scispace - formally typeset
Open AccessJournal Article

On implant surfaces: a review of current knowledge and opinions.

Reads0
Chats0
TLDR
It was noted that these novel implant surfaces all had particular nanoroughness structures that were not present in their respective predecessors; this finding was suggested as a possible common mechanism behind the demonstrated stronger bone responses to these implants compared to adequate controls.
Abstract
The aims of the present review are (1) to identify essential surface parameters; (2) to present an overview of surface characteristics at the micrometer and nanometer levels of resolution relevant for the four most popular oral implant systems; (3) to discuss potential advantages of nanoroughness, hydrophilicity, and biochemical bonding; and (4) to suggest a hypothetical common mechanism behind strong bone responses to novel implant surfaces from different commercial companies. Oral implants from four major companies varied in average surface roughness (Sa) from 0.3 to 1.78 microm and in the developed surface area ratio (Sdr) from 24% to 143%, with the smoothest implants originating from Biomet 3i and the roughest from Institut Straumann. The original Branemark turned, machined surface had an Sa of 0.9 microm and an Sdr of 34%, making it clearly rougher than the smoothest implants examined. When evaluated for nanometer roughness, there was a substantial variation in Sa in the different implants from the four major companies. Novel implants from Biomet 3i, AstraTech, and Straumann differed from their respective predecessors in microroughness, physicochemical properties, and nano_roughness. When examined with scanning electron microscopy at high magnification, it was noted that these novel implant surfaces all had particular nanoroughness structures that were not present in their respective predecessors; this finding was suggested as a possible common mechanism behind the demonstrated stronger bone responses to these implants compared to adequate controls.

read more

Citations
More filters
Journal ArticleDOI

A review on the wettability of dental implant surfaces II: Biological and clinical aspects

TL;DR: This review provides a general overview of the available information about the contact angle values of experimental and of marketed implant surfaces, some of the techniques used to modify surface wettability of implants, and results from in vitro and clinical studies.
Journal ArticleDOI

Implant biomaterials: A comprehensive review.

TL;DR: Various dental bio-materials which were used in the past and as well as the latest material used now are summarized.
Journal ArticleDOI

Modern implant dentistry based on osseointegration: 50 years of progress, current trends and open questions.

TL;DR: This volume of Periodontology 2000 reviews the progress of implant therapy over the past 50 years, including the basics of implant surgery required to achieve osseointegration on a predictable basis and evolving innovations, and some of the hottest controversies are discussed.
Journal ArticleDOI

Influence of implant surfaces on osseointegration

TL;DR: The literature on dental implant surfaces is reviewed by assessing in vitro and in vivo studies to show the current perspective of implant development and the perspective of incorporating biomimetic molecules to the implant surface and their effects on bone formation and remodeling around implants are discussed.
Journal ArticleDOI

Smoking and dental implants: A systematic review and meta-analysis

TL;DR: The insertion of implants in smokers significantly affected the failure rates, the risk of postoperative infection, and marginal bone loss for smokers versus non-smokers against the alternative hypothesis of a difference.
References
More filters
Journal Article

The long-term efficacy of currently used dental implants: a review and proposed criteria of success.

TL;DR: Criteria for the evaluation of dental implant success are proposed and an attempt has been made to standardize the basis for comments on each type of implant.
Journal ArticleDOI

Enhanced Bone Apposition to a Chemically Modified SLA Titanium Surface

TL;DR: It is concluded that the modSLA surface promoted enhanced bone apposition during early stages of bone regeneration, as compared with a standard SLA surface.
Journal Article

Oral implant surfaces: Part 1--review focusing on topographic and chemical properties of different surfaces and in vivo responses to them.

TL;DR: Modately roughened surfaces seem to have some clinical advantages over smoother or rougher surfaces, but the differences are small and often not statistically significant.
Journal ArticleDOI

High surface energy enhances cell response to titanium substrate microstructure.

TL;DR: Osteoblasts grown on modified Ti surfaces exhibited a more differentiated phenotype characterized by increased alkaline phosphatase activity and osteocalcin and generated an osteogenic microenvironment through higher production of PGE2 and TGF-beta1 and 1alpha,25OH2D3 increased these effects in a manner that was synergistic with high surface energy.
Journal ArticleDOI

Ultrasound-guided percutaneous injection of ethanolamine oleate for hypersplenism. An experimental study in dogs.

TL;DR: In order to evaluate a possible therapy for hypersplenism, an experiment with animals was done and 0.6 ml/kg body weight of 5% ethanolamine oleate was injected percutaneously into the spleen under ultrasound guidance.
Related Papers (5)