scispace - formally typeset
Search or ask a question
Journal ArticleDOI

Impact of final stent dimensions on long-term results following sirolimus-eluting stent implantation: serial intravascular ultrasound analysis from the sirius trial.

TL;DR: In this SIRIUS IVUS substudy, SES reduced both biologic variability and restenosis, resulting in increased predictability of long-term stent patency with postprocedure MSA.
About: This article is published in Journal of the American College of Cardiology.The article was published on 2004-06-02 and is currently open access. It has received 418 citations till now. The article focuses on the topics: Restenosis & Stent.
Citations
More filters
Journal ArticleDOI
TL;DR: Alice K. Jacobs, MD, FACC, FAHA, Chair Jeffrey L. Anderson, PhD, CCNS, CCRN, FAH, Chair-Elect - The first female FACC-FAHA board member to be elected in the history of the sport.
Abstract: Alice K. Jacobs, MD, FACC, FAHA, Chair Jeffrey L. Anderson, MD, FACC, FAHA, Chair-Elect Nancy Albert, PhD, CCNS, CCRN, FAHA Mark A. Creager, MD, FACC, FAHA Steven M. Ettinger, MD, FACC Robert A. Guyton, MD, FACC Jonathan L. Halperin, MD, FACC, FAHA Judith S. Hochman, MD, FACC, FAHA

3,040 citations


Cites background from "Impact of final stent dimensions on..."

  • ...Given improvements in technology and techniques, as well as recognition of the importance of an adequately deployed stent to decrease the risks of stent restenosis and thrombosis (12, 228, 229), the writing committee concluded that a minimum diameter stenosis of < 10% (with an optimal goal of as close to 0% as possible) should be the new benchmark for lesions treated with coronary stenting....

    [...]

Journal ArticleDOI
TL;DR: The medical profession should play a central role in evaluating the evidence related to drugs, devices, and procedures for the detection, management, and prevention of disease as mentioned in this paper, and when properly applied, expert analysis of available data on the benefits and risks of these therapies and procedures can

2,495 citations

Journal ArticleDOI
TL;DR: In this article, the predictors of stent thrombosis after sirolimus-eluting stent (SES) implantation were determined. But, their results were limited to 15 patients who developed STC after successful SES implantation.

719 citations

Journal ArticleDOI
TL;DR: Based upon the current available evidence, an algorithm for the treatment approaches to DES restenosis is proposed and its pattern is predominantly focal.

675 citations

Journal ArticleDOI
TL;DR: Elective stenting with IVUS guidance, especially in the placement of drug-eluting stent, may reduce the long-term mortality rate for unprotected left main coronary artery stenosis when compared with conventional angiography guidance.
Abstract: Background— Although intravascular ultrasound (IVUS) guidance has been useful in stenting for unprotected left main coronary artery stenosis, its impact on long-term mortality is still unclear. Methods and Results— In the MAIN-COMPARE registry, patients with unprotected left main coronary artery stenosis in a hemodynamically stable condition underwent elective stenting under the guidance of IVUS (756 patients) or conventional angiography (219 patients). Patients with acute myocardial infarction were excluded. The 3-year outcomes between the 2 groups were primarily compared using propensity-score matching in the entire and separate populations according to stent type. In 201 matched pairs of the overall population, there was a tendency of lower risk of 3-year morality with IVUS guidance compared with angiography guidance (6.0% versus 13.6%, log-rank P=0.063; hazard ratio, 0.54; 95% CI, 0.28 to 1.03; Cox-model P=0.061). In particular, in 145 matched pairs of patients receiving drug-eluting stent, the 3-year...

451 citations

References
More filters
Journal ArticleDOI
TL;DR: In this randomized clinical trial involving patients with complex coronary lesions, the use of a sirolimus-eluting stent had a consistent treatment effect, reducing the rates of restenosis and associated clinical events in all subgroups analyzed.
Abstract: Background Preliminary reports of studies involving simple coronary lesions indicate that a sirolimus-eluting stent significantly reduces the risk of restenosis after percutaneous coronary revascularization. Methods We conducted a randomized, double-blind trial comparing a sirolimus-eluting stent with a standard stent in 1058 patients at 53 centers in the United States who had a newly diagnosed lesion in a native coronary artery. The coronary disease in these patients was complex because of the frequent presence of diabetes (in 26 percent of patients), the high percentage of patients with longer lesions (mean, 14.4 mm), and small vessels (mean, 2.80 mm). The primary end point was failure of the target vessel (a composite of death from cardiac causes, myocardial infarction, and repeated percutaneous or surgical revascularization of the target vessel) within 270 days. Results The rate of failure of the target vessel was reduced from 21.0 percent with a standard stent to 8.6 percent with a sirolimus-eluting ...

4,271 citations

Journal ArticleDOI
TL;DR: As compared with a standard coronary stent, a sirolimus-eluting stent shows considerable promise for the prevention of neointimal proliferation, restenosis, and associated clinical events.
Abstract: BACKGROUND: The need for repeated treatment of restenosis of a treated vessel remains the main limitation of percutaneous coronary revascularization. Because sirolimus (rapamycin) inhibits the proliferation of lymphocytes and smooth-muscle cells, we compared a sirolimus-eluting stent with a standard uncoated stent in patients with angina pectoris. METHODS: We performed a randomized, double-blind trial to compare the two types of stents for revascularization of single, primary lesions in native coronary arteries. The trial included 238 patients at 19 medical centers. The primary end point was in-stent late luminal loss (the difference between the minimal luminal diameter immediately after the procedure and the diameter at six months). Secondary end points included the percentage of in-stent stenosis of the luminal diameter and the rate of restenosis (luminal narrowing of 50 percent or more). We also analyzed a composite clinical end point consisting of death, myocardial infarction, and percutaneous or surgical revascularization at 1, 6, and 12 months. RESULTS: At six months, the degree of neointimal proliferation, manifested as the mean (+/-SD) late luminal loss, was significantly lower in the sirolimus-stent group (-0.01+/-0.33 mm) than in the standard-stent group (0.80+/-0.53 mm, P<0.001). None of the patients in the sirolimus-stent group, as compared with 26.6 percent of those in the standard-stent group, had restenosis of 50 percent or more of the luminal diameter (P<0.001). There were no episodes of stent thrombosis. During a follow-up period of up to one year, the overall rate of major cardiac events was 5.8 percent in the sirolimus-stent group and 28.8 percent in the standard-stent group (P<0.001). The difference was due entirely to a higher rate of revascularization of the target vessel in the standard-stent group. CONCLUSIONS: As compared with a standard coronary stent, a sirolimus-eluting stent shows considerable promise for the prevention of neointimal proliferation, restenosis, and associated clinical events.

4,051 citations

Journal ArticleDOI
TL;DR: Late lumen loss and in-stent restenosis were the result of neointimal tissue proliferation, which tended to be uniformly distributed over the length of the stent.
Abstract: Background Studies have suggested that restenosis within Palmaz-Schatz stents results from neointimal hyperplasia or chronic stent recoil and occurs more frequently at the articulation. Methods and...

1,271 citations


"Impact of final stent dimensions on..." refers background in this paper

  • ...r e V p ( t s f p espite the widespread use of intracoronary stents, in-stent estenosis remains a major clinical problem (1,2)....

    [...]

Journal ArticleDOI
TL;DR: In this article, the safety and efficacy of sirolimus-coated BX Velocity stents were evaluated in 30 patients with angina pectoris electively treated with two different formulations of SIROlimuscoated stents (slow release and fast release).
Abstract: BACKGROUND: Restenosis remains an important limitation of interventional cardiology. Therefore, we aimed to determine the safety and efficacy of sirolimus (a cell-cycle inhibitor)-coated BX Velocity stents. METHODS AND RESULTS: Thirty patients with angina pectoris were electively treated with 2 different formulations of sirolimus-coated stents (slow release [SR], n=15, and fast release [FR], n=15). All stents were successfully delivered, and patients were discharged without clinical complications. Independent core laboratories analyzed angiographic and 3D volumetric intravascular ultrasound data (immediately after procedure and at 4-month follow-up). Eight-month clinical follow-up was obtained for all patients. There was minimal neointimal hyperplasia in both groups (11.0+/-3.0% in the SR group and 10.4+/-3.0% in the FR group, P:=NS) by ultrasound and quantitative coronary angiography (in-stent late loss, 0.09+/-0.3 mm [SR] and -0.02+/-0.3 mm [FR]; in-lesion late loss, 0.16+/-0.3 mm [SR] and -0.1+/-0.3 mm [FR]). No in-stent or edge restenosis (diameter stenosis >or=50%) was observed. No major clinical events (stent thrombosis, repeat revascularization, myocardial infarction, or death) had occurred by 8 months. CONCLUSIONS: The implantation of sirolimus-coated BX Velocity stents is feasible and safe and elicits minimal neointimal proliferation. Additional placebo-controlled trials are required to confirm these promising results.

833 citations

Journal ArticleDOI
TL;DR: This study demonstrates a sustained suppression of neointimal proliferation by sirolimus-eluting Bx VELOCITY stents 1 year after implantation.
Abstract: BACKGROUND: We have previously reported a virtual absence of neointimal hyperplasia 4 months after implantation of sirolimus-eluting stents. The aim of the present investigation was to determine whether these results are sustained over a period of 1 year. METHODS AND RESULTS: Forty-five patients with de novo coronary disease were successfully treated with the implantation of a single sirolimus-eluting Bx VELOCITY stent in Sao Paulo, Brazil (n=30, 15 fast release [group I, GI] and 15 slow release [GII]) and Rotterdam, The Netherlands (15 slow release, GIII). Angiographic and volumetric intravascular ultrasound (IVUS) follow-up was obtained at 4 and 12 months (GI and GII) and 6 months (GIII). In-stent minimal lumen diameter and percent diameter stenosis remained essentially unchanged in all groups (at 12 months, GI and GII; at 6 months, GIII). Follow-up in-lesion minimal lumen diameter was 2.28 mm (GIII), 2.32 mm (GI), and 2.48 mm (GII). No patient approached the >/=50% diameter stenosis at 1 year by angiography or IVUS assessment, and no edge restenosis was observed. Neointimal hyperplasia, as detected by IVUS, was virtually absent at 6 months (2+/-5% obstruction volume, GIII) and at 12 months (GI=2+/-5% and GII=2+/-3%). CONCLUSIONS: This study demonstrates a sustained suppression of neointimal proliferation by sirolimus-eluting Bx VELOCITY stents 1 year after implantation.

695 citations

Related Papers (5)