified in commercial dental resin composites. Monolayers of permanent 3T3 cells and three primary human fibroblast types derived from oral tissues (gingiva, pulp, and periodontal ligament) were used as test systems. All substances were tested in concentrations ranging from 0.01 to 5.0 mM. In general, ED50 values varied from 0.06 to > 5 mM. Within the groups of co(monomers), initiators, and cointiators, severe (e.g., Bis-GMA, UDMA, DMBZ, and DMDTA) or moderate (HEMA, BEMA, CQ, DMPT, and DMAPE) cytotoxic effects could be evaluated. Within the group of reaction/decomposition products, only moderate or slight effects were found (ED50: 0.7 to > 5 mM). The inhibitor BHT, the contaminant TPSb, and the photostabilizer HMBP, however, were highly cytotoxic in all cell cultures. In addition, the ED50 values of DBPO and HMBP significantly varied (0.43-3.8 mM, respectively, and 0.44-3.07 mM) with the applied cell culture. Our comprehensive screening shows that for several of the highly cytotoxic composite components, less cytotoxic alternatives are available. Furthermore, there was no cell type identified which was consistently less or more sensitive to the toxic effects of the tested compounds than the others. Primary human periodontal ligament and pulp fibroblasts, however, were found to be more sensitive than 3T3 and gingival fibroblasts to alterations from most tested substances.

463 citations

Journal ArticleDOI
TL;DR: These Guidelines have been prepared to provide those new to the field and others engaged in teaching and instruction with the information necessary to increase their awareness of the problems and to enable them to deal with them effectively.
Abstract: Cell-line misidentification and contamination with microorganisms, such as mycoplasma, together with instability, both genetic and phenotypic, are among the problems that continue to affect cell culture. Many of these problems are avoidable with the necessary foresight, and these Guidelines have been prepared to provide those new to the field and others engaged in teaching and instruction with the information necessary to increase their awareness of the problems and to enable them to deal with them effectively. The Guidelines cover areas such as development, acquisition, authentication, cryopreservation, transfer of cell lines between laboratories, microbial contamination, characterisation, instability and misidentification. Advice is also given on complying with current legal and ethical requirements when deriving cell lines from human and animal tissues, the selection and maintenance of equipment and how to deal with problems that may arise.

350 citations

Journal ArticleDOI
TL;DR: Water sorption and solubility of six proprietary composite resin materials were assessed, and monomers eluted from the organic matrix during water storage identified, and triethyleneglycol dimethacrylate was the main monomer released.
Abstract: Water sorption and solubility of six proprietary composite resin materials were assessed, and monomers eluted from the organic matrix during water storage identified. Water sorption and solubility tests were carried out with the following storage times: 4 h, 24 h and 7, 60 and 180 days. After storage, water sorption and solubility were determined. Eluted monomers were analysed by high performance liquid chromatography (HPLC). Correlation between the retention time of the registered peak and the reference peak was observed, and UV-spectra confirmed the identity. The results showed an increase in water sorption until equilibrium for all materials with one exception. The solubility behaviour of the composite resin materials tested revealed variations, with both mass decrease and increase. The resin composition influences the water sorption and solubility behaviour of composite resin materials. The HPLC analysis of eluted components revealed that triethyleneglycol dimethacrylate (TEGDMA) was the main monomer released. Maximal monomer concentration in the eluate was observed after 7 days. During the test period, quantifiable quantities of urethanedimethacrylate (UEDMA) monomer were observed, whereas 2,2-bis[4-(2-hydroxy-3-methacryloyloxypropoxy)-phenyl]propane (Bis-GMA) was only found in detectable quantities. No detectable quantities of bisphenol-A were observed during the test period.

340 citations