scispace - formally typeset
Journal ArticleDOI

Influence of thermally aged barrier on corona discharge activity in transformer oil under AC voltages

Reads0
Chats0
TLDR
In this article, thermally aged oil impregnated pressboard insulation, as barrier, have high impact on CIV and breakdown voltage, and the injected current due to corona activity, its rise time, measured using HFCT, in the negative and positive half cycle of the AC voltage measured to be 600 ps and 500 ps respectively.
Abstract
Corona Inception voltage (CIV) / breakdown voltage increases when the barrier is placed anywhere from needle tip to the 20% of the needle-plane electrode gap above which a marginal reduction in breakdown voltage is observed but its value is much higher than the breakdown strength of the electrode gap without barrier. Thermally aged oil impregnated pressboard insulation, as barrier, have high impact on CIV and breakdown voltage. The injected current due to corona activity, its rise time, measured using HFCT, in the negative and positive half cycle of the AC voltage measured to be 600 ps and 500 ps respectively. The shape of the current pulse is the same with the aged pressboard insulation barrier in the electrode gap. The corona inception voltage was measured by using UHF sensor and the signal has frequency contents between 0.5 -2.2 GHz. The surface charge measurements indicates that the amount of charge accumulated is high with thermally aged oil impregnated pressboard (OIP) than the unused material. Polarity of surface charge acquired by OIP due to corona charging depends on the surface condition of the material. To understand the mechanical behavior of the aged specimen, tensile test and flexural test were carried out and could conclude that ageing of material reduces the fundamental mechanical properties of the material. SEM analysis indicates that scission of fibers occurs due to thermal ageing at high temperatures. Partial Discharge studies on corona activity indicate, on corona inception, discharges occur near peak of the applied AC voltage, irrespective of position of barrier. The phase width of the PD generated due to corona discharge activity is slightly high with thermally aged specimen compared with unused specimen.

read more

Citations
More filters
Journal ArticleDOI

A Review of Knowledge-Based Defect Identification via PRPD Patterns in High Voltage Apparatus

TL;DR: In this article, the authors reviewed the research progress of PD in high voltage apparatus, including motors and generators, cables, transformers and gas insulated equipment, with attempts to assess the severity of different types of PD initiating defects as well as key PD features that can be selected for classifying defects.
Journal ArticleDOI

Understanding the influence of ambience on thermal ageing of natural ester liquid

TL;DR: In this article, phase-resolved partial discharge analysis carried out using UHF signal indicates that corona discharges occur at the peak of the voltage waveform, while the magnitude of discharges is less in thermally aged liquid but the number of discharging increases.
Journal ArticleDOI

Effects of ambient humidity and thermal aging on properties of Nomex insulation in mining dry-type transformer

TL;DR: In this paper, the effect of ambient humidity and thermal aging on the properties of Nomex paper was analyzed for turning-to-turn insulation material of mining dry-type transformers.
Journal ArticleDOI

Breakdown and streamer behavior in double-layer oil-paper insulation under impulses of varying front time

TL;DR: In this article, the breakdown and streamer behavior in double-layer oil-paper insulation under impulses of varying front time were investigated to determine the pre-breakdown process in oil paper insulation and the relationships between front times and breakdown characteristics were investigated and impulse-polarity-dependent variations were observed.
Journal ArticleDOI

Understanding the Impact of Corona Aging of Ester Oil Adopting Fluorescent Technique

TL;DR: In this paper, the effects of electrical aging on ester oil in the presence of pressboard as a barrier between high voltage and ground electrode is studied, and a fluorescence-based analysis is used to obtain the fluorescence data as 3D excitation emission matrix.
References
More filters
Journal ArticleDOI

The excitation of UHF signals by partial discharges in GIS

TL;DR: In this article, the fundamental theory of the UHF method for detecting partial discharge (PD) in gas insulated substations (GIS) is presented, and the effects of position, size, current amplitude, and pulse shape of the PD source on the signal can be predicted using this theory.
Journal ArticleDOI

Propagation and structure of streamers in liquid dielectrics

TL;DR: In this article, the authors present a critical review of the current understanding of streamer propagation in dielectric liquids in order to help define the direction of future research, and they show that the molecular structure has a significant effect on streamers propagation.
Journal ArticleDOI

Bringing an insulation to failure: the role of space charge

TL;DR: The goal is to show how much space charge can contribute directly or indirectly, through local electric field magnification or alteration, to increase ageing rate or even trigger more energetic, thus faster, degradation processes in insulation design and electrical apparatus long-term performance/reliability.
Book

Transformer Engineering: Design, Technology, and Diagnostics, Second Edition

TL;DR: Transformer Engineering: Design, Technology, and Diagnostics, Second Edition as discussed by the authors helps to design better transformers, apply advanced numerical field computations more effectively, and tackle operational and maintenance issues.
Related Papers (5)