TLDR
In this article, the performance of shunt active filter for extracting the current references under steady and transient for both balanced and unbalanced conditions by using PI controller has been evaluated and wide-ranging simulations are carried out with PI controller for p q control strategy.
Abstract
By using a bulky amount of non-linear loads, power electronic equipments, commercial and even residential electrical equipments are causing deterioration of the quality of the electric supply through distortion of supply voltage. This will lead to development of more stringent requirements regarding harmonic current generation, which are found in IEEE519 and IEC61000. The active filters have been used to frontier the flow of harmonic currents in both transmission and distribution systems. But the presentation of the active power filter seems with various control strategies. This article gives the in depth analysis to evaluate the performance of shunt active filter for extracting the current references under steady and transient for both balanced and unbalanced conditions by using PI controller. The instantaneous real active and reactive power control strategy which is widely used in shunt active filter. The wide-ranging simulations are carried out with PI controller for p q control strategy for various voltage conditions.

read more

Citations
More filters

Simulasi filter aktif cascaded multilevel inverter untuk meminimalisir harmonisa pada motor induksi 3 fasa

TL;DR: Pengoperasian beban non-linear dapat menimbulkan permasalahan dalam sistem kelistrikan yaitu menghasilkan harmonisa ying daganggu kualitas daya.
Proceedings ArticleDOI

Harmonic Mitigation Using Shunt Active Power Filter Under Various Loading Condition

TL;DR: The proposed p-q theory control strategy with PI controller and hysteresis controller for extraction of the current reference signal for SAPF is able to achieve better optimum total harmonic distortion (THD) and has been validated using numerical results, which justifies the extensibility of the strategy.
References
More filters
Journal ArticleDOI

Harmonic and reactive power compensation based on the generalized instantaneous reactive power theory for three-phase four-wire systems

TL;DR: In this article, a generalized theory of instantaneous reactive power for three-phase power systems is proposed, which is valid for sinusoidal or nonsinusoidal and balanced or unbalanced systems with or without zero-sequence currents and/or voltages.
Journal ArticleDOI

A new power line conditioner for harmonic compensation in power systems

TL;DR: In this paper, a power line conditioner consisting of two small rating series active filters and a shunt passive filter is proposed to reduce voltage distortion at the connection point, and eliminate harmonic currents escaping into the system upstream of the connection points.
Journal ArticleDOI

A New Method to Eliminate AC Harmonic Currents by Magnetic Flux Compensation-Considerations on Basic Design

TL;DR: In this article, a new method of eliminating ac harmonic current is proposed, which is based on the principle of the magnetic flux compensation in a transformer core, by means of the new method, abnormal harmonics as well as normal harmonics can effectively be dealt with.
Proceedings ArticleDOI

Comparison of two compensation control strategies for SHAF in 3ph 4wire system by using PI controller

TL;DR: In this paper, a detailed analysis to compare and elevate the performance of two control strategies for extracting reference currents of shunt active filters under balanced, unbalanced and non-sinusoidal conditions by using PI controller is presented.