Proceedings ArticleDOI

Low voltage fault ride through criteria for grid connection of wind turbine generators

28 May 2008-pp 1-4
TL;DR: In this paper, the performance of grid-connected wind-turbine generators in case of system faults, i.e. short-circuits, the so-called lowvoltage-fault-ride-throughconditions (LVFRT-conditions), is analyzed.
Abstract: This paper deals with the performance of grid-connected wind-turbine generators in case of system faults, i.e. short-circuits, the so-called low-voltage-fault-ride-through-conditions (LVFRT-conditions). Furthermore the requirements of frequency, voltage and reactive power control are explained. The conditions are defined in the grid-codes of the utilities even in Europe in a different way, leading to contra dictionary operating conditions in the interconnected UCTE-system. The increasing importance of electricity generation by wind turbines in the future requires similar and standardized operating criteria for all countries.
Citations
More filters
Journal ArticleDOI
TL;DR: In this article, the authors provide an overview of grid code technical requirements regarding the connection of large wind farms to the electric power systems, including active and reactive power regulation, voltage and frequency operating limits and wind farm behaviour during grid disturbances.
Abstract: This paper provides an overview of grid code technical requirements regarding the connection of large wind farms to the electric power systems. The grid codes examined are generally compiled by transmission system operators (TSOs) of countries or regions with high wind penetration and therefore incorporate the accumulated experience after several years of system operation at significant wind penetration levels. The paper focuses on the most important technical requirements for wind farms, included in most grid codes, such as active and reactive power regulation, voltage and frequency operating limits and wind farm behaviour during grid disturbances. The paper also includes a review of modern wind turbine technologies, regarding their capability of satisfying the requirements set by the codes, demonstrating that recent developments in wind turbine technology provide wind farms with stability and regulation capabilities directly comparable to those of conventional generating plants.

1,331 citations


Cites background from "Low voltage fault ride through crit..."

  • ...Reference [18] compares the requirements appearing in the grid codes of Germany, Denmark, Spain, Great Britain, Canada and USA....

    [...]

Journal ArticleDOI
TL;DR: In this paper, a superconducting fault-current limiter-magnetic energy storage system is presented to solve weak lowvoltage ride-through capability and fluctuating output power in doubly fed induction generators.
Abstract: Two major problems that are faced by doubly fed induction generators are: weak low-voltage ride-through capability and fluctuating output power. To solve these problems, a superconducting fault-current limiter-magnetic energy storage system is presented. The superconducting coil (SC) is utilized as the energy storage device for output power smoothing control during normal operation and as a fault-current limiting inductor to limit the surge current in the stator or rotor during the grid fault. The SC can also weaken the rotor back electromotive force voltage, and thus enhance the controllability of the rotor-side converter (RSC), which helps to protect both the RSC and the gearbox. Simulation results verify the efficacy of the proposed approaches.

150 citations

Journal ArticleDOI
TL;DR: This study analyzes the inverter circuit control requirements during normal operation and grid fault ride-through and proposes a distributed controller design to allow inverter modules to operate independently of each other.
Abstract: Modular generator and converter topologies are being pursued for large offshore wind turbines to achieve fault tolerance and high reliability. A centralized controller presents a single critical point of failure which has prevented a truly modular and fault-tolerant system from being obtained. This study analyzes the inverter circuit control requirements during normal operation and grid fault ride-through and proposes a distributed controller design to allow inverter modules to operate independently of each other. All the modules independently estimate the grid voltage magnitude and position, and the modules are synchronized together over a controller area network (CAN) bus. The CAN bus is also used to interleave the pulsewidth modulation switching of the modules and synchronize the analog to digital converter (ADC) sampling. The controller structure and algorithms are tested by laboratory experiments with respect to normal operation, initial synchronization to the grid, module fault tolerance, and grid fault ride-through.

136 citations


Cites background from "Low voltage fault ride through crit..."

  • ...The turbine must also further ride through for 3 min at 85% of nominal voltage and indefinitely at 90% of nominal voltage [27]....

    [...]

Proceedings ArticleDOI
21 Oct 2010
TL;DR: In this paper, a three-phase-four-wire grid-tied solar inverter is described and necessary changes to the control such as positive (PS), negative (NS) and zero sequence (ZS) separation, a stable phase-locked-loop (PLL) as well as voltage support by means of reactive current as well and stress factors to the hardware will be identified.
Abstract: Distributed power generation systems (DPGS) such as wind and solar become more and more widely spread. As a consequence grid operating companies demand system services. As part of the general fault ride through (FRT) requirements this paper deals with low voltage ride through (LVRT) capability of a three-phase-four-wire grid-tied solar inverter. The standard system will be described and necessary changes to the control such as positive (PS), negative (NS) and zero sequence (ZS) separation, a stable phase-locked-loop (PLL) as well as voltage support by means of reactive current as well as stress factors to the hardware will be identified.

93 citations

Journal ArticleDOI
TL;DR: The resistive value of the SFCL as well as the superconducting coil inductance of the SMES are simultaneously optimized so that a sudden increase in the kinetic energy in the DFIG rotor during faults, an initial stored energy inThe SMES coil, an energy loss of theSFCL, and an output power fluctuation of the D FIG are minimum.
Abstract: This paper deals with a cooperative control of a resistive type superconducting fault current limiter (SFCL) and a superconducting magnetic energy storage (SMES) for enhancing fault ride through (FRT) capability and smoothing power fluctuation of the doubly fed induction generator (DFIG)-based wind farm. When the system faults occur, the SFCL is used to limit the fault current, alleviate the terminal voltage drop, and transient power fluctuation so that the DFIG can ride through the fault. Subsequently, the remaining power fluctuation is suppressed by the SMES. The resistive value of the SFCL as well as the superconducting coil inductance of the SMES are simultaneously optimized so that a sudden increase in the kinetic energy in the DFIG rotor during faults, an initial stored energy in the SMES coil, an energy loss of the SFCL, and an output power fluctuation of the DFIG are minimum. The superior control effect of the cooperative SFCL and SMES over the individual device is confirmed by simulation study.

85 citations


Cites methods from "Low voltage fault ride through crit..."

  • ...According to the grid code of USA AWEA, the wind turbine must withstand 15% of voltage dip at the connection point with duration of up to 625 ms [12]....

    [...]

References
More filters
Journal ArticleDOI
TL;DR: In this article, the authors argue that photovoltaics and renewable energies are growing at a much faster pace than the rest of the economy in Europe and worldwide and that renewable energy sources for the generation of heat and the use of environment friendly biofuels for the transport sector will become more and more important in the future.
Abstract: Photovoltaics and renewable energies are growing at a much faster pace than the rest of the economy in Europe and worldwide. This and the dramatic oil price increases in 2005 have led to a remarkable re-evaluation of the renewable energy sector by politics and financing institutions. Despite the fact that there are still discrepancies between the European Union and the USA, as to how to deal with climate change, renewable energies will play an important role for the implementation of the Kyoto Protocol and the worldwide introduction of tradable Green Certificates. Apart from the electricity sector, renewable energy sources for the generation of heat and the use of environment friendly biofuels for the transport sector will become more and more important in the future.

203 citations

Journal ArticleDOI
TL;DR: In this paper, the authors proposed a methodology for harmonization based on a feed-in law with a modular and transparent premium for renewable electricity producers, which considers technology costs, some grid services, political incentives and national priorities.

87 citations

Journal ArticleDOI
TL;DR: In this paper, the authors briefly define distributed resources (DR) and discuss the current status of DR. The main focus is on discussing the value DR can provide to re-regulated electricity markets.

69 citations