scispace - formally typeset
Search or ask a question
Journal ArticleDOI

Point-of-Care Ultrasonography

23 Feb 2011-The New England Journal of Medicine (Massachusetts Medical Society)-Vol. 364, Iss: 8, pp 749-757
TL;DR: This review includes videos demonstrating the use of ultrasonography to guide central venous access, detect pneumothorax, detect evidence of hemorrhage after trauma, and screen for abdominal aortic aneurysm.
Abstract: Compact ultrasound technology has facilitated growth in point-of-care uses in many specialties. This review includes videos demonstrating the use of ultrasonography to guide central venous access, detect pneumothorax, detect evidence of hemorrhage after trauma, and screen for abdominal aortic aneurysm.

Content maybe subject to copyright    Report

Citations
More filters
Journal ArticleDOI
TL;DR: For the first time, evidence-based clinical recommendations comprehensively address this branch of point-of-care ultrasound, providing a framework for FoCUS to standardize its application in different clinical settings around the world.
Abstract: Background Focused cardiac ultrasound (FoCUS) is a simplified, clinician-performed application of echocardiography that is rapidly expanding in use, especially in emergency and critical care medicine. Performed by appropriately trained clinicians, typically not cardiologists, FoCUS ascertains the essential information needed in critical scenarios for time-sensitive clinical decision making. A need exists for quality evidence-based review and clinical recommendations on its use. Methods The World Interactive Network Focused on Critical UltraSound conducted an international, multispecialty, evidence-based, methodologically rigorous consensus process on FoCUS. Thirty-three experts from 16 countries were involved. A systematic multiple-database, double-track literature search (January 1980 to September 2013) was performed. The Grading of Recommendation, Assessment, Development and Evaluation method was used to determine the quality of available evidence and subsequent development of the recommendations. Evidence-based panel judgment and consensus was collected and analyzed by means of the RAND appropriateness method. Results During four conferences (in New Delhi, Milan, Boston, and Barcelona), 108 statements were elaborated and discussed. Face-to-face debates were held in two rounds using the modified Delphi technique. Disagreement occurred for 10 statements. Weak or conditional recommendations were made for two statements and strong or very strong recommendations for 96. These recommendations delineate the nature, applications, technique, potential benefits, clinical integration, education, and certification principles for FoCUS, both for adults and pediatric patients. Conclusions This document presents the results of the first International Conference on FoCUS. For the first time, evidence-based clinical recommendations comprehensively address this branch of point-of-care ultrasound, providing a framework for FoCUS to standardize its application in different clinical settings around the world.

397 citations


Cites background from "Point-of-Care Ultrasonography"

  • ...This statement was meant to define the overall scope of FoCUS and to highlight the principles of FoCUS practice common to all point-of-care ultrasound applications.(58,59,98) The panel identified as primary goals of FoCUS the understanding of patients’ cardiovascular physiology and pathophysiology and the ‘‘reduction of diagnostic uncertainty....

    [...]

Journal ArticleDOI
TL;DR: This paper presents a meta-modelling framework for estimating the modeled response of the immune system to various types of injury and shows clear patterns of decline in response to certain types of injuries.
Abstract: Samiksha Nayak,†,§ Nicole R. Blumenfeld,†,§ Tassaneewan Laksanasopin,‡ and Samuel K. Sia*,† †Department of Biomedical Engineering, Columbia University, 351 Engineering Terrace, 1210 Amsterdam Avenue, New York, New York 10027, United States ‡Biological Engineering Program, Faculty of Engineering, King Mongkut’s University of Technology Thonburi, 126 Pracha Uthit Road, Bang Mod, Thung Khru, Bangkok 10140, Thailand

369 citations

OtherDOI
TL;DR: This article provides a comprehensive review of dehydration assessment and presents a unique evaluation of the dehydration and performance literature, suggesting a ≥ 2% dehydration threshold for impaired endurance exercise performance mediated by volume loss.
Abstract: This article provides a comprehensive review of dehydration assessment and presents a unique evaluation of the dehydration and performance literature. The importance of osmolality and volume are emphasized when discussing the physiology, assessment, and performance effects of dehydration. The underappreciated physiologic distinction between a loss of hypo-osmotic body water (intracellular dehydration) and an iso-osmotic loss of body water (extracellular dehydration) is presented and argued as the single most essential aspect of dehydration assessment. The importance of diagnostic and biological variation analyses to dehydration assessment methods is reviewed and their use in gauging the true potential of any dehydration assessment method highlighted. The necessity for establishing proper baselines is discussed, as is the magnitude of dehydration required to elicit reliable and detectable osmotic or volume-mediated compensatory physiologic responses. The discussion of physiologic responses further helps inform and explain our analysis of the literature suggesting a ≥ 2% dehydration threshold for impaired endurance exercise performance mediated by volume loss. In contrast, no clear threshold or plausible mechanism(s) support the marginal, but potentially important, impairment in strength, and power observed with dehydration. Similarly, the potential for dehydration to impair cognition appears small and related primarily to distraction or discomfort. The impact of dehydration on any particular sport skill or task is therefore likely dependent upon the makeup of the task itself (e.g., endurance, strength, cognitive, and motor skill).

328 citations

Journal ArticleDOI
01 Oct 2012-Chest
TL;DR: LUS is a noninvasive, usually available tool used for high-accuracy diagnosis of CAP and about 8% of pneumonic lesions are not detectable by LUS; therefore, an inconspicuous LUS does not exclude pneumonia.

296 citations


Additional excerpts

  • ...Lung ultrasound (LUS) represents a new technique for diagnosing pleural and pulmonary diseases [3-9]....

    [...]

Journal ArticleDOI
TL;DR: Evidence-based guidelines for the use of POCUS in critically ill neonates and children are now available and will be useful to optimise the use, training programs and further research, which are urgently needed given the weak quality of evidence available.
Abstract: Point-of-care ultrasound (POCUS) is nowadays an essential tool in critical care. Its role seems more important in neonates and children where other monitoring techniques may be unavailable. POCUS Working Group of the European Society of Paediatric and Neonatal Intensive Care (ESPNIC) aimed to provide evidence-based clinical guidelines for the use of POCUS in critically ill neonates and children. Creation of an international Euro-American panel of paediatric and neonatal intensivists expert in POCUS and systematic review of relevant literature. A literature search was performed, and the level of evidence was assessed according to a GRADE method. Recommendations were developed through discussions managed following a Quaker-based consensus technique and evaluating appropriateness using a modified blind RAND/UCLA voting method. AGREE statement was followed to prepare this document. Panellists agreed on 39 out of 41 recommendations for the use of cardiac, lung, vascular, cerebral and abdominal POCUS in critically ill neonates and children. Recommendations were mostly (28 out of 39) based on moderate quality of evidence (B and C). Evidence-based guidelines for the use of POCUS in critically ill neonates and children are now available. They will be useful to optimise the use of POCUS, training programs and further research, which are urgently needed given the weak quality of evidence available.

258 citations

References
More filters
Journal ArticleDOI
TL;DR: The facts are summarized about CT scans, which involve much higher doses of radiation than plain films, and the implications for public health are summarized.
Abstract: The number of computed tomographic (CT) studies performed is increasing rapidly. Because CT scans involve much higher doses of radiation than plain films, we are seeing a marked increase in radiation exposure in the general population. Epidemiologic studies indicate that the radiation dose from even two or three CT scans results in a detectable increase in the risk of cancer, especially in children. This article summarizes the facts about this form of radiation exposure and the implications for public health.

7,601 citations

01 Jan 2001
TL;DR: This project aimed to collect and critically review the existing evidence on practices relevant to improving patient safety and identify practices with the strongest supporting evidence that decrease the risks associated with hospitalization, critical care, or surgery.
Abstract: Objectives Patient safety has received increased attention in recent years, but mostly with a focus on the epidemiology of errors and adverse events, rather than on practices that reduce such events This project aimed to collect and critically review the existing evidence on practices relevant to improving patient safety Search strategy and selection criteria Patient safety practices were defined as those that reduce the risk of adverse events related to exposure to medical care across a range of diagnoses or conditions Potential patient safety practices were identified based on preliminary surveys of the literature and expert consultation This process resulted in the identification of 79 practices for review The practices focused primarily on hospitalized patients, but some involved nursing home or ambulatory patients Protocols specified the inclusion criteria for studies and the structure for evaluation of the evidence regarding each practice Pertinent studies were identified using various bibliographic databases (eg, MEDLINE, PsycINFO, ABI/INFORM, INSPEC), targeted searches of the Internet, and communication with relevant experts Data collection and analysis Included literature consisted of controlled observational studies, clinical trials and systematic reviews found in the peer-reviewed medical literature, relevant non-health care literature and "gray literature" For most practices, the project team required that the primary outcome consist of a clinical endpoint (ie, some measure of morbidity or mortality) or a surrogate outcome with a clear connection to patient morbidity or mortality This criterion was relaxed for some practices drawn from the non-health care literature The evidence supporting each practice was summarized using a prospectively determined format The project team then used a predefined consensus technique to rank the practices according to the strength of evidence presented in practice summaries A separate ranking was developed for research priorities Main results Practices with the strongest supporting evidence are generally clinical interventions that decrease the risks associated with hospitalization, critical care, or surgery Many patient safety practices drawn primarily from nonmedical fields (eg, use of simulators, bar coding, computerized physician order entry, crew resource management) deserve additional research to elucidate their value in the health care environment The following 11 practices were rated most highly in terms of strength of the evidence supporting more widespread implementation Appropriate use of prophylaxis to prevent venous thromboembolism in patients at risk; Use of perioperative beta-blockers in appropriate patients to prevent perioperative morbidity and mortality; Use of maximum sterile barriers while placing central intravenous catheters to prevent infections; Appropriate use of antibiotic prophylaxis in surgical patients to prevent postoperative infections; Asking that patients recall and restate what they have been told during the informed consent process; Continuous aspiration of subglottic secretions (CASS) to prevent ventilator-associated pneumonia; Use of pressure relieving bedding materials to prevent pressure ulcers; Use of real-time ultrasound guidance during central line insertion to prevent complications; Patient self-management for warfarin (Coumadin) to achieve appropriate outpatient anticoagulation and prevent complications; Appropriate provision of nutrition, with a particular emphasis on early enteral nutrition in critically ill and surgical patients; and Use of antibiotic-impregnated central venous catheters to prevent catheter-related infections Conclusions An evidence-based approach can help identify practices that are likely to improve patient safety Such practices target a diverse array of safety problems Further research is needed to fill the substantial gaps in the evidentiary base, particularly with regard to the generalizability of patient safety practices heretofore tested only in limited settings and to promising practices drawn from industries outside of health care

1,556 citations

Journal ArticleDOI
14 Aug 2003-BMJ
TL;DR: Evidence supports the use of two dimensional ultrasonography for central venous cannulation in adults and in infants.
Abstract: Objectives To assess the evidence for the clinical effectiveness of ultrasound guided central venous cannulation. Data sources 15 electronic bibliographic databases, covering biomedical, science, social science, health economics, and grey literature. Design Systematic review and meta-analysis of randomised controlled trials. Populations Patients scheduled for central venous access. Intervention reviewed Guidance using real time two dimensional ultrasonography or Doppler needles and probes compared with the anatomical landmark method of cannulation. Data extraction Risk of failed catheter placement (primary outcome), risk of complications from placement, risk of failure on first attempt at placement, number of attempts to successful catheterisation, and time (seconds) to successful catheterisation. Data synthesis 18 trials (1646 participants) were identified. Compared with the landmark method, real time two dimensional ultrasound guidance for cannulating the internal jugular vein in adults was associated with a significantly lower failure rate both overall (relative risk 0.14, 95% confidence interval 0.06 to 0.33) and on the first attempt (0.59, 0.39 to 0.88). Limited evidence favoured two dimensional ultrasound guidance for subclavian vein and femoral vein procedures in adults (0.14, 0.04 to 0.57 and 0.29, 0.07 to 1.21, respectively). Three studies in infants confirmed a higher success rate with two dimensional ultrasonography for internal jugular procedures (0.15, 0.03 to 0.64). Doppler guided cannulation of the internal jugular vein in adults was more successful than the landmark method (0.39, 0.17 to 0.92), but the landmark method was more successful for subclavian vein procedures (1.48, 1.03 to 2.14). No significant difference was found between these techniques for cannulation of the internal jugular vein in infants. An indirect comparison of relative risks suggested that two dimensional ultrasonography would be more successful than Doppler guidance for subclavian vein procedures in adults (0.09, 0.02 to 0.38). Conclusions Evidence supports the use of two dimensional ultrasonography for central venous cannulation.

1,024 citations

Journal ArticleDOI
TL;DR: Tomodensitometric correlations showed that the thickened sub-pleural interlobular septa, as well as ground-glass areas, two lesions present in acute pulmonary edema, were associated with the presence of the comet-tail artifact.
Abstract: Can ultrasound be of any help in the diagnosis of alveolar-interstitial syndrome? In a prospective study, we examined 250 consecutive patients in a medical intensive care unit: 121 patients with radiologic alveolar-interstitial syndrome (disseminated to the whole lung, n = 92; localized, n = 29) and 129 patients without radiologic evidence of alveolar-interstitial syndrome. The antero-lateral chest wall was examined using ultrasound. The ultrasonic feature of multiple comet-tail artifacts fanning out from the lung surface was investigated. This pattern was present all over the lung surface in 86 of 92 patients with diffuse alveolar-interstitial syndrome (sensitivity of 93.4%). It was absent or confined to the last lateral intercostal space in 120 of 129 patients with normal chest X-ray (specificity of 93.0%). Tomodensitometric correlations showed that the thickened sub-pleural interlobular septa, as well as ground-glass areas, two lesions present in acute pulmonary edema, were associated with the presence of the comet-tail artifact. In conclusion, presence of the comet-tail artifact allowed diagnosis of alveolar-interstitial syndrome.

947 citations

Related Papers (5)