Flexible Sensors for Biomedical Application

01 Jan 2018-pp 287-314
TL;DR: In this chapter, fundamental aspect of various sensing films and associated mechanism has been illustrated and state-of-the-art work on the promising flexible sensing platforms for biomedical applications is also discussed.
Abstract: The research paradigm for biosensing devices has been focussed to explore flexible sensors. Here, the term “flexible” is indicative of the substrate which has sufficient degree of deformability so that it could be suitably placed at any place. Advances in flexible sensing technologies can be observed by the number of smart products in the market as well as with the number of publications exponentially coming out every year in which diversified development in terms of device operation and performance have been explored. However, as is the case for most new developments, there are several challenges and opportunities which this relatively newfangled field is facing, both in the basic and applied aspects. These challenges and opportunities basically lie in three broad areas, namely design, fabrication, and integration of the developed flexible systems to improve the purpose-oriented sensing capabilities, such as sensing characteristics, functionality, so and so forth. In this chapter, fundamental aspect of various sensing films and associated mechanism has been illustrated. With this article, state-of-the-art work on the promising flexible sensing platforms for biomedical applications is also discussed.
Citations
More filters
Journal ArticleDOI
TL;DR: In this paper, a detailed discussion has been carried out to understand critical steps involved in the fabrication of the silicon-based MEMS resonator and some challenges starting from the materials' selection to the final phase of obtaining a compact MEMS resonance device for its fabrication have been explored critically.

16 citations

Journal ArticleDOI
TL;DR: A comprehensive review on present trend of research on MEMS-based pressure sensors, its applications and the research gap observed till date is presented along with the scope for future work, which has not been discussed in earlier reviews.
Abstract: Considering its vast utility in industries, this paper aims to present a detailed review on fundamentals, classification and progresses in pressure sensors, along with its wide area of applications, its design aspects and challenges, to provide state-of-the-art gist to the researchers of the similar domain at one place.,Swiftly emerging research prospects in the micro-electro-mechanical system (MEMS) enable to build complex and sophisticated micro-structures on a substrate containing moving masses, cantilevers, flexures, levers, linkages, dampers, gears, detectors, actuators and many more on a single chip. One of the MEMS initial products that emerged into the micro-system technology is MEMS pressure sensor. Because of their high performance, low cost and compact in size, these sensors are extensively being adopted in numerous applications, namely, aerospace, automobile and bio-medical domain, etc. These application requirements drive and impose tremendous conditions on sensor design to overcome the tedious design and fabrication procedure before its reality. MEMS-based pressure sensors enable a wide range of pressure measurement as per the application requirements.,The paper provides a detailed review on fundamentals, classification and progresses in pressure sensors, along with its wide area of applications, its design aspects and challenges, to provide state of the art gist to the researchers of the similar domain at one place.,The present paper discusses the basics of MEMS pressure sensors, their working principles, different design aspects, classification, type of sensing diaphragm used and illustration of various transduction mechanisms. Moreover, this paper presents a comprehensive review on present trend of research on MEMS-based pressure sensors, its applications and the research gap observed till date along with the scope for future work, which has not been discussed in earlier reviews.

15 citations

Journal ArticleDOI
TL;DR: In this article, the facile fabrication of graphite embedded polydimethylsiloxane (PDMS) composites using in-situ polymerization was reported and an extensive characterization was performed using scanning electron microscopy (SEM), contact angle measurement system, thermogravimetric analysis (TGA), and differential scanning calorimetry (DSC).
Abstract: This work reports the facile fabrication of graphite embedded polydimethylsiloxane (PDMS) composites using in-situ polymerization and investigates the impact of graphite fillers on their mechanical and thermal characteristics. The extensive characterization is performed using scanning electron microscopy (SEM), contact angle measurement system, thermogravimetric analysis (TGA), and differential scanning calorimetry (DSC). The mechanical properties of the prepared composites are investigated by compression test which explores the possibility of manipulating the PDMS properties by unswervingly modifying the concentration of conductive graphite filler which improves filler dispersion in the PDMS and increases its interaction with graphite fillers, thereby enhancing the mechanical and thermal characteristics of the manufactured composites. The current study confirms the hydrophobicity (contact angle ~112°) of the fabricated composites and investigates the impact of graphite concentrations ranging from 2.5%–20% on the mechanical properties of pure PDMS polymer during compression testing. Furthermore, the thermal conductivity, thermal diffusivity, and specific heat of graphite-embedded PDMS were around 82%, 505% and 1040% higher than that of the pure PDMS, respectively, while the mechanical properties for the compressive module ranged from 3.2 MPa to 4.9 MPa with the elastic behavior up to 40% strain.

13 citations

Journal ArticleDOI
TL;DR: In this article, the authors summarized the state-of-the-art research work carried out over nano functionalized paper-based analytical devices and associated challenges/solutions in the point of care testing domain.
Abstract: Over the last few years, the microfluidics phenomenon coupled with the Internet of Things (IoT) using innovative nano-functional materials has been recognized as a sustainable and economical tool for point-of-care testing (POCT) of various pathogens influencing human health. The sensors based on these phenomena aim to be designed for cost-effectiveness, make it handy, environment-friendly, and get an accurate, easy, and rapid response. Considering the burgeoning importance of analytical devices in the healthcare domain, this review paper is based on the gist of sensing aspects of the microfabricated paper-based analytical devices (μPADs). The article discusses the various used design methodologies and fabrication approaches and elucidates the recently reported surface modification strategies, detection mechanisms viz., colorimetric, electrochemical, fluorescence, electrochemiluminescence, etc. In a nutshell, this article summarizes the state-of-the-art research work carried out over the nano functionalized paper-based analytical devices and associated challenges/solutions in the point of care testing domain.

10 citations

Journal ArticleDOI
TL;DR: Flexible sensor technology has emerged as a promising and dynamic practice to collect important health information at a comparatively low cost in a reliable and user-friendly way to avoid adverse effects.
Abstract: As the highest percentage of global mortality is caused by several cardiovascular diseases (CVD), maintenance and monitoring of a healthy cardiovascular condition have become the primary concern of each and every individual. Simultaneously, recent progress and advances in wearable pressure sensor technology have provided many pathways to monitor and detect underlying cardiovascular illness in terms of irregularities in heart rate, blood pressure, and blood oxygen saturation. These pressure sensors can be comfortably attached onto human skin or can be implanted on the surface of vascular grafts for uninterrupted monitoring of arterial blood pressure. While the traditional monitoring systems are time-consuming, expensive, and not user-friendly, flexible sensor technology has emerged as a promising and dynamic practice to collect important health information at a comparatively low cost in a reliable and user-friendly way. This Review explores the importance and necessity of cardiovascular health monitoring while emphasizing the role of flexible pressure sensors in monitoring patients' health conditions to avoid adverse effects. A comprehensive discussion on the current research progress along with the real-time impact and accessibility of pressure sensors developed for cardiovascular health monitoring applications has been provided.

10 citations

References
More filters
Book
01 Jan 1983
TL;DR: This book describes the fundamental aspects of fluorescence, the biochemical applications of this methodology, and the instrumentation used in fluorescence spectroscopy.
Abstract: Fluorescence methods are being used increasingly in biochemical, medical, and chemical research. This is because of the inherent sensitivity of this technique. and the favorable time scale of the phenomenon of fluorescence. 8 Fluorescence emission occurs about 10- sec (10 nsec) after light absorp tion. During this period of time a wide range of molecular processes can occur, and these can effect the spectral characteristics of the fluorescent compound. This combination of sensitivity and a favorable time scale allows fluorescence methods to be generally useful for studies of proteins and membranes and their interactions with other macromolecules. This book describes the fundamental aspects of fluorescence. and the biochemical applications of this methodology. Each chapter starts with the -theoreticalbasis of each phenomenon of fluorescence, followed by examples which illustrate the use of the phenomenon in the study of biochemical problems. The book contains numerous figures. It is felt that such graphical presentations contribute to pleasurable reading and increased understand ing. Separate chapters are devoted to fluorescence polarization, lifetimes, quenching, energy transfer, solvent effects, and excited state reactions. To enhance the usefulness of this work as a textbook, problems are included which illustrate the concepts described in each chapter. Furthermore, a separate chapter is devoted to the instrumentation used in fluorescence spectroscopy. This chapter will be especially valuable for those perform ing or contemplating fluorescence measurements. Such measurements are easily compromised by failure to consider a number of simple principles."

28,073 citations

Journal ArticleDOI
TL;DR: Transparent, conducting spray-deposited films of single-walled carbon nanotubes are reported that can be rendered stretchable by applying strain along each axis, and then releasing this strain.
Abstract: Transparent films of carbon nanotubes can accommodate strains of up to 150% and demonstrate conductivities as high as 2,200 S cm−1 in the stretched state.

2,847 citations

Journal ArticleDOI
TL;DR: This communication describes a simple method for patterning paper to create well-defined, millimeter-sized channels, comprising hydrophilic paper bounded by hydrophobic polymer, that will become the basis for low-cost, portable, and technically simple multiplexed bioassays.
Abstract: This communication describes a simple method for patterning paper to create well-defined, millimeter-sized channels, comprising hydrophilic paper bounded by hydrophobic polymer. We believe that this type of patterned paper will become the basis for low-cost, portable, and technically simple multiplexed bioassays. We demonstrate this capability by the simultaneous detection of glucose and protein in 5 μL of urine. The assay system is small, disposable, easy to use (and carry), and requires no external equipment, reagents, or power sources. We believe this kind of system is attractive for uses in less-industrialized countries, in the field, or as an inexpensive alternative to more advanced technologies already used in clinical settings.[1-4] The analysis of biological fluids is necessary for monitoring the health of populations,[2] but these measurements are difficult to implement in remote regions such as those found in less-industrialized countries, in emergency situations, or in home health-care settings.[3] Conventional laboratory instruments provide quantitative measurements of biological samples, but they are unsuitable for these situations since they are large, expensive, and require trained personnel and considerable volumes of biological samples.[2] Other bioassay platforms provide alternatives to more expensive instruments,[5-7] but the need remains for a platform that uses small volumes of sample and that is sufficiently inexpensive to be used widely for measuring samples from large populations. We believe that paper may serve as a particularly convenient platform for running bioassays in the remote situations locations. As a prototype for a mthod we believe to be particularly promosing, we patterned photoresist onto chromatography paper to form defined areas of hydrophilic paper separated by hydrophobic lines or “walls”; these patterns provide spatial control of biological fluids and enable fluid transport, without pumping, due to capillary action in the millimeter-sized channels produced. This method for patterning paper makes it possible to run multiple diagnostic assays on one strip of paper, while still using only small volumes of a single sample. In a fully developed technology, patterned photoresist would be replaced by an appropriate printing technology, but patterning paper with photoresist is: i) convenient for prototyping these devices, and ii) a useful new micropatterning technology in its own right. We patterned chromatography paper with SU-8 2010 photoresist as shown in Figure 1a and as described below: we soaked a 7.5-cm diameter piece of chromatography paper in 2 mL of SU-8 2010 for 30 s, spun it at 2000 rpm for 30 s, and then baked it at 95 °C for 5 min to remove the cyclopentanone in the SU-8 formula. We then exposed the photoresist and paper to 405 nm UV light (50 mW/cm2) for 10 s through a photo-mask (CAD/Art Services, Inc.) that was aligned using a mask aligner (OL-2 Mask Aligner, AB-M, Inc). After exposure, we baked the paper a second time at 95 °C for 5 min to cross-link the exposed portions of the resist. The unpolymerized photoresist was removed by soaking the paper in propylene glycol monomethyl ether acetate (PGMEA) (5 min), and by washing the pattern with propan-2-ol (3 × 10 mL). The paper was more hydrophobic after it was patterned, presumably due to residual resist bound to the paper, so we exposed the entire surface to an oxygen plasma for 10 s at 600 millitorr (SPI Plasma-Prep II, Structure Probe, Inc) to increase the hydrophilicity of the paper (Figures 2a and 2b). Figure 1 Chromatography paper patterned with photoresist. The darker lines are cured photoresist; the lighter areas are unexposed paper. (a) Patterned paper after absorbing 5 μL of Waterman red ink by capillary action. The central channel absorbs the sample ... Figure 2 Assays contaminated with (a) dirt, (b) plant pollen, and (c) graphite powder. The pictures were taken before and after running an artificial urine solution that contained 550 mM glucose and 75 μM BSA. The particulates do not move up the channels ... The patterned paper can be derivatized for biological assays by adding appropriate reagents to the test areas (Figures 1b and ​and2b).2b). In this communication, we demonstrate the method by detecting glucose and protein,[8] but the surface should be suitable for measuring many other analytes as well.[7] The glucose assay is based on the enzymatic oxidation of iodide to iodine,[9] where a color change from clear to brown is associated with the presence of glucose.[10] The protein assay is based on the color change of tetrabromophenol blue (TBPB) when it ionizes and binds to proteins;[11] a positive result in this case is indicated by a color change from yellow to blue. For the glucose assay, we spotted 0.3 μL of a 0.6 M solution of potassium iodide, followed by 0.3 μL of a 1:5 horseradish peroxidase/glucose oxidase solution (15 units of protein per mL of solution). For the protein assay, we spotted 0.3 μL of a 250-mM citrate buffer (pH 1.8) in a well separate from the glucose assay, and then layered 0.3 μL of a 3.3 mM solution of tetrabromophenol blue (TBPB) in 95% ethanol over the citrate buffer. The spotted reagents were allowed to air dry at room temperature. This pre-loaded paper gave consistent results for the protein assay regardless of storage temperature and time (when stored for 15 d both at 0 °C and at 23 °C, wrapped in aluminum foil). The glucose assay was sensitive to storage conditions, and showed decreased signal for assays run 24 h after spotting the reagents (when stored at 23 °C); when stored at 0 °C, however, the glucose assay was as sensitive after day 15 as it was on day 1. We measured artificial samples of glucose and protein in clinically relevant ranges (2.5-50 mM for glucose and 0.38-7.5 μM for bovine serum albumin (BSA))[12, 13] by dipping the bottom of each test strip in 5 μL of a pre-made test solution (Figure 2d). The fluid filled the entire pattern within ca. one minute, but the assays required 10-11 min for the paper to dry and for the color to fully develop.[14] In all cases, we observed color changes corresponding roughly in intensity to the amount of glucose and protein in the test samples, where the lowest concentrations define the lower limits to which these assays can be used (Figure 2e). For comparison, commercially-available dipsticks detect glucose at concentrations as low as 5 mM[7, 9] and protein as low as 0.75 μM;[6, 15] these limits indicate that these paper-based assays are comparable in sensitivity to commercial dipstick assays. Our assay format also allows for the measurement of multiple analytes. This paper-based assay is suitable for measuring multiple samples in parallel and in a relatively short period of time. For example, in one trial, one researcher was able to run 20 different samples (all with 550 mM glucose and 75 μM BSA) within 7.5 min (followed by another 10.5 min for the color to fully develop). An 18-min assay of this type—one capable of measuring two analytes in 20 different sample—may be efficient enough to use in high-throughput screens of larger sample pools. In the field, samples will not be measured under sterile conditions, and dust and dirt may contaminate the assays. The combination of paper and capillary action provides a mechanism for separating particulates from a biological fluid. As a demonstration, we purposely contaminated the artificial urine samples with quantities of dirt, plant pollen, and graphite powder at levels higher than we might expect to see in the samples in the field. These particulates do not move up the channels under the action of capillary wicking, and do not interfere with the assay (Figure 3). Paper strips have been used in biomedical assays for decades because they offer an inexpensive platform for colorimetric chemical testing.[1] Patterned paper has characteristics that lead to miniaturized assays that run by capillary action (e.g., without external pumping), with small volumes of fluids. These methods suggest a path for the development of simple, inexpensive, and portable diagnostic assays that may be useful in remote settings, and in particular, in less-industrialized countries where simple assays are becoming increasingly important for detecting disease and monitoring health,[16, 17], for environmental monitoring, in veterinary and agricultural practice and for other applications.

2,580 citations

Journal ArticleDOI
TL;DR: An efficient, low-cost fabrication strategy to construct a highly sensitive, flexible pressure sensor by sandwiching ultrathin gold nanowire-impregnated tissue paper between two thin polydimethylsiloxane sheets is reported, enabling facile large-area integration and patterning for mapping spatial pressure distribution.
Abstract: Flexible electronics hold great promise for wearable biomedical sensors. Here, the authors report a pressure sensor composed of gold nanowire-impregnated tissue paper, sandwiched between polydimethylsiloxane sheets, and demonstrate that the design is appropriate for large-area flexible electronics.

1,678 citations

Book
08 Mar 2013
TL;DR: Capillarity: Unconstrained Interfaces / Capillarity and gravity / Hysteresis and Elasticity of Triple Lines / Wetting and Long-Range Forces b/ Hydrodynamics of Interfaces -- Thin Films, Waves, and Ripples as discussed by the authors.
Abstract: Capillarity: Unconstrained Interfaces / Capillarity and Gravity / Hysteresis and Elasticity of Triple Lines / Wetting and Long-Range Forces b/ Hydrodynamics of Interfaces -- Thin Films, Waves, and Ripples / Dynamics of the Triple Line / Dewetting / Surfactants / Special Interfaces / Transport Phenomena