Implementation of the cloud-based computerized interpretation system in a nationwide lung cancer screening with low-dose CT: comparison with the conventional reading system

01 Jan 2021-European Radiology (Springer Berlin Heidelberg)-Vol. 31, Iss: 1, pp 475-485
TL;DR: Implementation of CAD and semi-automated measurement for lung nodules in a nationwide lung cancer screening program resulted in increased number of detected nodules and reduced variability in positive rates across institutions and computer-aided CT reading reduced inter-institutional variability.
Abstract: We aimed to compare the CT interpretation before and after the implementation of a computerized system for lung nodule detection and measurements in a nationwide lung cancer screening program. Our screening program started in April 2017, with 14 participating institutions. Initially, all CTs were interpreted using interpretation systems in each institution and manual nodule measurement (conventional system). A cloud-based CT interpretation system, equipped with semi-automated measurement and CAD (computer-aided detection) for lung nodules (cloud-based system), was implemented during the project. Positive rates and performances for lung cancer diagnosis based on the Lung-RADS version 1.0 were compared between the conventional and cloud-based systems. A total of 1821 (M:F = 1782:39, mean age 62.7 years, 16 confirmed lung cancers) and 4666 participants (M:F = 4560:106, mean age 62.8 years, 31 confirmed lung cancers) were included in the conventional and cloud-based systems, respectively. Significantly more nodules were detected in the cloud-based system (0.76 vs. 1.07 nodule/participant, p < .001). Positive rate did not differ significantly between the two systems (9.9% vs. 11.0%, p = .211), while their variability across institutions was significantly lower in the cloud-based system (coefficients of variability, 0.519 vs. 0.311, p = .018). The Lung-RADS-based sensitivity (93.8% vs. 93.5%, p = .979) and specificity (90.9% vs. 89.6%, p = .132) did not differ significantly between the two systems. Implementation of CAD and semi-automated measurement for lung nodules in a nationwide lung cancer screening program resulted in increased number of detected nodules and reduced variability in positive rates across institutions. • Computer-aided CT reading detected more lung nodules than radiologists alone in lung cancer screening. • Positive rate in lung cancer screening did not change with computer-aided reading. • Computer-aided CT reading reduced inter-institutional variability in lung cancer screening.
Citations
More filters
Journal ArticleDOI
TL;DR: Considerable variability existed in the interpretation of screening LDCT among radiologists partly from the different usage of the computerized system, and a retrospective reading of low-dose chest CTs in the central laboratory resulted in reduced variability but an increased positive rate.
Abstract: To evaluate the degree of variability in computer-assisted interpretation of low-dose chest CTs (LDCTs) among radiologists in a nationwide lung cancer screening (LCS) program, through comparison with a retrospective interpretation from a central laboratory. Consecutive baseline LDCTs (n = 3353) from a nationwide LCS program were investigated. In the institutional reading, 20 radiologists in 14 institutions interpreted LDCTs using computer-aided detection and semi-automated segmentation systems for lung nodules. In the retrospective central review, a single radiologist re-interpreted all LDCTs using the same system, recording any non-calcified nodules ≥ 3 mm without arbitrary rejection of semi-automated segmentation to minimize the intervention of radiologist’s discretion. Positive results (requiring additional follow-up LDCTs or diagnostic procedures) were initially classified by the lung CT screening reporting and data system (Lung-RADS) during the interpretation, while the classifications based on the volumetric criteria from the Dutch-Belgian lung cancer screening trial (NELSON) were retrospectively applied. Variabilities in positive rates were assessed with coefficients of variation (CVs). In the institutional reading, positive rates by the Lung-RADS ranged from 7.5 to 43.3%, and those by the NELSON ranged from 11.4 to 45.0% across radiologists. The central review exhibited higher positive rates by Lung-RADS (20.0% vs. 27.3%; p < .001) and the NELSON (23.1% vs. 37.0%; p < .001), and lower inter-institution variability (CV, 0.30 vs. 0.12, p = .003 by Lung-RADS; CV, 0.25 vs. 0.12, p = .014 by the NELSON) compared to the institutional reading. Considerable inter-institution variability in the interpretation of LCS results is caused by different usage of the computer-assisted system. • Considerable variability existed in the interpretation of screening LDCT among radiologists partly from the different usage of the computerized system. • A retrospective reading of low-dose chest CTs in the central laboratory resulted in reduced variability but an increased positive rate.

8 citations


Cites methods from "Implementation of the cloud-based c..."

  • ...In addition, the utilization of CAD for the interpretation may also increase the lung nodule detection and the positive rate [34]....

    [...]

Journal ArticleDOI
TL;DR: Focusing on the curation of data sets and algorithm development that allow for comparisons at different points will be required to advance the range of relevant tasks covered by future AI-enabled FDA-cleared devices.
Abstract: The use of artificial intelligence (AI) has grown dramatically in the past few years in the United States and worldwide, with more than 300 AI-enabled devices approved by the U.S. Food and Drug Administration (FDA). Most of these AI-enabled applications focus on helping radiologists with detection, triage, and prioritization of tasks by using data from a single point, but clinical practice often encompasses a dynamic scenario wherein physicians make decisions on the basis of longitudinal information. Unfortunately, benchmark data sets incorporating clinical and radiologic data from several points are scarce, and, therefore, the machine learning community has not focused on developing methods and architectures suitable for these tasks. Current AI algorithms are not suited to tackle key image interpretation tasks that require comparisons to previous examinations. Focusing on the curation of data sets and algorithm development that allow for comparisons at different points will be required to advance the range of relevant tasks covered by future AI-enabled FDA-cleared devices.

7 citations

Journal ArticleDOI
TL;DR: In this paper, the authors explored the optimum diameter threshold for solid nodules to define positive results at baseline screening low-dose CT (LDCT) and compared two-dimensional and volumetric measurement of lung nodules for the diagnosis of lung cancers.
Abstract: To explore the optimum diameter threshold for solid nodules to define positive results at baseline screening low-dose CT (LDCT) and to compare two-dimensional and volumetric measurement of lung nodules for the diagnosis of lung cancers. We included consecutive participants from the Korean Lung Cancer Screening project between 2017 and 2018. The average transverse diameter and effective diameter (diameter of a sphere with the same volume) of lung nodules were measured by semi-automated segmentation. Diagnostic performances for lung cancers diagnosed within 1 year after LDCT were evaluated using area under receiver-operating characteristic curves (AUCs), sensitivities, and specificities, with diameter thresholds for solid nodules ranging from 6 to 10 mm. The reduction of unnecessary follow-up LDCTs and the diagnostic delay of lung cancers were estimated for each threshold. Fifty-two lung cancers were diagnosed among 10,424 (10,141 men; median age 62 years) participants within 1 year after LDCT. Average transverse (0.980) and effective diameters (0.981) showed similar AUCs (p = .739). Elevating the average transverse diameter threshold from 6 to 9 mm resulted in a significantly increased specificity (91.7 to 96.7%, p < .001), a modest reduction in sensitivity (96.2 to 94.2%, p = .317), a 60.2% estimated reduction of unnecessary follow-up LDCTs, and a diagnostic delay in 1.9% of lung cancers. Elevating the threshold to 10 mm led to a significant reduction in sensitivity (86.5%, p = .025). Elevating the diameter threshold for solid nodules from 6 to 9 mm may lead to a substantial reduction in unnecessary follow-up LDCTs with a small proportion of diagnostic delay of lung cancers. • Elevation of the diameter threshold for solid nodules from 6 to 9 mm can substantially reduce unnecessary follow-up LDCTs with a small proportion of diagnostic delay of lung cancers. • The average transverse and effective diameters of lung nodules showed similar performances for the prediction of a lung cancer diagnosis.

5 citations

Journal ArticleDOI
TL;DR: In this paper , the authors review options for more rapid diagnosis of lung cancer at an earlier stage, thereby improving survival, including screening, allowing general practitioners to refer patients directly to low-dose computed tomography scan instead of a chest X-ray and the abolition of the "visitation filter", i.e. hospital doctors' ability to reject referrals from general practitioners without prior discussion with the referring doctor.
Abstract: • In the last 30 years, the prognosis for lung cancer patients has improved only moderately in Denmark. • X-rays of the thorax often delay the diagnosis of lung cancer and worsen the prognosis and should be replaced with low-dose CT if there is only a minor suspicion of lung cancer (the 3rd diagnostic track). • By allowing the GP to be referred for low-dose CT of the thorax in the 3rd diagnostic track, contact will be made with many of the persons whom the screenings do not capture. The purpose of this article is to review options for more rapid diagnosis of lung cancer at an earlier stage, thereby improving survival. These options include screening, allowing general practitioners to refer patients directly to low-dose computed tomography scan instead of a chest X-ray and the abolition of the "visitation filter", i.e. hospital doctors’ ability to reject referrals from general practitioners without prior discussion with the referring doctor.

3 citations

Journal ArticleDOI
TL;DR: In this paper , a meta-analysis of 2898 available subsolid nodules in the literature was performed, and the pooled incidence of growth was as high as 22%, with a 26% incidence reported for pure ground-glass nodules.
Abstract: Abstract Objectives To calculate the pooled incidence of interval growth after long-term follow-up and identify predictors of interval growth in subsolid nodules (SSNs) on chest CT. Methods A search of MEDLINE (PubMed), Cochrane Library, Web of Science Core Collection, and Embase was performed on November 08, 2021, for relevant studies. Patient information, CT scanner, and SSN follow-up information were extracted from each included study. A random-effects model was applied along with subgroup and meta-regression analyses. Study quality was assessed by the Newcastle–Ottawa scale, and publication bias was assessed by Egger’s test. Results Of the 6802 retrieved articles, 16 articles were included and analyzed, providing a total of 2898 available SSNs. The pooled incidence of growth in the 2898 SSNs was 22% (95% confidence interval [CI], 15–29%). The pooled incidence of growth in the subgroup analysis of pure ground-glass nodules was 26% (95% CI: 12–39%). The incidence of SSN growth after 2 or more years of stability was only 5% (95% CI: 3–7%). An initially large SSN size was found to be the most frequent risk factor affecting the incidence of SSN growth and the time of growth. Conclusions The pooled incidence of SSN growth was as high as 22%, with a 26% incidence reported for pure ground-glass nodules. Although the incidence of growth was only 5% after 2 or more years of stability, long-term follow-up is needed in certain cases. Moreover, the initial size of the SSN was the most frequent risk factor for growth. Key Points • Based on a meta-analysis of 2898 available subsolid nodules in the literature, the pooled incidence of growth was 22% for all subsolid nodules and 26% for pure ground-glass nodules. • After 2 or more years of stability on follow-up CT, the pooled incidence of subsolid nodule growth was only 5%. • Given the incidence of subsolid nodule growth, management of these lesions with long-term follow-up is preferred.

3 citations

References
More filters
Journal ArticleDOI
TL;DR: Screening with the use of low-dose CT reduces mortality from lung cancer, as compared with the radiography group, and the rate of death from any cause was reduced.
Abstract: Background The aggressive and heterogeneous nature of lung cancer has thwarted efforts to reduce mortality from this cancer through the use of screening. The advent of low-dose helical computed tomography (CT) altered the landscape of lung-cancer screening, with studies indicating that low-dose CT detects many tumors at early stages. The National Lung Screening Trial (NLST) was conducted to determine whether screening with low-dose CT could reduce mortality from lung cancer. Methods From August 2002 through April 2004, we enrolled 53,454 persons at high risk for lung cancer at 33 U.S. medical centers. Participants were randomly assigned to undergo three annual screenings with either low-dose CT (26,722 participants) or single-view posteroanterior chest radiography (26,732). Data were collected on cases of lung cancer and deaths from lung cancer that occurred through December 31, 2009. Results The rate of adherence to screening was more than 90%. The rate of positive screening tests was 24.2% with low-dose CT and 6.9% with radiography over all three rounds. A total of 96.4% of the positive screening results in the low-dose CT group and 94.5% in the radiography group were false positive results. The incidence of lung cancer was 645 cases per 100,000 person-years (1060 cancers) in the low-dose CT group, as compared with 572 cases per 100,000 person-years (941 cancers) in the radiography group (rate ratio, 1.13; 95% confidence interval [CI], 1.03 to 1.23). There were 247 deaths from lung cancer per 100,000 person-years in the low-dose CT group and 309 deaths per 100,000 person-years in the radiography group, representing a relative reduction in mortality from lung cancer with low-dose CT screening of 20.0% (95% CI, 6.8 to 26.7; P=0.004). The rate of death from any cause was reduced in the low-dose CT group, as compared with the radiography group, by 6.7% (95% CI, 1.2 to 13.6; P=0.02). Conclusions Screening with the use of low-dose CT reduces mortality from lung cancer. (Funded by the National Cancer Institute; National Lung Screening Trial ClinicalTrials.gov number, NCT00047385.).

7,710 citations

Journal ArticleDOI
TL;DR: Although lung cancer screening is not an alternative to smoking cessation, the USPSTF found adequate evidence that annual screening for lung cancer with LDCT in a defined population of high-risk persons can prevent a substantial number of lung cancerrelated deaths.
Abstract: The USPSTF now recommends annual screening for lung cancer with low-dose computed tomography in adults aged 55 to 80 years who have a 30 pack-year smoking history and currently smoke or have quit w...

2,164 citations

Journal ArticleDOI
TL;DR: In this trial involving high-risk persons, lung-cancer mortality was significantly lower among those who underwent volume CT screening than among thoseWho underwent no screening.
Abstract: Background There are limited data from randomized trials regarding whether volume-based, low-dose computed tomographic (CT) screening can reduce lung-cancer mortality among male former and...

1,502 citations

Journal ArticleDOI
TL;DR: Among subjects at high risk for lung cancer who were screened in three rounds of CT scanning and in whom noncalcified pulmonary nodules were evaluated according to volume and volume-doubling time, the chances of finding lung cancer 1 and 2 years after a negative first-round test were 1 in 1000 and 3 in 1000, respectively.
Abstract: BACKGROUND: The use of multidetector computed tomography (CT) in lung-cancer screening trials involving subjects with an increased risk of lung cancer has highlighted the problem for the clinician of deciding on the best course of action when noncalcified pulmonary nodules are detected by CT. METHODS: A total of 7557 participants underwent CT screening in years 1, 2, and 4 of a randomized trial of lung-cancer screening. We used software to evaluate a noncalcified nodule according to its volume or volume-doubling time. Growth was defined as an increase in volume of at least 25% between two scans. The first-round screening test was considered to be negative if the volume of a nodule was less than 50 mm3, if it was 50 to 500 mm3 but had not grown by the time of the 3-month follow-up CT, or if, in the case of those that had grown, the volume-doubling time was 400 days or more. RESULTS: In the first and second rounds of screening, 2.6% and 1.8% of the participants, respectively, had a positive test result. In round one, the sensitivity of the screen was 94.6% (95% confidence interval [CI], 86.5 to 98.0) and the negative predictive value 99.9% (95% CI, 99.9 to 100.0). In the 7361 subjects with a negative screening result in round one, 20 lung cancers were detected after 2 years of follow-up. CONCLUSIONS: Among subjects at high risk for lung cancer who were screened in three rounds of CT scanning and in whom noncalcified pulmonary nodules were evaluated according to volume and volume-doubling time, the chances of finding lung cancer 1 and 2 years after a negative first-round test were 1 in 1000 and 3 in 1000, respectively. (Current Controlled Trials number, ISRCTN63545820.). Copyright