scispace - formally typeset
Journal ArticleDOI

Chinaldinsäure als analytisches Reagens III

01 Nov 1938-Fresenius Journal of Analytical Chemistry (Springer-Verlag)-Vol. 115, Iss: 7, pp 265-268

...read more


Citations
More filters
Journal ArticleDOI

[...]

TL;DR: In this paper, the titrated zinc solution may contain an excess of Cd (85%), and the analysis with Ni or Co is very limited, with an error of ⩽ 1%.
Abstract: 0.001–0.005M solutions of zinc salts (1–5 mg Zn in io ml) which contain more than 95% of foreign metal as Mg, Ca, Ba, Mn.(II), Fc(III), Al or Cr(III), may be titrated hctcrometrically with an error of ⩽ 1%. The titrated zinc solution may contain an excess of Cd (85%). The analysis with Ni or Co is very limited.

24 citations

Journal ArticleDOI

[...]

Yvette Marin1, Clément Duval1
TL;DR: In this paper, auteurs ont prepared 67 precipites, i.e., gravimetriques, for effectuer le dosage gravimetrique du cuivre, and le thermobalance de Chevenard a permis de determiner les temperatures auxquelles il faut les porter pour obtenir un poids correct.
Abstract: Resume Les auteurs ont prepare 67 precipites proposes jusqu'ici pour effectuer le dosage gravimetrique du cuivre. Pour ces precipites, le thermobalance de Chevenard a permis de determiner les temperatures auxquelles il faut les porter pour obtenir un poids correct. Ces tempeeratures sont rassemblees dans le tableau ci-dessus qui contient aussi celles des methodes qu'ils jugent les meilleures pour faire le dosage automatique du metal. IIs ont etudie tout particulierement l'oxydation du metal divise ainsi que le comportement des corps a caractere basique qui conduisent a l'hydroxyde cuivrique. Ils eliminent un grand nombre de reactifs precipitants, soit parce que ceux-ci ne conduisent pas a des depots quantitatifs, soit parce qu'ils ne possedent pas les formules attribuees par leurs auteurs, soit parce que la courbe de thermolyse des precipites formes n'offre pas de palier horizontal. Par contre, le cupferron et le neocupferron fournissent avec le cuivre des complexes pouvant ^ utre portes jusqu'au voisinage de 100/dg; de la de nouvelles analyses gravimetriques. Un certain nombre d'erreurs ont ete relevees; ainsi, le sulfure cuivreux chauffee ne peut pas etre pese tel quel. Il se convertit, apres passage au sulfate, en oxyde cuivrique qui offre le meme pourcentage de cuivre. Les auteurs trouvent enfin une preparation simple pour le sulfure cuivrique precipite et pour le thiocyanate cuivrique qui etait jusqu'ici peu connu. L-e cuivre est un corps simple pour lequel on a propose le plus de reactifs gravimetriques, mais, notre etude critique permet de conclure qu'une douzaine seulement est acceptable et valable dans tous les cas pratiques.

12 citations

Journal ArticleDOI

[...]

TL;DR: In this article, a method for the micro-estimation of zinc by means of quinaldinic acid in the presence of copper, silver or mercury individually, or in the case of both silver and mercury, is described.
Abstract: A method for the micro-estimation of zinc by means of quinaldinic acid in the presence of copper, silver or mercury individually, or in the presence of both silver and mercury, is described. It depends upon the use of thiourea for masking the reaction of copper, mercury and silver ions with which it forms stable complexes in acid solution. In the case, where copper is present, a previous addition of sodium bisulphite is necessary to reduce the cupric to cuprous ion. Zinc is precipitated as usual in acetic acid solution by the addition of sodium quinaldinate.

10 citations

Journal ArticleDOI

[...]

TL;DR: Quinoxaline-2-carboxylic acid and 3-chloro and 3hydroxy derivatives have been studied as analytical reagents and the solubility products of the metal salts, the optimum pH range for complete precipitation and the thermal behaviours of metal complexes have been established as mentioned in this paper.
Abstract: Quinoxaline-2-carboxylic acid and 3-chloro and 3-hydroxy derivatives have been studied as analytical reagents. The solubility products of the metal salts, the optimum pH range for complete precipitation and the thermal behaviours of the metal complexes have been established. Quinoxaline-2-carboxylic acid allows the gravimetric determination of Cu(II), Cd(II), Zn(II), Co(II), Ni(II) and Pd(II); with the 3-chloro and 3-hydroxy derivatives, only palladium(II) could be precipitated quantitatively.

9 citations

Journal ArticleDOI

[...]

TL;DR: Etude pH-metrique de l'acide quinaldique as mentioned in this paper, Ka = 1,2 · 10−5, qH/Q−1 = 1.2
Abstract: Etude pH-metrique de l'acide quinaldique. Determination de la constante du couple acide/base (QH/Q−1), Ka = 1,2 · 10−5.

7 citations