scispace - formally typeset
Search or ask a question
Journal ArticleDOI

The analysis of angular correlation and angular distribution data

01 Aug 1953-Physical Review (American Physical Society)-Vol. 91, Iss: 3, pp 610-615
TL;DR: In this article, a number of problems arising in the analysis of angular correlation and angular distribution data are considered, including corrections for finite angular resolution, and a brief discussion of the corrections for a decaying source.
Abstract: Consideration of a number of problems which arise in the analysis of angular correlation and angular distribution data is given. These include corrections for finite angular resolution. For a source of constant strength the questions of determination of most probable counting rates, their associated errors and the determination of the most probable coefficients in the Legendre representation of the data, as well as the errors in the determination of these coefficients, are examined. A brief discussion of the corrections for a decaying source is also presented.
Citations
More filters
Journal ArticleDOI
TL;DR: Two general procedures for the measurement and analysis of angular correlations of gamma radiations from nuclear reactions are described in this article, which have wide applications in nuclear spectroscopy for the detection of nuclear reactions.
Abstract: Two general procedures for the measurement and analysis of angular correlations of gamma radiations from nuclear reactions are described which have wide applications in nuclear spectroscopy for the...

283 citations

Journal ArticleDOI
TL;DR: In this article, the average level spacing in slow neutron total cross sections is estimated using the resonances of the total cross section of the slow neutrons in the medium and heavy nuclei.
Abstract: Recent measurements of resonances in slow neutron total cross sections yield good estimates of the average level spacing, D, in medium and heavy nuclei. These spacings show large variations, by fac...

265 citations

Journal ArticleDOI
TL;DR: Finite solid-angle corrections for Ge(Li) detectors have been calculated for source distances of 3.0, 5.0, 7.0 and 10.0 cm.

197 citations

Journal ArticleDOI
TL;DR: In this paper, a method for computing the finite solid-angle correction factors for coaxial Ge(Li) detectors is presented, in particular the correction factors Q k for odd k. The computer program employed for the calculation, and the results of the calculation are compared with experimental values.

93 citations

Journal ArticleDOI
TL;DR: In this paper, the authors measured the lifetimes of gamma rays from O/sup 18/ and F/sup18/ using the Doppler shift attenuation method and found that the mean lifetimes in psec of the 1.98m 3,55m 4,63m 3.92m abd 4,45-Mev levels in O/Sup 18/ were found to be 3.7 plus or minus 0.

78 citations