scispace - formally typeset
Search or ask a question
Journal ArticleDOI

The International Registry of Acute Aortic Dissection (IRAD): new insights into an old disease.

TL;DR: The data support the need for continued improvement in prevention, diagnosis, and management of acute aortic dissection and suggest a high clinical index of suspicion is necessary.
Abstract: ContextAcute aortic dissection is a life-threatening medical emergency associated with high rates of morbidity and mortality. Data are limited regarding the effect of recent imaging and therapeutic advances on patient care and outcomes in this setting.ObjectiveTo assess the presentation, management, and outcomes of acute aortic dissection.DesignCase series with patients enrolled between January 1996 and December 1998. Data were collected at presentation and by physician review of hospital records.SettingThe International Registry of Acute Aortic Dissection, consisting of 12 international referral centers.ParticipantsA total of 464 patients (mean age, 63 years; 65.3% male), 62.3% of whom had type A dissection.Main Outcome MeasuresPresenting history, physical findings, management, and mortality, as assessed by history and physician review of hospital records.ResultsWhile sudden onset of severe sharp pain was the single most common presenting complaint, the clinical presentation was diverse. Classic physical findings such as aortic regurgitation and pulse deficit were noted in only 31.6% and 15.1% of patients, respectively, and initial chest radiograph and electrocardiogram were frequently not helpful (no abnormalities were noted in 12.4% and 31.3% of patients, respectively). Computed tomography was the initial imaging modality used in 61.1%. Overall in-hospital mortality was 27.4%. Mortality of patients with type A dissection managed surgically was 26%; among those not receiving surgery (typically because of advanced age and comorbidity), mortality was 58%. Mortality of patients with type B dissection treated medically was 10.7%. Surgery was performed in 20% of patients with type B dissection; mortality in this group was 31.4%.ConclusionsAcute aortic dissection presents with a wide range of manifestations, and classic findings are often absent. A high clinical index of suspicion is necessary. Despite recent advances, in-hospital mortality rates remain high. Our data support the need for continued improvement in prevention, diagnosis, and management of acute aortic dissection.
Citations
More filters
Journal ArticleDOI
TL;DR: It is essential that the medical profession play a central role in critically evaluating the evidence related to drugs, devices, and procedures for the detection, management, or prevention of disease.

1,492 citations

Journal ArticleDOI
TL;DR: Autores/Miembros del Grupo de Trabajo: Raimund Erbel ( coordinador) (Alemania), Victor Aboyans (Coordinado) ( Francia), Catherine Boileau (Francia), Eduardo Bossone (Italia), Roberto Di Bartolomeo (It Italy), Holger Eggebrecht (AleGermany)
Abstract: Autores/Miembros del Grupo de Trabajo: Raimund Erbel (Coordinador) (Alemania), Victor Aboyans (Coordinador) (Francia), Catherine Boileau (Francia), Eduardo Bossone (Italia), Roberto Di Bartolomeo (Italia), Holger Eggebrecht (Alemania), Arturo Evangelista (Espana), Volkmar Falk (Suiza), Herbert Frank (Austria), Oliver Gaemperli (Suiza), Martin Grabenwoger (Austria), Axel Haverich (Alemania), Bernard Iung (Francia), Athanasios John Manolis (Grecia), Folkert Meijboom (Paises Bajos), Christoph A. Nienaber (Alemania), Marco Roffi (Suiza), Herve Rousseau (Francia), Udo Sechtem (Alemania), Per Anton Sirnes (Noruega), Regula S. von Allmen (Suiza) y Christiaan J.M. Vrints (Belgica)

963 citations

References
More filters
Journal ArticleDOI
TL;DR: Pressures in the right side of the heart and pulmonary capillary wedge can be obtained by cardiac catheterization without the aid of fluoroscopy.
Abstract: Pressures in the right side of the heart and pulmonary capillary wedge can be obtained by cardiac catheterization without the aid of fluoroscopy. A No. 5 Fr double-lumen catheter with a balloon just proximal to the tip is inserted into the right atrium under pressure monitoring. The balloon is then inflated with 0.8 ml of air. The balloon is carried by blood flow through the right side of the heart into the smaller radicles of the pulmonary artery. In this position when the balloon is inflated wedge pressure is obtained. The average time for passage of the catheter from the right atrium to the pulmonary artery was 35 seconds in the first 100 passages. The frequency of premature beats was minimal, and no other arrhythmias occurred.

1,927 citations


"The International Registry of Acute..." refers background in this paper

  • ...Since Debakey first reported surgical repair of a thoracic aortic aneurysm, management techniques have steadily advanced.(5-14) Recently, percutaneous fenestration and/or stent placement have been used in select patients....

    [...]

Journal ArticleDOI
TL;DR: Stent-graft coverage of the primary entry tear may be a promising new treatment for selected patients with acute aortic dissection and requires further evaluation, however, to assess its therapeutic potential fully.
Abstract: Background The standard treatment for acute aortic dissection is either surgical or medical therapy, depending on the morphologic features of the lesion and any associated complications. Irrespective of the form of treatment, the associated mortality and morbidity are considerable. Methods We studied the placement of endovascular stent–grafts across the primary entry tear for the management of acute aortic dissection originating in the descending thoracic aorta. We evaluated the feasibility, safety, and effectiveness of transluminal stent–graft placement over the entry tear in 4 patients with acute type A aortic dissections (which involve the ascending aorta) and 15 patients with acute type B aortic dissections (which are confined to the descending aorta). Dissections involved aortic branches in 14 of the 19 patients (74 percent), and symptomatic compromise of multiple branch vessels was observed in 7 patients (37 percent). The stent–grafts were made of self-expanding stainless-steel covered with woven po...

1,158 citations


"The International Registry of Acute..." refers methods in this paper

  • ...Recently, percutaneous fenestration and/or stent placement have been used in select patients.(15-19) Similarly, diagnostic imaging modalities, including computed tomography, transesophageal echocardiography, and magnetic resonance imaging, have been developed and are widely available....

    [...]

Journal ArticleDOI

1,018 citations


"The International Registry of Acute..." refers background in this paper

  • ...Stanford type A dissections involve the ascending aorta and type B dissections occur distal to the left subclavian artery.(36) The 14-day period after onset has been designated the acute phase, because morbidity and mortality rates are highest and surviving patients typicallystabilizeduring this time....

    [...]

Journal ArticleDOI
TL;DR: These preliminary observations suggest that elective, nonsurgical insertion of an endovascular stent-graft is safe and efficacious in selected patients who have thoracic aortic dissection and for whom surgery is indicated.
Abstract: Background The treatment of thoracic aortic dissection is guided by prognostic and anatomical information. Proximal dissection requires surgery, but the appropriate treatment of distal thoracic aortic dissection has not been determined, because surgery has failed to improve the prognosis. Methods We prospectively evaluated the safety and efficacy of elective transluminal endovascular stent–graft insertion in 12 consecutive patients with descending (type B) aortic dissection and compared the results with surgery in 12 matched controls. In all 24 patients, aortic dissection was diagnosed by magnetic resonance angiography. In each group, the dissection involved the aortic arch in 3 patients and the descending thoracic aorta in all 12 patients. With the patient under general anesthesia, either surgical resection was undertaken or a custom-designed endovascular stent–graft was placed by unilateral arteriotomy. Results Stent–graft placement resulted in no morbidity or mortality, whereas surgery for type B disse...

971 citations