Test-retest reliability of the electromyographic fatigue threshold for cycle ergometry.
Citations
248 citations
18 citations
18 citations
Cites background from "Test-retest reliability of the elec..."
...It has been shown that the EMGFT is a highly reliable measure (24)....
[...]
8 citations
Cites background or result from "Test-retest reliability of the elec..."
...Consistent with previous studies (3,10,11,19,24), the EMG signal before and after the contraction was analyzed to determine if interelectrode impedance was below 2,000 ohms....
[...]
...85) (19) and influenced by caffeine supplementation (24)....
[...]
...Studies have reported that the EMGFT for cycle ergometry (5,19) range between ;63 and ;69% of the maximal power output, which is indicative of submaximal exercise intensity....
[...]
...Moreover, it has been shown that the EMGFT is a highly reliable measure (19)....
[...]
...The electrodes were placed at 50% the distance between the anterior superior iliac spine and the superior border of the patella (3,10,11,14,19,24)....
[...]
7 citations
References
43,884 citations
21,185 citations
"Test-retest reliability of the elec..." refers background in this paper
...In addition to the ICC, another commonly reported statistic is the standard error of measurement (SEM), which indicates the expected trial-to-trial noise for the variable of interest.(15,16) Both ICC and SEM are important indices, because they provide a measure of stability for the desired variable as well as the error associated with that variable....
[...]
...The ICC is interpreted as a measure of variance attributed to the target being measured.(14,15) Therefore, the target may be endurance athletes, cardiac patients, or rats, whereas the measurement may be time to exhaustion, EMG amplitude, or peak torque....
[...]
5,858 citations
"Test-retest reliability of the elec..." refers background in this paper
...The ICC is interpreted as a measure of variance attributed to the target being measured.(14,15) Therefore, the target may be endurance athletes, cardiac patients, or rats, whereas the measurement may be time to exhaustion, EMG amplitude, or peak torque....
[...]
5,044 citations
"Test-retest reliability of the elec..." refers background or methods in this paper
...The electrodes for the VL were placed over the lateral portion of the muscle approximately two-thirds the distance from the head of the greater trochanter and the lateral condyle of the femur.(17) For the RF, the electrodes were placed at one-half the distance from the inguinal crease and the superior border of the patella....
[...]
...The electrode placement for the VM was one-fifth of the distance between the medial gap of the knee joint and the anterior superior iliac spine of the pelvis.(17) The shaved skin at each electrode site was abraded carefully, cleaned with alcohol, and interelectrode impedance was kept at <2,000 X....
[...]
..., Santa Barbara, California) placed on the vastus lateralis (VL), rectus femoris (RF), and vastus medialis (VM) muscles using standard guidelines.(17) The electrodes for the VL were placed over the lateral portion of the muscle approximately two-thirds the distance from the head of the greater trochanter and the lateral condyle of the femur....
[...]
...For the RF, the electrodes were placed at one-half the distance from the inguinal crease and the superior border of the patella.(17) The electrode placement for the VM was one-fifth of the distance between the medial gap of the knee joint and the anterior superior iliac spine of the pelvis....
[...]