scispace - formally typeset
Search or ask a question
Journal ArticleDOI

J. Appl. Cryst.の発刊に際して

10 Mar 1970-Vol. 12, Iss: 1, pp 1-1
About: The article was published on 1970-03-10 and is currently open access. It has received 8159 citations till now.
Citations
More filters
Journal ArticleDOI
TL;DR: This paper could serve as a general literature citation when one or more of the open-source SH ELX programs (and the Bruker AXS version SHELXTL) are employed in the course of a crystal-structure determination.
Abstract: An account is given of the development of the SHELX system of computer programs from SHELX-76 to the present day. In addition to identifying useful innovations that have come into general use through their implementation in SHELX, a critical analysis is presented of the less-successful features, missed opportunities and desirable improvements for future releases of the software. An attempt is made to understand how a program originally designed for photographic intensity data, punched cards and computers over 10000 times slower than an average modern personal computer has managed to survive for so long. SHELXL is the most widely used program for small-molecule refinement and SHELXS and SHELXD are often employed for structure solution despite the availability of objectively superior programs. SHELXL also finds a niche for the refinement of macromolecules against high-resolution or twinned data; SHELXPRO acts as an interface for macromolecular applications. SHELXC, SHELXD and SHELXE are proving useful for the experimental phasing of macromolecules, especially because they are fast and robust and so are often employed in pipelines for high-throughput phasing. This paper could serve as a general literature citation when one or more of the open-source SHELX programs (and the Bruker AXS version SHELXTL) are employed in the course of a crystal-structure determination.

81,116 citations


Cites background from "J. Appl. Cryst.の発刊に際して"

  • ...These days such padding is less desirable and there are excellent programs such as enCIFer (Allen et al., 2004) for working with CIF files, so CIFTAB is now effectively redundant....

    [...]

Journal ArticleDOI
TL;DR: The goals of the PDB are described, the systems in place for data deposition and access, how to obtain further information and plans for the future development of the resource are described.
Abstract: The Protein Data Bank (PDB; http://www.rcsb.org/pdb/ ) is the single worldwide archive of structural data of biological macromolecules. This paper describes the goals of the PDB, the systems in place for data deposition and access, how to obtain further information, and near-term plans for the future development of the resource.

34,239 citations


Cites methods from "J. Appl. Cryst.の発刊に際して"

  • ...This dictionary contains among oth i ems descriptions of the solution components, the experime conditions, enumerated lists of the instruments used, as we information about structure refinement....

    [...]

Journal ArticleDOI
TL;DR: New features added to the refinement program SHELXL since 2008 are described and explained.
Abstract: The improvements in the crystal structure refinement program SHELXL have been closely coupled with the development and increasing importance of the CIF (Crystallographic Information Framework) format for validating and archiving crystal structures. An important simplification is that now only one file in CIF format (for convenience, referred to simply as `a CIF') containing embedded reflection data and SHELXL instructions is needed for a complete structure archive; the program SHREDCIF can be used to extract the .hkl and .ins files required for further refinement with SHELXL. Recent developments in SHELXL facilitate refinement against neutron diffraction data, the treatment of H atoms, the determination of absolute structure, the input of partial structure factors and the refinement of twinned and disordered structures. SHELXL is available free to academics for the Windows, Linux and Mac OS X operating systems, and is particularly suitable for multiple-core processors.

28,425 citations


Cites methods from "J. Appl. Cryst.の発刊に際して"

  • ...Multithreading is achieved using OpenMP along the lines suggested by Diederichs (2000), and the program is particularly suitable for multiple-core processors....

    [...]

Journal ArticleDOI
TL;DR: CCP4mg is a project that aims to provide a general-purpose tool for structural biologists, providing tools for X-ray structure solution, structure comparison and analysis, and publication-quality graphics.
Abstract: CCP4mg is a project that aims to provide a general-purpose tool for structural biologists, providing tools for X-ray structure solution, structure comparison and analysis, and publication-quality graphics. The map-fitting tools are available as a stand-alone package, distributed as `Coot'.

27,505 citations


Cites background or methods from "J. Appl. Cryst.の発刊に際して"

  • ...…e-mail: emsley@ysbl.york.ac.uk # 2004 International Union of Crystallography Printed in Denmark ± all rights reserved CCP4mg is a project that aims to provide a general-purpose tool for structural biologists, providing tools for X-ray structure solution, structure comparison and…...

    [...]

  • ...The introduction of FRODO (Jones, 1978) and then O (Jones et al., 1991) to the ®eld of protein crystallography was in each case revolutionary, each in their time breaking new ground in demonstrating what was possible with the current hardware....

    [...]

Journal ArticleDOI
TL;DR: The PHENIX software for macromolecular structure determination is described and its uses and benefits are described.
Abstract: Macromolecular X-ray crystallography is routinely applied to understand biological processes at a molecular level. How­ever, significant time and effort are still required to solve and complete many of these structures because of the need for manual interpretation of complex numerical data using many software packages and the repeated use of interactive three-dimensional graphics. PHENIX has been developed to provide a comprehensive system for macromolecular crystallo­graphic structure solution with an emphasis on the automation of all procedures. This has relied on the development of algorithms that minimize or eliminate subjective input, the development of algorithms that automate procedures that are traditionally performed by hand and, finally, the development of a framework that allows a tight integration between the algorithms.

18,531 citations


Cites methods from "J. Appl. Cryst.の発刊に際して"

  • ...After ensuring that the diffraction data are sound and understood, the next critical necessity for solving a structure is the determination of phases using one of several strategies (Adams, Afonine et al., 2009)....

    [...]

  • ...Tools such as efficient rigid-body refinement (multiplezones algorithm; Afonine et al., 2009), simulated-annealing refinement (Brünger et al., 1987) in Cartesian or torsion-angle space (Grosse-Kunstleve et al., 2009), automatic NCS detection and its use as restraints in refinement are important at…...

    [...]

References
More filters
Journal ArticleDOI
TL;DR: A systematic test shows how ARP/wARP deals with automated model building for structures that have been solved by molecular replacement.
Abstract: Automatic iterative model (re-)building, as implemented in ARP/wARP and its new control system flex-wARP, is particularly well suited to follow structure solution by molecular replacement. More than 100 molecular-replacement solutions automatically solved by the BALBES software were submitted to three standard protocols in flex-wARP and the results were compared with final models from the PDB. Standard metrics were gathered in a systematic way and enabled the drawing of statistical conclusions on the advantages of each protocol. Based on this analysis, an empirical estimator was proposed that predicts how good the final model produced by flex-wARP is likely to be based on the experimental data and the quality of the molecular-replacement solution. To introduce the differences between the three flex-wARP protocols (keeping the complete search model, converting it to atomic coordinates but ignoring atom identities or using the electron-density map calculated from the molecular-replacement solution), two examples are also discussed in detail, focusing on the evolution of the models during iterative rebuilding. This highlights the diversity of paths that the flex-wARP control system can employ to reach a nearly complete and accurate model while actually starting from the same initial information.

153 citations

Journal ArticleDOI
TL;DR: The optimal strategy for collecting X-ray diffraction data from macromolecular crystals is discussed and the quality, or information content, of the recorded intensities of these measured reflections is discussed.
Abstract: The optimal strategy for collecting X-ray diffraction data from macromolecular crystals is discussed. Two kinds of factors influencing the completeness of data are considered. The first are geometric, arising from the symmetry of the reciprocal lattice and from the experimental setup; they affect quantitatively the completeness of the measured set of reflections. The second concern the quality, or information content, of the recorded intensities of these measured reflections.

153 citations

Journal ArticleDOI
TL;DR: A program, MASSHA, for three-dimensional rendering and rigid-body refinement of the quaternary structure of macromolecular complexes, which allows display and manipulation of high-resolution atomic structures and low-resolution models represented as smooth envelopes or ensembles of beads.
Abstract: A program, MASSHA, for three-dimensional rendering and rigid-body refinement is presented. The program allows display and manipulation of high-resolution atomic structures and low-resolution models represented as smooth envelopes or ensembles of beads. MASSHA is coupled with a computational module to align structural models of different nature and resolution automatically. The main feature is the possibility for rigid-body refinement of the quaternary structure of macromolecular complexes. If high- or low-resolution models of individual subunits are available, the complex can be constructed on the computer display and refined to fit the experimental solution scattering data. MASSHA provides both interactive and automated refinement modes to position subunits in a heterodimeric complex (general case) and in a homodimeric complex with a twofold symmetry axis. Examples of application of the program (running on IBM PC compatible machines under Windows 9x/NT/2000) are given.

153 citations

Journal ArticleDOI
TL;DR: Improvements over the previous versions that facilitate the refinement of macromolecular structures against neutron data are included and a list of restraints for H-atom refinement is included.
Abstract: Some of the improvements in SHELX2013 make SHELXL convenient to use for refinement of macromolecular structures against neutron data without the support of X-ray data. The new NEUT instruction adjusts the behaviour of the SFAC instruction as well as the default bond lengths of the AFIX instructions. This work presents a protocol on how to use SHELXL for refinement of protein structures against neutron data. It includes restraints extending the Engh & Huber [Acta Cryst. (1991), A47, 392–400] restraints to H atoms and discusses several of the features of SHELXL that make the program particularly useful for the investigation of H atoms with neutron diffraction. SHELXL2013 is already adequate for the refinement of small molecules against neutron data, but there is still room for improvement, like the introduction of chain IDs for the refinement of macromolecular structures.

153 citations

Journal ArticleDOI
TL;DR: This paper compares a number of docking tools for their performance in cognate re-docking (pose prediction) and/or virtual screening using a variety of ligand-based approaches.
Abstract: The recent literature is replete with papers evaluating computational tools (often those operating on 3D structures) for their performance in a certain set of tasks. Most commonly these papers compare a number of docking tools for their performance in cognate re-docking (pose prediction) and/or virtual screening. Related papers have been published on ligand-based tools: pose prediction by conformer generators and virtual screening using a variety of ligand-based approaches. The reliability of these comparisons is critically affected by a number of factors usually ignored by the authors, including bias in the datasets used in virtual screening, the metrics used to assess performance in virtual screening and pose prediction and errors in crystal structures used.

152 citations