scispace - formally typeset
Search or ask a question
Journal ArticleDOI

Permalloy multilayers to reduce the effects of uniaxial anisotropy

01 Sep 1989-IEEE Transactions on Magnetics (IEEE)-Vol. 25, Iss: 5, pp 4278-4282
TL;DR: In this paper, the Stoner-Wohlfarth single-domain model is used to describe the systematic error of an angle detector using multilayers with different orientations of their anisotropy axes.
Abstract: The anisotropic magnetoresistance effect of Permalloy (Ni/sub 0.82/Fe/sub 0.18/) is used in a contactless angle detector. The uniaxial magnetic anisotropy in a Permalloy thin film causes a difference between the direction of magnetization and the magnetic field direction. This leads to a systematic error in the angle detector output. The effects of uniaxial magnetic anisotropy can be reduced by using Permalloy multilayers with different orientations of their anisotropy axes. A double layer with mutually perpendicular anisotropy axes is found to be sufficient for application in an angle detector. The Stoner-Wohlfarth single-domain model is used to describe the systematic error of an angle detector using multilayers. >

Summary (2 min read)

INTRODUCTION

  • N OUR research group a contactless angle detector I based on the anisotropic magnetoresistance effect (AMR effect) in a Permalloy thin film has been proposed [ 11.
  • The output signal of the angle detector yields the direction of magnetization (output angle 8 ) while the object is to measure the angular position of the magnet (input angle cp).
  • This systematic error is determined by the strength and direction of both the uniaxial anisotropy (UA) and the magnetic field E (Fig. 2 ).
  • The orientation of the anisotropy axis or easy axis (EA) and the strength of the UA are characterized by the angle a!.
  • Annealing is one well-known means to reduce the UA [2], [3] and in their case a 1.5 h/500"C annealing treatment proved to be sufficient to meet the requirements, viz.

MULTILAYERS

  • This is obvious from the fact that a single layer with two mutually perpendicular easy axes with equal anisotropy constants K , is magnetically isotropic.
  • A ferromagnetic exchange interaction between the layers would try to align their magnetization and would cause an additional decrease of the systematic error.
  • They indicate the success of the technological realization.
  • This is, of course, an approximation of the actual anisotropy field strengths Hk,i of the different layers.
  • The value of the ani_sotropy field strength calculated this way will be called Hk.

TECHNOLOGY

  • Therefore, the Cr layer hardly influences, that is, short-circuits, the AMR effect in the Permalloy layers (thickness 25 or 50 nm) and does not disturb the AMR signal of the angle detector.
  • The actual advantage is negligible, because the maximum angle between the magnetization directions in neighboring films is small for the field strengths used in the angle detector.
  • The domain wall between subsequent Permalloy layers, having a width of a few nanometers, is restricted to the intermediate layer, so the exchange interaction has no influence on the magnetization orientation in the Permalloy layers.
  • In practice, three technological problems remain: Thickness variations within one layer up to 10 percent occur in their sputtering system due to the inhomogeneous sputter process, causing thickness differences between the layers of a multilayer film.

CHARACTERIZATION

  • If the IHM measures the easy-axis curve of layer 1 (EAl), it also measures the hard-axis curve of layer 2 (HA2), because EA1 coincides with HA2 in a double-layer.
  • A fourlayer cannot be characterized with the IHM.
  • The Crowther method [8] is normally used to measure the angular dispersion in the easy-axis orientation.

RESULTS AND DISCUSSION I 4281

  • The authors sputtered several double-layer films, with different Cr thickness tcr, and one four-layer film.
  • The maximum deviation of the easy-axis orientation with regard to the ideal orientation is found to be 7".
  • To explain the observed effects, this coupling should tend to increase the angle between the magnetization in two neighboring layers.
  • Therefore, the existence of an antiferromagnetic exchange coupling between the Permalloy layers is regarded as a candidate for the observed deviations.
  • Further experiments will be necessary to provide an insight into this problem.

CONCLUSIONS

  • The effect of the uniaxial anisotropy on the performance of the angle detector can be reduced by using multilayers of Permalloy with different easy-axis orientation.
  • The anisotropy field strength Chromium proved to be successful and has the advantage of not disturbing the AMR signal of the angle detector.
  • The model predicts an even better performance of four-layers but they require a more accu-rate technology.
  • As a consequence, calculations based on the model yield an average anisotropy field strength.
  • This is probably due to the neglect of magnetic coupling between the layers.

Did you find this useful? Give us your feedback

Content maybe subject to copyright    Report

4278
IEEE TRANSACTIONS ON MAGNETICS,
VOL.
25.
NO.
5.
SEPTEMBER
1989
Permalloy Multilayers to Reduce the Effects
of
Uniaxial Anisotropy
JOHAN W. WIEBERDINK
AND
KEES
J.
M. EIJKEL
Abstract-The anisotropic magnetoresistance effect of Permalloy
(Ni0.82Fe0.,8) is used in a contactless angle detector
[l].
The uniaxial
magnetic anisotropy in a Permalloy thin film causes a difference be-
tween the magnetization and the magnetic field direction. This leads to
a systematic error in the angle detector output. The effects
of
uniaxial
magnetic anisotropy can be reduced by using Permalloy multilayers
with different orientation
of
their anisotropy axes.
A
double layer with
mutually perpendicular anisotropy axes is found to be sufficient for
application in an angle detector. The Stoner-Wohlfarth single-domain
model is used to describe the systematic error of an angle detector using
multilayers.
INTRODUCTION
N OUR research group a contactless angle detector
I
based on the anisotropic magnetoresistance effect (AMR
effect) in a Permalloy thin film has been proposed
[
11.
The
AMR effect is used to detect the direction of magnetiza-
tion
E
in the Permalloy film which is influenced by the
magnetic field of a rotatable permanent magnet. The
output signal of the angle detector yields the direction of
magnetization (output angle
8
)
while the object is to
measure the angular position of the magnet (input angle
cp).
The uniaxial magnetic anisotropy of Permalloy causes
a difference between the angles
cp
and
8
resulting in a
systematic error
(cp
-
e)
of the angle detector (see Fig.
1).
This systematic error is determined by the strength and
direction
of
both the uniaxial anisotropy (UA) and the
magnetic field
E
(Fig.
2).
The UA
is
induced during the
deposition of a Permalloy film and can be oriented with
the aid of an external magnetic field during film growth.
The orientation of the anisotropy axis or easy axis (EA)
and the strength of the UA are characterized by the angle
a!
(Fig.
1)
and the anisotropy field strength
Hk.
It is possible to calculate the systematic error if
CY
and
the ratio
Hk/H
are known. In this way the angle detector
output can be corrected. However, it
is
preferable to elim-
inate the effects of the UA in the Permalloy film itself.
Annealing is one well-known means to reduce the UA
[2],
[3] and in our case a
1.5
h/500"C annealing treatment
proved to be sufficient to meet the requirements, viz.
(cp
-
e)
I
0.1"
for
H
=
10
kA/m. Another solution
Manuscript received December 1, 1988; revised February
2,
1989. This
The authors are with the University
of
Twente, EL-TDM, P.O.
Box
IEEE Log Number 8927698.
work was supported by the Netherlands Technology Foundation
(STW).
217, 7500 AE Enschede, The Netherlands.
Fig. 1.
A
Permalloy
film
with uniaxial anisotropy.
L
Fig. 2. The systematic
error
(p
-
e)
of the angle detector as a function
of
lp.
exploits the inhomogeneity
of
the magnetic field of the
permanent magnet to reduce the systematic error
[3].
In
this paper a new approach to reduce the effects of UA is
proposed using multilayers
of
Permalloy with different
orientation of their easy axes.
SINGLE
LAYER
We start by describing the magnetic behavior of a sin-
gle layer in order to describe the systematic error of an
angle detector using multilayers. For a Permalloy film
with UA in a homogeneous magnetic field the angle
(cp
-
e)
follows the Stoner-Wohlfarth single-domain
model [4]:
Hk
sin
(cp
-
e)
=
-sin
2(8
-
CY).
2H
One cannot solve
e(
cp)
explicitely, but (1) can be re-
written as an iteration process
(2).
Now
8
(cp)
can be cal-
culated for all values of
cp
starting with
eo
=
cp
and the
exact solution can be approximated as accurately as nec-
essary.
0018-9464/89/0900-4278$01
.OO
0
1989 IEEE

WIEBERDINK
AND
EIJKEL:
REDUCTION
OF
THE
EFFECTS
OF
UNIAXIAL
ANISOTROPY
4279
Alternatively, one can approximate
(cp
-
0)
(cp)
with the
first two terms of a simple Fourier series derived from
(1).
This Fourier series
(3)
clearly shows how
(cp
-
0)
de-
pends on
cp
and the ratio
Hk/H
and is very appropriate for
describing the systematic error of multilayers.
For a single-layer Permalloy film we have
Hk
=
450
A/m,
so
the maximum systematic error of the angle de-
tector at
H
=
10
kA/m is
1.3"
(Fig.
2).
MULTILAYERS
The effect of the UA in a Permalloy film on the perfor-
mance of the angle detector can be reduced by using mul-
tilayers of Permalloy with different easy-axis orientation.
This is obvious from the fact that a single layer with two
mutually perpendicular easy axes with equal anisotropy
constants
K,
is magnetically isotropic. The total anisot-
ropy energy
E,
of such a film is independent of
0:
Metzdorf
[5]
managed to reorient a part of the anisotropy
in the hard axis direction and realized isotropic Permalloy
films. However, the magnetic properties of these films are
not stable in a magnetic field for the desired operating
temperatures of the angle detector. In order to approxi-
mate the ideal situation we realize multilayers with dif-
ferent EA orientation.
We used a computer simulation to calculate the system-
atic error of a double- and four-layer and determine its
maximum value (Table I). Here, an ideal situation is con-
sidered: the
Hk,i
and thickness
ti
of the layers
(i
=
1,
2
or
1
-
*
4)
are equal and the angle between the EA of
subsequent layers is exactly
n/2
(double-layer) or
n/4
(four-layer). The influence of exchange and magnetostatic
interaction between the layers is neglected.
A ferromagnetic exchange interaction between the lay-
ers would try to align their magnetization and would cause
an additional decrease
of
the systematic error. An anti-
ferromagnetic exchange interaction or a magnetostatic in-
teraction would try to direct the magnetizations antipar-
allel and would increase the systematic error.
The computer simulation uses the iteration method
(2)
with the corresponding
ai
to calculate the exact magneti-
zation direction in each layer of a multilayer film. The
average magnetization direction of a film,
e(cp),
is de-
fined as the average value of
8;
over the number of layers.
The averaging mechanism that occurs in the angle detec-
tor includes the nonlinear AMR effect, but for
H
>>
Hk
both averaging mechanisms provide approximately equal
results. Table I shows the maximum values of
(cp
-
6
)
(
cp)
as
a
function of the number of layers (ver-
TABLE
I
MAXIMUM
OF
((0
-
6
)
((0)
OF
MULTILAYERS
FOR
DIFFERENT VALUES
OF
Hk/H
H,/H
=
((0
-
e),,,
Func_tion
(in degrees)
0.2
0.1 0.05
((0
-
e
~(0)
Single-layer
5.8
2.9
1.5
sin
(2~)
Double-layer
0.57 0.15
0.036
sin
(4~)
Four-layer
0.014 0.0089
0.000056
sin
(8~)
tical) and the value of
Hk/H
(horizontal). In the last col-
umn the shape of
(cp
-
e
)
as a function of
cp
is given.
From Table I it is clear that (5) approximates the system-
atic error of multilayers
(
a,
=
0):
with
C1
=
1,
C2
=
-1,
and
C4
=
2.5
(5)
with
n
being the number of layers. The same result can
be obtained by using
(3)
for the successive Permalloy lay-
ers of a film. One simply has to add the expressions for
(cp
-
ei)
(
cp)
to obtain
(cp
-
6
)
(cp).
In case of a double-
layer the sin
(2cp)
term is eliminated and in case of a four-
layer the sin
(4cp)
term is also eliminated.
In a nonideal situation the above terms are not com-
pletely eliminated due to differences in the
Hk,i,
ti,
and
a;
of the layers, caused by technological inaccuracies. In that
case,
(cp
-
0
)
(cp)
can be approximated with the first
three terms of a Fourier series
(6).
The coefficients
c,
,
c2,
and
c4
denote the strength of the corresponding Fourier
terms and depend on the ratio
Hk/H
and the technological
accuracy. The constants
6,,
a2,
and
64
represent the phase
of the Fourier terms and depend on the field direction at
cp
=
0
with respect to
a,.
The quality factors
q,,
q2,
and
q4
defined in
(6)
are independent of
Hk/H.
They indicate
the success of the technological realization. For an ideal
double-layer we find
q1
=
0,
while an ideal four-layer
yields
q1
=
q2
=
0.
(cp
-
e)(,)
=
c,
sin
(2cp
+
6,)
-
c2
sin
(4cp
+
6,)
+
c4
sin
(8cp
+
6,)
+
Hk
=
q1
-
sin
(2cp
+
6,)
2H
If
(cp
-
6
)
(cp)
is determined for a multilayer, the an-
isotropy field strength of the Permalloy can be calculated
from the Fourier coefficients in
(6).
This is, of course, an
approximation of the actual anisotropy field strengths
Hk,i
of
the different layers. The value of the ani_sotropy
field strength calculated this way will be called
Hk.
It is

4280
I
IEEE TRANSACTIONS
ON
MAGNETICS,
VOL.
25.
NO.
5,
SEPTEMBER
1989
derived from the first term in
(6)
which is completely
present
double-layer:
'fik
=
2
H
4
r-
four-layer:
fik
=
2H
4 -.
2/25
J
(7)
TECHNOLOGY
The Permalloy (82 at
%
Ni and 18 at
%
Fe) films are
RF sputtered on oxidized silicon wafers and a fixed bias
field of
2
kA/m is used during film growth to direct the
easy-axis orientation. In order to realize multilayers with
different EA in our sputtering system it is necessary to
break the vacuum and rotate the wafer by hand.
In our case, the bias field is too weak to induce a new
EA in the next layer
so
the EA of the previous layer is
continued
[6].
We used an intermediate layer of chro-
mium to interrupt the continuity of the Permalloy film
growth. Chromium is very suitable because a thin layer
of
3
nm is sufficient for magnetic separation
[7]
while the
resistivity of Cr is relatively high. Therefore, the Cr layer
hardly influences, that is, short-circuits, the AMR effect
in the Permalloy layers (thickness
25
or
50
nm) and does
not disturb the AMR signal of the angle detector.
Application of a ferromagnetic intermediate layer would
establish exchange interaction between the Permalloy lay-
ers and would further reduce
(cp
-
6
)
(cp).
However, the
actual advantage is negligible, because the maximum an-
gle between the magnetization directions in neighboring
films is small for the field strengths used in the angle de-
tector. Consequently, the domain wall between subse-
quent Permalloy layers, having a width of a few nano-
meters, is restricted to the intermediate layer,
so
the
exchange interaction has no influence on the magnetiza-
tion orientation in the Permalloy layers. In order to obtain
a symmetrical structure, extra Cr bottom and top layers
are needed (Fig.
3).
Otherwise, the values
of
Hk,[
and
coercivity
H,,
of separate Permalloy layers differ consid-
erably.
In practice, three technological problems remain: The
accuracy of the angle between the easy axes is determined
by both the inhomogeneity of the bias field and the man-
ual rotation of the wafer. Thickness variations within one
layer up to 10 percent occur in our sputtering system due
to the inhomogeneous sputter process, causing thickness
differences between the layers of a multilayer film. This
is a consequence of the small sputter target and the influ-
ence of the bias field on the plasma distribution.
CHARACTERIZATION
An Inductive Hysteresis Meter (IHM) is used to deter-
mine the
H,,;, Hk,;,
and saturation magnetic moment
312,,;
of both layers
(i
=
1, 2) of a double-layer. The layer
thickness
ti
is assumed to be proportional to
3n,,;.
The
32-H
curve of a double-layer is a superposition of the two
3n-H
curves of the separate layers.
If
the IHM measures
Cr
NiFe layer
2
Cr
NiFe
layer
1
Fig.
3.
A double-layer structure.
(b)
Fig.
4.
32-N
curve EA1
+
HA2 (a) and EA2
+
HA1 (b)
of
a double-
layer.
Fig.
5.
A sample with point contacts in pseudo-Hall configuration.
the easy-axis curve of layer 1 (EAl), it also measures the
hard-axis curve of layer
2
(HA2), because EA1 coincides
with HA2 in a double-layer. Fig. 4(a) shows the
32-H
curve EA1
+
HA2 from which
Hc,l,
3ns,1,
and
Hk,*
are
determined. After rotating the film
90°,
EA2
+
HA1,
with
H,,*,
3ns,2,
and
Hk,
I,
is measured (Fig. 4(b)). A four-
layer cannot be characterized with the IHM.
The Crowther method
[8]
is normally used to measure
the angular dispersion in the easy-axis orientation. We
used it to determine the exact angle between the different
easy axes of a multilayer.
A third characterization method measures the Permal-
loy film in a pseudo-Hall configuration (Fig.
5).
The film
with voltage and current point contacts is rotated over
0"
I
cp
I
180"
in a magnetic field
H
I
6
kA/m and
the pseudo-Hall voltage
Veh
(
cp
)
is measured
[9].
A com-
puter program calculates
8
(
cp)
and determines the Fou-
rier components of
(
cp
-
6
(
cp
).

WIEBERDINK AND EIJKEL: REDUCTION
OF
THE EFFECTS
OF
UNIAXIAL ANISOTROPY
RESULTS
AND
DISCUSSION
I
4281
We sputtered several double-layer films, with different
Cr thickness
tcr,
and one four-layer film. The sputtered
wafers were broken into samples of
1
x
1 cm'. The coer-
civity
H,
of a double-layer is reduced
(H,
=
25
A/m at
tcr
=
3
nm) and our results concerning
H,
as a function
of
tcr
agree with Herd and Ahn
[lo].
The differences be-
tween the
Hk,i
and
t,
(i
=
l,
2)
of a double-layer sample
vary up to
10
percent. The maximum deviation of the
easy-axis orientation with regard to the ideal orientation
is found to be
7".
Each wafer contains some samples with
a deviation of less than
1
O.
In general, the best samples
are positioned at the center of a wafer and the relation
between the technological success of a sample and
(cp
-
0
)
(cp)
is always very obvious. We present the re-
sults of a successful double-layer and four-layer sample.
The systematic error
(cp
-
6
)
(cp)
of a double-layer
(Fig.
6)
is a sin
(4~)
function with an amplitude approx-
imately proportional to
(&/2H)*.
For higher values
of the magnetic field strength (not shown in Fig.
6),
the
sin
(2cp)
term with amplitude
qlHk/2H
dominates in
(cp
-
0
)
(cp).
The factor
q1
indicates the suppression of
the sin
(2cp)
term and should be zero for an ideal double-
layer. The amplitude of
(cp
-
e)(cp)
is slightly higher
than expected from the model. Therefore, the
Hk
of a dou-
ble-layer, calculated using
(7),
is increased in comparison
with the
Hk,,
of the separate layers.
Hk
is found to depend
on the magnetic field strength and increases up to
600
A/m at
H
=
6
kA/m. This is not predicted by the model.
The systematic error
(cp
-
6)
(cp)
of a four-layer (Fig.
7)
is, in an ideal case, a sin
(8p)
function with an ampli-
tude proportional
to
(Hk/2H)4.
The sin
(8~)
term in the
film of Fig.
7
is only recognizable for the lowest magnetic
field strength
(500
A/m) because the sin
(2cp)
term dom-
inates for
H
I
1
kA/m. The influence of the sin
(4p)
term with amplitude
q2
(
Hk/2
H
)'
is negligible because
Hk/H
<<
1.
Good four-layers
(qI
=
q2
=
0.01)
can
achieve
(cp
-
8)(p)
I
0.05"
forH
=
5
kA/m.
Again, the behavior of the film deviates from the model:
The
Hk
of the four-layer, calculated using
(7),
depends
strongly on the magnetic field strength and varies from
350
A/m at
H
=
500
A/m to
1
kA/m at
H
=
6
kA/m.
The unexpected dependence oft& on
H
does not occur
in single-layer films. Therefore, the observed deviation
from the model is ascribed to the existence of magnetic
coupling between the layers, which is neglected in the
model. To explain the observed effects, this coupling
should tend to increase the angle between the magneti-
zation in two neighboring layers. Such a coupling can be
either magnetostatic, viz. dipolar coupling via planar de-
magnetization, or of an exchange type. Computer simu-
lations show that the demagnetizing field of our films is
orders of magnitude too small to account for the observed
behavior. Therefore, the existence of an antiferromag-
netic exchange coupling between the Permalloy layers is
regarded as a candidate for the observed deviations. Such
an interaction between Fe thin films across a Cr interme-
diate layer has recently been reported by Griinberg
[l
11.
T
4-
E
3-
Fig.
6.
Measured
(q
-
6
)
(q)
of a double-layer.
(
fCr
=
3
nm,
t,,,,
=
50
nm,
Hk,,
=
400
A/m,
q,
=
0.02.)
Fig.
7.
Measured
(q
-
6
)(q)
of a fourdayer.
(tCr
=
3
nm,
tNIFe
=
25
nm,
q,
=
0.1,
q2
=
0.1.)
His experiments concern epitaxially grown Fe and Cr lay-
ers, which seems to be of crucial importance for the ob-
served pronounced antiferromagnetic coupling between
the Fe layers. The question whether a weak antiferro-
magnetic exchange coupling between polycrystalline
Permalloy layers across a thin polycrystalline Cr inter-
mediate layer is the cause of the observed dependence of
fik
on
H
is
a very interesting one. Further experiments
will be necessary to provide an insight into this problem.
CONCLUSIONS
The effect of the uniaxial anisotropy on the perfor-
mance of the angle detector can be reduced by using mul-
tilayers of Permalloy with different easy-axis orientation.
The anisotropy field strength
Hk
and the thickness of each
layer must be equal and the angle between their easy axes
must be exactly
7r/2
(double-layer) or
7r/4
(four-layer).
In this ideal situation, the systematic error
(cp
-
6
)(cp)
of the angle detector is in good approximation propor-
tional to
(Hk/2H)"
sin
(2ncp),
where
n
is the number of
layers
(n
=
2,
4).
In order to induce a new easy-axis orientation during
deposition of a Permalloy layer on top of another Perm-
alloy layer in a weak bias field, an intermediate layer is
necessary to interrupt the continuity of the Permalloy, be-
cause otherwise the easy-axis orientation of the previous
layer is continued. Chromium proved to be successful and
has the advantage of not disturbing the
AMR
signal of the
angle detector.
We realized double-layers that meet the requirements
for application in an angle detector:
(
cp
-
8
)
(cp)
<
0.1
"
for
H
=
10
kA/m. The model predicts an even better
performance of four-layers but they require a more accu-

4282
IEEE TRANSACTIONS
ON
MAGNETICS,
VOL.
25.
NO.
5.
SEPTEMBER
1989
rate technology. Our laboratory conditions are insufficient
to realize good four-layers. The amplitude of
(
p
-
8
)
(
p)
of double- and four-layers is higher than predicted by the
model. As a consequence, calculations based on the model
yield an average anisotropy field strength
Hk
of a multi-
layer that is higher than the
Hk,i
of
the separate layers.
This is probably due to the neglect
of
magnetic coupling
between the layers. Antiferromagnetic exchange coupling
between the Permalloy and chromium layers is a possible
candidate
for
such a coupling. Further experiments have
to be performed to solve this question.
ACKNOWLEDGMENT
This work is part
of
the research on Permalloy sensors
in the Transducers and Materials Science group of the
Faculty of Electrical Engineering, University of Twente,
under the supervision
of
prof. dr. Th.
J.
A.
Popma and
prof, dr.
J.
H.
J.
Fluitman. The authors would like to
thank ir.
P.
de Haan and dr. R. M. de Ridder for helpful
discussions.
REFERENCES
K.
J.
Eijkel and
J.
H.
J.
Fluitman, “Angle detection based
on
the
resistance anisotropy of permalloy,”
IEEE
Trans. Magn.,
vol. MAG-
J.
W.
Wieberdink, M. Sc. thesis, University of Twente, UT/EL/TDM
070.2386, 1988
(in Dutch).
K.
J.
Eijkel and R. Rijk, “Contactless angle detection using permal-
loy,”
IEEE
Trans. Magn.,
vol.
24,
pp.
1761-1763, 1988.
22,
pp.
955-957, 1986.
[4]
M. Prutton,
Thin Ferromagnetic Films.
London, UK: Butterworth,
1964,
p.
55.
[SI
W. Metzdorf, “Die Beeinflussbarkeit der uniaxialen Anisotropie auf-
gedampfter Permalloyschichten durch Tempern im Magnetfeld,”
Zeirschrij2
Ang.
Phys.,
vol.
18,
pp.
534-540, 1965
(in German).
[6]
K.
J.
Eijkel,
“A
thin film magnetoresistive angle detector,” Ph.D.
dissertation, University of Twente,
1988.
171
P. Swiatek, F. Saurenbach, Y. Pang, P. Griinberg, and
W.
Zinn,
“Exchange coupling of ferromagnetic films across nonmagnetic in-
terlayers,”
.I.
Appl.
Phys.,
vol.
61,
pp.
3753-3755, 1987.
[8]
T.
S.
Crowther, “Angular and magnitude dispersion of the anisotropy
in magnetic films,”
J.
Appl.
Phys.,
vol.
18,
pp.
580-586, 1963.
[9]
K.
J.
Eijkel, “Measurement of the anisotropy in permalloy,”
IEEE
Trans. Magn.,
vol.
24,
pp.
1957-1959, 1988.
[lo]
S.
R. Herd and K. Y. Ahn, “Magnetic domain structures in multi-
layered NiFe films,”
J.
Appl.
Phys.,
vol.
50,
pp.
2384-2386, 1979.
[I
11
P. Griinberg, in R. F.
C.
Fallow
et
al., Thin Film Growrh Techniques
for
Low
Dimensional
Siructures
(NATO AS1 Series,
Series
B
Physics
Vol.
163).
New York,
NY:
Plenum,
1987,
pp.
487-505.
Johan
W. Wieberdink
was born in Apeldoorn, The Netherlands, in
1963.
He
received the M.Sc. degree in electrical engineering
from
the University
of Twente, Enschede, The Netherlands, in
1988.
Kees
J.
M.
Eijkel
was born
in
Heiloo, The Netherlands, in
1959.
He
re-
ceived the M.Sc. degree in mathematics from the University of Amster-
dam, Amsterdam, The Netherlands, in
1983
and the Ph.D. degree from the
University of Twente, Enschede, The Netherlands, in
1988.
Citations
More filters
Journal ArticleDOI
TL;DR: In this article, an introduction to the theory of the anisotropic magnetoresistance effect in ferromagnetic thin films is given, ending in a treatment of the minimalization of the free energy which is the result of the intrinsic and extrinsic anisotropies of the thin-film structure.
Abstract: An introduction to the theory of the anisotropic magnetoresistance effect in ferromagnetic thin films is given, ending in a treatment of the minimalization of the free energy which is the result of the intrinsic and extrinsic anisotropies of the thin-film structure. The anisotropic magnetoresistance effect in long strips is reviewed. Attention is given to problems like the formation of domains and measures like biasing and linearization. The paper concludes with a description of some applications which are being developed by the authors: (1) an analyser for the stray field of recording heads; (2) a sensitive magnetometer; (3) an accurate absolute angle detector; and (4) an absolute (linear) position detector.

23 citations

Journal ArticleDOI
01 May 1965-Nature
TL;DR: Prutton as mentioned in this paper described thin ferromagnetic films as a "thin Ferromagnetic film" and showed how to make them work well in the real world. Pp. viii + 269.
Abstract: Thin Ferromagnetic Films By M. Prutton. Pp. viii + 269. (London: Butterworth and Co. (Publishers), Ltd., 1964.) 80s.

15 citations

Journal ArticleDOI
TL;DR: In this paper, the AMR effect of single-domain film-resistors is used for magnetic field and linear/angular displacement sensing, and a pseudo-super-paramagnetic behavior is observed.
Abstract: The AMR effect of single-domain film-resistors is being widely used for magnetic field and linear/angular displacement sensing. However, several constrains attributed to the repeatability of magnetization orientation limit the accuracy of such devices. There is a trade-off between device sensitivity and measurement repeatability; the anisotropy field HK affects both parameters in an inverse manner. To overcome such problems we propose the employment of AMR film-resistors as fluxgate devices. Using a rotating magnetic field vector as excitation, the anisotropic magnetoresistance material is kept continuously in saturation and a pseudo-super-paramagnetic behaviour is observed. Thus, the signal noise coming from Barkhausen jumps can be narrowed down to zero.

12 citations

Journal ArticleDOI
TL;DR: In this article, the effect of variation in the thickness of ion assisted ion beam sputtered MgO spacer layer deposited at oxygen ion assisted energy of 50 eV on the extent of magnetic coupling of NiFe and CoFe layers in Si/NiFe(10 nm)/Mg(1.5
Abstract: The effect of variation in the thickness of ion assisted ion beam sputtered MgO spacer layer deposited at oxygen ion assisted energy of 50 eV on the extent of magnetic coupling of NiFe and CoFe layers in Si/NiFe(10 nm)/Mg(1 nm)/MgO(2,4,6 nm)/CoFe(10 nm) sandwich structure is investigated. At MgO spacer layer thickness of 4 nm, the separate reversal of magnetizations of the two ferromagnetic layers is observed in the hystresis loop recorded along easy direction. This results in a 3.5 Oe wide plateau like region during magnetization reversal, which became 4.5 Oe at 6 nm thin MgO. At 2 nm thin MgO, the absence of plateau during magnetization reversal region revealed ferromagnetic coupling between the two ferromagnetic layers, which is understood to arise due to the growth of very thin and low density (1.22 gm/cc) MgO spacer layer, indicating the presence of pinholes as revealed by x-ray reflectometry. After vaccum annealing (200 °C/1 h), the plateau region for 4 and 6 nm thin MgO case decreased to 1.5 Oe and...

11 citations

Journal ArticleDOI
TL;DR: In this article, the magnetic properties of sputtered permalloy (Ni80Fe20) multilayers grown changing the anisotropy direction 90° in successive layers were reported.
Abstract: This work reports the magnetic properties of sputtered permalloy (Ni80Fe20) multilayers grown changing the anisotropy direction 90° in successive layers. Magnetic measurements show how the saturating field can be controlled by the thickness ratio between different anisotropy layers and how the coercive field is reduced increasing the number of layers. The linearity of the hysteresis loop is also improved when increasing the number of layers. Magnetic measurements are compared to simulations based on a Stoner-Wolfarth magnetization rotation mechanism.

9 citations

References
More filters
Journal ArticleDOI
TL;DR: In this article, a contactless angle detector based on the anisotropic magnetoresistance effect (AMR effect) in a permalloy thin film is presented, and the results of high-temperature annealing treatment of the pemalloy film are discussed.
Abstract: An overview is given of the results of our research on a contactless angle detector based on the anisotropic magnetoresistance effect (AMR effect) in a permalloy thin film. The results of high-temperature annealing treatment of the pemalloy film are discussed. Such a treatment suppresses the effects of the uniaxial magnetic anisotropy that is present in a permalloy thin film and increases the AMR effect, thus improving the detector signal. The performance of the detector throughout a temperature range of 20 to 120 °C and the results of heat treatment at 125 °C for 1 week have been tested.

14 citations


"Permalloy multilayers to reduce the..." refers background in this paper

  • ...In our case, the bias field is too weak to induce a new EA in the next layer so the EA of the previous layer is continued [6]....

    [...]

Journal ArticleDOI
TL;DR: In this article, a new type of angle detector is described, which consists of a ferromagnetic film opposite to a rotatable permanent magnet and the magnetic anisotropy of the film material and the unbalance of the elements used in the detector.
Abstract: A newly developed type of angle detector is described. The device consists of a ferromagnetic film opposite to a rotatable permanent magnet. When choosing a film with magnetization-dependent resistance anisotropy, the direction of the in-plane field of the permanent magnet can be measured electronically. Theory and experiment prove that detectors with an accuracy of the order of 0.1 degree can be produced. A model based on the resistance anisotropy effect and the Stoner-Wohlfarth model for single domains explains the behaviour of the device accurately. Two phenomena are responsible for eventual errors in the detector output: the magnetic anisotropy of the film material and the unbalance of the elements used in the detector. Both of them are described by the model with high accuracy. Methods have been developed to reduce their influence to a minimum. The detector output is synchro-resolver compatible.

9 citations

Journal ArticleDOI
TL;DR: In this article, a measurement system is described, which accurately determines the anisotropy field H/sub k/ and the orientation of the easy-axis in a permalloy film or in any material showing magnetization induced resistance anisotropic.
Abstract: A measurement system is described, which accurately determines the anisotropy field H/sub k/ and the orientation of the easy-axis in a permalloy film or in any material showing magnetization induced resistance anisotropy. An accuracy of 0.1% in H/sub k/ and 0.1 degrees in easy-axis orientation is reached in permalloy when the applied field strength is 2.5 H/sub k/. Deviations from the Stoner-Wohlfarth single domain model can be recognized after the analysis of the measurement. Four electrical contacts have to be positioned on the permalloy in a planar-Hall configuration. Aluminum contacts realized by a standard lithographic process are used, providing a reference for the easy-axis orientation and an accurate relative orientation of the different planar-Hall elements that can be made out of a single film. >

6 citations

Journal ArticleDOI
TL;DR: In this paper, an overview of measurements on angle detectors is given, and three modifications of the original concept of the planar-Hall elements are treated: a ring-shaped element having increased output voltage, an optimized configuration of a pair of planar Hall elements and a permanent magnet, to cancel out the effects of magnetic anisotropy in the permalloy on the accuracy of the angle detector, and an annealing step at 500 degrees C applied to the permaloy to create a magnetically isotropic film.
Abstract: An overview is given of measurements on angle detectors. The detectors consist of a pair of planar-Hall elements opposite to a rotatable magnet. The measurements are performed on a number of planar-Hall elements of different shape and size, and show good agreement with a previously described theoretical mode. To increase the accuracy of the angle detector, three modifications of the original concept of the planar-Hall elements are treated: a ring-shaped element having increased output voltage; an optimized configuration of a pair of planar-Hall elements and a permanent magnet, to cancel out the effects of magnetic anisotropy in the permalloy on the accuracy of the angle detector; and an annealing step at 500 degrees C applied to the permalloy to create a magnetically isotropic film. The results of measurements on planar-Hall elements as suggested in modifications are presented and show good agreement with theory. >

4 citations

Book ChapterDOI
01 Jan 1987
TL;DR: In this article, the authors used the magnetooptic Kerr effect (MOKE) and lightscattering (LS) from spinwaves to measure the properties of thin magnetic films and multilayered structures.
Abstract: Magnetooptic Kerr effect (MOKE) as well as lightscattering (LS) from spinwaves have now emerged as powerfull tools to measure some properties of thin magnetic films and multilayered structures. MOKE responds to the static-, LS to the dynamic part of the magnetization. The magnetic properties in turn can be changed due to effects caused by the layering. The aim of this article is to show how MOKE and LS can be used to explore the nature and size of dipolar and exchange coupling of ferromagnetic films across nonmagnetic or antiferromagnetic intermediate films. The interlayer exchange can be ferro- or antiferromagnetic, resulting in unique differences in the static- and dynamic magnetic properties of such structures.

2 citations