Patterned Paper as a Platform for Inexpensive, Low‐Volume, Portable Bioassays

12 Feb 2007-Angewandte Chemie (NIH Public Access)-Vol. 46, Iss: 8, pp 1318-1320
TL;DR: This communication describes a simple method for patterning paper to create well-defined, millimeter-sized channels, comprising hydrophilic paper bounded by hydrophobic polymer, that will become the basis for low-cost, portable, and technically simple multiplexed bioassays.
Abstract: This communication describes a simple method for patterning paper to create well-defined, millimeter-sized channels, comprising hydrophilic paper bounded by hydrophobic polymer. We believe that this type of patterned paper will become the basis for low-cost, portable, and technically simple multiplexed bioassays. We demonstrate this capability by the simultaneous detection of glucose and protein in 5 μL of urine. The assay system is small, disposable, easy to use (and carry), and requires no external equipment, reagents, or power sources. We believe this kind of system is attractive for uses in less-industrialized countries, in the field, or as an inexpensive alternative to more advanced technologies already used in clinical settings.[1-4] The analysis of biological fluids is necessary for monitoring the health of populations,[2] but these measurements are difficult to implement in remote regions such as those found in less-industrialized countries, in emergency situations, or in home health-care settings.[3] Conventional laboratory instruments provide quantitative measurements of biological samples, but they are unsuitable for these situations since they are large, expensive, and require trained personnel and considerable volumes of biological samples.[2] Other bioassay platforms provide alternatives to more expensive instruments,[5-7] but the need remains for a platform that uses small volumes of sample and that is sufficiently inexpensive to be used widely for measuring samples from large populations. We believe that paper may serve as a particularly convenient platform for running bioassays in the remote situations locations. As a prototype for a mthod we believe to be particularly promosing, we patterned photoresist onto chromatography paper to form defined areas of hydrophilic paper separated by hydrophobic lines or “walls”; these patterns provide spatial control of biological fluids and enable fluid transport, without pumping, due to capillary action in the millimeter-sized channels produced. This method for patterning paper makes it possible to run multiple diagnostic assays on one strip of paper, while still using only small volumes of a single sample. In a fully developed technology, patterned photoresist would be replaced by an appropriate printing technology, but patterning paper with photoresist is: i) convenient for prototyping these devices, and ii) a useful new micropatterning technology in its own right. We patterned chromatography paper with SU-8 2010 photoresist as shown in Figure 1a and as described below: we soaked a 7.5-cm diameter piece of chromatography paper in 2 mL of SU-8 2010 for 30 s, spun it at 2000 rpm for 30 s, and then baked it at 95 °C for 5 min to remove the cyclopentanone in the SU-8 formula. We then exposed the photoresist and paper to 405 nm UV light (50 mW/cm2) for 10 s through a photo-mask (CAD/Art Services, Inc.) that was aligned using a mask aligner (OL-2 Mask Aligner, AB-M, Inc). After exposure, we baked the paper a second time at 95 °C for 5 min to cross-link the exposed portions of the resist. The unpolymerized photoresist was removed by soaking the paper in propylene glycol monomethyl ether acetate (PGMEA) (5 min), and by washing the pattern with propan-2-ol (3 × 10 mL). The paper was more hydrophobic after it was patterned, presumably due to residual resist bound to the paper, so we exposed the entire surface to an oxygen plasma for 10 s at 600 millitorr (SPI Plasma-Prep II, Structure Probe, Inc) to increase the hydrophilicity of the paper (Figures 2a and 2b). Figure 1 Chromatography paper patterned with photoresist. The darker lines are cured photoresist; the lighter areas are unexposed paper. (a) Patterned paper after absorbing 5 μL of Waterman red ink by capillary action. The central channel absorbs the sample ... Figure 2 Assays contaminated with (a) dirt, (b) plant pollen, and (c) graphite powder. The pictures were taken before and after running an artificial urine solution that contained 550 mM glucose and 75 μM BSA. The particulates do not move up the channels ... The patterned paper can be derivatized for biological assays by adding appropriate reagents to the test areas (Figures 1b and ​and2b).2b). In this communication, we demonstrate the method by detecting glucose and protein,[8] but the surface should be suitable for measuring many other analytes as well.[7] The glucose assay is based on the enzymatic oxidation of iodide to iodine,[9] where a color change from clear to brown is associated with the presence of glucose.[10] The protein assay is based on the color change of tetrabromophenol blue (TBPB) when it ionizes and binds to proteins;[11] a positive result in this case is indicated by a color change from yellow to blue. For the glucose assay, we spotted 0.3 μL of a 0.6 M solution of potassium iodide, followed by 0.3 μL of a 1:5 horseradish peroxidase/glucose oxidase solution (15 units of protein per mL of solution). For the protein assay, we spotted 0.3 μL of a 250-mM citrate buffer (pH 1.8) in a well separate from the glucose assay, and then layered 0.3 μL of a 3.3 mM solution of tetrabromophenol blue (TBPB) in 95% ethanol over the citrate buffer. The spotted reagents were allowed to air dry at room temperature. This pre-loaded paper gave consistent results for the protein assay regardless of storage temperature and time (when stored for 15 d both at 0 °C and at 23 °C, wrapped in aluminum foil). The glucose assay was sensitive to storage conditions, and showed decreased signal for assays run 24 h after spotting the reagents (when stored at 23 °C); when stored at 0 °C, however, the glucose assay was as sensitive after day 15 as it was on day 1. We measured artificial samples of glucose and protein in clinically relevant ranges (2.5-50 mM for glucose and 0.38-7.5 μM for bovine serum albumin (BSA))[12, 13] by dipping the bottom of each test strip in 5 μL of a pre-made test solution (Figure 2d). The fluid filled the entire pattern within ca. one minute, but the assays required 10-11 min for the paper to dry and for the color to fully develop.[14] In all cases, we observed color changes corresponding roughly in intensity to the amount of glucose and protein in the test samples, where the lowest concentrations define the lower limits to which these assays can be used (Figure 2e). For comparison, commercially-available dipsticks detect glucose at concentrations as low as 5 mM[7, 9] and protein as low as 0.75 μM;[6, 15] these limits indicate that these paper-based assays are comparable in sensitivity to commercial dipstick assays. Our assay format also allows for the measurement of multiple analytes. This paper-based assay is suitable for measuring multiple samples in parallel and in a relatively short period of time. For example, in one trial, one researcher was able to run 20 different samples (all with 550 mM glucose and 75 μM BSA) within 7.5 min (followed by another 10.5 min for the color to fully develop). An 18-min assay of this type—one capable of measuring two analytes in 20 different sample—may be efficient enough to use in high-throughput screens of larger sample pools. In the field, samples will not be measured under sterile conditions, and dust and dirt may contaminate the assays. The combination of paper and capillary action provides a mechanism for separating particulates from a biological fluid. As a demonstration, we purposely contaminated the artificial urine samples with quantities of dirt, plant pollen, and graphite powder at levels higher than we might expect to see in the samples in the field. These particulates do not move up the channels under the action of capillary wicking, and do not interfere with the assay (Figure 3). Paper strips have been used in biomedical assays for decades because they offer an inexpensive platform for colorimetric chemical testing.[1] Patterned paper has characteristics that lead to miniaturized assays that run by capillary action (e.g., without external pumping), with small volumes of fluids. These methods suggest a path for the development of simple, inexpensive, and portable diagnostic assays that may be useful in remote settings, and in particular, in less-industrialized countries where simple assays are becoming increasingly important for detecting disease and monitoring health,[16, 17], for environmental monitoring, in veterinary and agricultural practice and for other applications.

Content maybe subject to copyright    Report

Citations
More filters
Journal ArticleDOI
TL;DR: Microfluidic paper-based analytical devices are a new class of point-of-care diagnostic devices that are inexpensive, easy to use, and designed specifically for use in developing countries.
Abstract: Microfluidic paper-based analytical devices (μPADs) are a new class of point-of-care diagnostic devices that are inexpensive, easy to use, and designed specifically for use in developing countries. (To listen to a podcast about this feature, please go to the Analytical Chemistry multimedia page at pubs.acs.org/page/ancham/audio/index.html.)

2,373 citations

Journal ArticleDOI
TL;DR: This review includes challenges to scaling up, commercialisation and regulatory issues, and the factors which limit paper-based microfluidic devices to become real world products and future directions are also identified.
Abstract: Dipstick and lateral-flow formats have dominated rapid diagnostics over the last three decades. These formats gained popularity in the consumer markets due to their compactness, portability and facile interpretation without external instrumentation. However, lack of quantitation in measurements has challenged the demand of existing assay formats in consumer markets. Recently, paper-based microfluidics has emerged as a multiplexable point-of-care platform which might transcend the capabilities of existing assays in resource-limited settings. However, paper-based microfluidics can enable fluid handling and quantitative analysis for potential applications in healthcare, veterinary medicine, environmental monitoring and food safety. Currently, in its early development stages, paper-based microfluidics is considered a low-cost, lightweight, and disposable technology. The aim of this review is to discuss: (1) fabrication of paper-based microfluidic devices, (2) functionalisation of microfluidic components to increase the capabilities and the performance, (3) introduction of existing detection techniques to the paper platform and (4) exploration of extracting quantitative readouts via handheld devices and camera phones. Additionally, this review includes challenges to scaling up, commercialisation and regulatory issues. The factors which limit paper-based microfluidic devices to become real world products and future directions are also identified.

1,658 citations

Journal ArticleDOI
TL;DR: A detailed study on wax printing, a simple and inexpensive method for fabricating microfluidic devices in paper using a commercially available printer and hot plate, which creates complete hydrophobic barriers in paper that define hydrophilic channels, fluid reservoirs, and reaction zones.
Abstract: This technical note describes a detailed study on wax printing, a simple and inexpensive method for fabricating microfluidic devices in paper using a commercially available printer and hot plate. The printer prints patterns of solid wax on the surface of the paper, and the hot plate melts the wax so that it penetrates the full thickness of the paper. This process creates complete hydrophobic barriers in paper that define hydrophilic channels, fluid reservoirs, and reaction zones. The design of each device was based on a simple equation that accounts for the spreading of molten wax in paper.

1,403 citations

Journal ArticleDOI
TL;DR: A prototype system for quantifying bioassays and for exchanging the results of the assays digitally with physicians located off-site offers new opportunities for inexpensive monitoring of health, especially in situations that require physicians to travel to patients to obtain diagnostic information that might be obtained more effectively by less valuable personnel.
Abstract: This article describes a prototype system for quantifying bioassays and for exchanging the results of the assays digitally with physicians located off-site. The system uses paper-based microfluidic devices for running multiple assays simultaneously, camera phones or portable scanners for digitizing the intensity of color associated with each colorimetric assay, and established communications infrastructure for transferring the digital information from the assay site to an off-site laboratory for analysis by a trained medical professional; the diagnosis then can be returned directly to the healthcare provider in the field. The microfluidic devices were fabricated in paper using photolithography and were functionalized with reagents for colorimetric assays. The results of the assays were quantified by comparing the intensities of the color developed in each assay with those of calibration curves. An example of this system quantified clinically relevant concentrations of glucose and protein in artificial uri...

1,393 citations

Journal ArticleDOI
TL;DR: A method for fabricating 3D microfluidic devices by stacking layers of patterned paper and double-sided adhesive tape to carry out a range of new analytical protocols simply and inexpensively without external pumps is described.
Abstract: This article describes a method for fabricating 3D microfluidic devices by stacking layers of patterned paper and double-sided adhesive tape. Paper-based 3D microfluidic devices have capabilities in microfluidics that are difficult to achieve using conventional open-channel microsystems made from glass or polymers. In particular, 3D paper-based devices wick fluids and distribute microliter volumes of samples from single inlet points into arrays of detection zones (with numbers up to thousands). This capability makes it possible to carry out a range of new analytical protocols simply and inexpensively (all on a piece of paper) without external pumps. We demonstrate a prototype 3D device that tests 4 different samples for up to 4 different analytes and displays the results of the assays in a side-by-side configuration for easy comparison. Three-dimensional paper-based microfluidic devices are especially appropriate for use in distributed healthcare in the developing world and in environmental monitoring and water analysis.

1,204 citations


Cites background or methods from "Patterned Paper as a Platform for I..."

  • ...The hydrophobic polymer patterned into the paper demarcated the channels through which the fluids moved laterally (8, 9), the layers of water-impermeable doublesided tape separated channels in neighboring layers of paper, and holes cut into the tape allowed fluids to flow vertically....

    [...]

  • ...ITW Technicloth (TX 609) was patterned with SU-8 2010 photoresist (1, 8, 9)....

    [...]

  • ...Paper was impregnated with photoresist, dried, exposed to UV light through a transparency mask, and developed with acetone and isopropyl alcohol (8, 9)....

    [...]

  • ...This articles describes a new class of analytical devices fabricated by layering paper patterned into hydrophilic channels and hydrophobic walls (1, 8, 9) and tape patterned with holes that connect channels in different layers of paper....

    [...]

References
More filters
Journal ArticleDOI
TL;DR: It is concluded that microalbuminuria in patients with Type II diabetes is predictive of clinical proteinuria and increased mortality.
Abstract: We studied whether microalbuminuria (30 to 140 micrograms of albumin per milliliter) would predict the later development of increased proteinuria and early mortality in Type II diabetics. During 1973, morning urine specimens of diabetic clinic patients 50 to 75 years of age whose disease had been diagnosed the age of 45 were examined for albumin level by radioimmunoassay. Seventy-six patients with albumin concentrations of 30 to 140 micrograms per milliliter were identified for long-term follow-up. They were compared with normal controls, diabetic patients with lower albumin concentrations (75 patients with concentrations less than 15 micrograms per milliliter and 53 with concentrations of 16 to 29 micrograms per milliliter), and 28 diabetic patients with higher concentrations (greater than 140). Age, duration of diabetes, treatment method, fasting blood glucose level, blood pressure, height, and weight were determined for the four diabetic groups. After nine years the group with albumin concentrations of 30 to 140 micrograms per milliliter was more likely to have clinically detectable proteinuria (greater than 400 micrograms per milliliter) than were the groups with lower concentrations. Mortality was 148 per cent higher in this group than in normal controls--comparable to the increase (116 per cent) in the group with heavy proteinuria (albumin levels greater than 140 micrograms per milliliter). In addition, mortality was increased 76 per cent in the group with albumin levels of 16 to 29 micrograms per milliliter and 37 per cent in the group with levels below 15. We conclude that microalbuminuria in patients with Type II diabetes is predictive of clinical proteinuria and increased mortality.

1,943 citations

Journal ArticleDOI
27 Jul 2006-Nature
TL;DR: The developing world does not have access to many of the best medical diagnostic technologies; they were designed for air-conditioned laboratories, refrigerated storage of chemicals, constant supply of calibrators and reagents, stable electrical power, highly trained personnel and rapid transportation of samples.
Abstract: The developing world does not have access to many of the best medical diagnostic technologies; they were designed for air-conditioned laboratories, refrigerated storage of chemicals, a constant supply of calibrators and reagents, stable electrical power, highly trained personnel and rapid transportation of samples. Microfluidic systems allow miniaturization and integration of complex functions, which could move sophisticated diagnostic tools out of the developed-world laboratory. These systems must be inexpensive, but also accurate, reliable, rugged and well suited to the medical and social contexts of the developing world.

1,920 citations

Journal ArticleDOI
TL;DR: Although 'diseases of affluence' are increasing in developing countries, infectious diseases still impose the greatest health burden and simple, accurate and stable diagnostic tests are essential to combat these diseases.
Abstract: Although 'diseases of affluence', such as diabetes and cardiovascular disease, are increasing in developing countries, infectious diseases still impose the greatest health burden. Annually, just under 1 million people die from malaria, 4.3 million from acute respiratory infections, 2.9 million from enteric infections and 5 million from AIDS and tuberculosis. Other sexually transmitted infections and tropical parasitic infections are responsible for hundreds of thousands of deaths and an enormous burden of morbidity. More than 95% of these deaths occur in developing countries. Simple, accurate and stable diagnostic tests are essential to combat these diseases, but are usually unavailable or inaccessible to those who need them.

860 citations

Journal ArticleDOI
TL;DR: The medium AUM solidified with agar enabled the recovery of a wide range of urease‐positive and ‐negative urinary pathogens and was capable of forming crystals and encrustations resembling those found in natural urinary tract infections.
Abstract: A simple artificial urine medium (AUM) has been developed which provides conditions similar to that found in human urine. AUM solidified with agar enabled the recovery of a wide range of urease-positive and -negative urinary pathogens. Liquid AUM supported growth at concentrations of up to 10(8) cfu ml-1, as found in normal urine. Reproducible, steady-state growth also occurred over many generations in continuous culture. AUM was capable of forming crystals and encrustations resembling those found in natural urinary tract infections. The medium is a suitable replacement for normal urine for use in a wide range of experiments modelling the growth and attachment of urinary pathogens in the clinical environment.

423 citations

Journal ArticleDOI
TL;DR: An international group of eminent scientists with expertise in global health issues was asked to identify the top ten biotechnologies for improving health in developing countries, and the results offer concrete guidance to those in a position to influence the direction of research and development.
Abstract: Most research into genomics and other related biotechnologies is concerned with the priorities of industrialized nations, and yet a limited number of projects have shown that these technologies could help improve health in developing countries. To encourage the successful application of biotechnology to global health, we carried out a study in which we asked an international group of eminent scientists with expertise in global health issues to identify the top ten biotechnologies for improving health in developing countries. The results offer concrete guidance to those in a position to influence the direction of research and development, and challenge common assumptions about the relevance and affordability of biotechnology for developing countries.

371 citations