scispace - formally typeset
Proceedings ArticleDOI

Design and implementation of a hand-to-hand multifrequency bioimpedance measurement scheme for Total Body Water estimation

Reads0
Chats0
TLDR
The design and implementation of a hand-to-hand bioimpedance spectrometer for TBW estimation which can measure impedances within the range of5.3 Ω to 5.3 kΩ in the β dispersion region of tissue between 500 Hz and 1 MHz is presented.
Abstract
Human body has an intricate regulatory mechanism to maintain the Total Body Water (TBW) content and thereby sustain normal hydration levels. However, chronic fluid variations can occur and are often associated with pathological conditions like renal insufficiency and/or medications. Hence, a sensitive and precise estimation of TBW is of much clinical significance. Recent years have seen the emergence of Bioimpedance Spectroscopy (BIS) as a potential tool for TBW estimation with a unique capacity to differentiate between the extracellular and intracellular water content. The design and implementation of a hand-to-hand bioimpedance spectrometer for TBW estimation which can measure impedances within the range of 5.3 Ω to 5.3 kΩ in the β dispersion region of tissue between 500 Hz and 1 MHz is presented in this paper. A three reference calibration algorithm based on quadratic Lagrange interpolation is employed in order to mathematically correct the systematic errors in the measurements. The Cole parameters are extracted from the calibrated spectroscopy measurements by applying a Non-Linear Least Square (NLLS) iterative fitting on the resistance spectrum and further used to determine the extracellular, intracellular and total body water content. Measurements are done on 18 subjects (9 males and 9 females, age 23.3 ± 2.5 years, mean ± SD) at 17 different frequencies within the range of 3 kHz to 1 MHz. TBW estimated using the implemented BIS device prototype is validated against an FDA approved segmental body composition monitor from TANITA. The estimates show a strong positive correlation with Pearson's r of 0.83. The Bland-Altman analysis done on two systems indicate a similarity in TBW estimations with a bias of only 0.17 L while the 95% limits of agreement lie between −6.47 L and 6.81 L.

read more

Citations
More filters
Journal ArticleDOI

Fundamentals, Recent Advances, and Future Challenges in Bioimpedance Devices for Healthcare Applications

TL;DR: The basis and fundamentals of bioimpedance measurements are described covering issues ranging from the hardware diagrams to the configurations and designs of the electrodes and from the mathematical models that describe the frequency behavior of the bioimpingance to the sources of noise and artifacts.
Journal ArticleDOI

Smart Bioimpedance Spectroscopy Device for Body Composition Estimation.

TL;DR: The results obtained in a validation study with respiratory patients show the accuracy and feasibility of the proposed technology for bioimpedance measurements, and a new algorithm for the identification of Cole model parameters, which is the basis of body composition estimation through bioIMpedance spectroscopy analysis.
References
More filters
Journal ArticleDOI

Understanding Bland Altman analysis

Davide Giavarina
- 05 Jun 2015 - 
TL;DR: The aim of this article is to provide guidance on the use and interpretation of Bland Altman analysis in method comparison studies.
Book

Human Body Composition

TL;DR: Part 1 Measurement and prediction methods: densitometry, S.B. Lukaski multicomponent molecular-level models of body composition analysis, and Influencing factors and relationships to disease: exercise training and body composition changes.
Journal ArticleDOI

Predicting body cell mass with bioimpedance by using theoretical methods: a technological review

TL;DR: Results add further support to the validity of the Hanai theory, the equation used, and the conclusion that ECW and ICW volume can be predicted by an approach based solely on fundamental principles.
Journal ArticleDOI

Body-composition assessment via air-displacement plethysmography in adults and children: a review.

TL;DR: This review reviewed the principal findings from studies published between December 1995 and August 2001 that compared the BOD POD method with reference methods and summarized factors contributing to the different study findings.
Journal ArticleDOI

New standards of weight and body composition by frame size and height for assessment of nutritional status of adults and the elderly.

TL;DR: It is recommended that assessment of anthropometric nutritional status and health status of contemporary adult and elderly populations be made with reference to the present standards in conjunction with age correction factors.
Related Papers (5)