scispace - formally typeset
Search or ask a question

The rise of low-cost sensing for managing air pollution in cities

TL;DR: In this article, the authors illustrate the drivers behind current rises in the use of low-cost sensors for air pollution management in cities, whilst addressing the major challenges for their effective implementation.
Abstract: Ever growing populations in cities are associated with a major increase in road vehicles and air pollution. The overall high levels of urban air pollution have been shown to be of a significant risk to city dwellers. However, the impacts of very high but temporally and spatially restricted pollution, and thus exposure, are still poorly understood. Conventional approaches to air quality monitoring are based on networks of static and sparse measurement stations. However, these are prohibitively expensive to capture tempo-spatial heterogeneity and identify pollution hotspots, which is required for the development of robust real-time strategies for exposure control. Current progress in developing low-cost micro-scale sensing technology is radically changing the conventional approach to allow real-time information in a capillary form. But the question remains whether there is value in the less accurate data they generate. This article illustrates the drivers behind current rises in the use of low-cost sensors for air pollution management in cities, whilst addressing the major challenges for their effective implementation.
Citations
More filters
01 Jul 2018
TL;DR: In this article, the authors conducted a comprehensive literature search including both the scientific and grey literature, and concluded that there is no clear answer to the question, due to a lack of: sensor/monitor manufacturers' quantitative specifications of performance, consensus regarding recommended end-use and associated minimal performance targets of these technologies, and the ability of the prospective users to formulate the requirements for their applications, or conditions of the intended use.
Abstract: Over the past decade, a range of sensor technologies became available on the market, enabling a revolutionary shift in air pollution monitoring and assessment. With their cost of up to three orders of magnitude lower than standard/reference instruments, many avenues for applications have opened up. In particular, broader participation in air quality discussion and utilisation of information on air pollution by communities has become possible. However, many questions have been also asked about the actual benefits of these technologies. To address this issue, we conducted a comprehensive literature search including both the scientific and grey literature. We focused upon two questions: (1) Are these technologies fit for the various purposes envisaged? and (2) How far have these technologies and their applications progressed to provide answers and solutions? Regarding the former, we concluded that there is no clear answer to the question, due to a lack of: sensor/monitor manufacturers' quantitative specifications of performance, consensus regarding recommended end-use and associated minimal performance targets of these technologies, and the ability of the prospective users to formulate the requirements for their applications, or conditions of the intended use. Numerous studies have assessed and reported sensor/monitor performance under a range of specific conditions, and in many cases the performance was concluded to be satisfactory. The specific use cases for sensors/monitors included outdoor in a stationary mode, outdoor in a mobile mode, indoor environments and personal monitoring. Under certain conditions of application, project goals, and monitoring environments, some sensors/monitors were fit for a specific purpose. Based on analysis of 17 large projects, which reached applied outcome stage, and typically conducted by consortia of organizations, we observed that a sizable fraction of them (~ 30%) were commercial and/or crowd-funded. This fact by itself signals a paradigm change in air quality monitoring, which previously had been primarily implemented by government organizations. An additional paradigm-shift indicator is the growing use of machine learning or other advanced data processing approaches to improve sensor/monitor agreement with reference monitors. There is still some way to go in enhancing application of the technologies for source apportionment, which is of particular necessity and urgency in developing countries. Also, there has been somewhat less progress in wide-scale monitoring of personal exposures. However, it can be argued that with a significant future expansion of monitoring networks, including indoor environments, there may be less need for wearable or portable sensors/monitors to assess personal exposure. Traditional personal monitoring would still be valuable where spatial variability of pollutants of interest is at a finer resolution than the monitoring network can resolve.

138 citations

Journal Article
TL;DR: Forouzanfar et al. as discussed by the authors provide a review of the new air pollution sensing methods to determine indoor air quality and discuss how real-time sensing could bring a paradigm shift in controlling the concentration of key air pollutants in billions of urban houses worldwide.
Abstract: Household air pollution is ranked the 9th largest Global Burden of Disease risk (Forouzanfar et al., The Lancet 2015). People, particularly urban dwellers, typically spend over 90% of their daily time indoors, where levels of air pollution often surpass those of outdoor environments. Indoor air quality (IAQ) standards and approaches for assessment and control of indoor air require measurements of pollutant concentrations and thermal comfort using conventional instruments. However, the outcomes of such measurements are usually averages over long integrated time periods, which become available after the exposure has already occurred. Moreover, conventional monitoring is generally incapable of addressing temporal and spatial heterogeneity of indoor air pollution, or providing information on peak exposures that occur when specific indoor sources are in operation. This article provides a review of the new air pollution sensing methods to determine IAQ and discusses how real-time sensing could bring a paradigm shift in controlling the concentration of key air pollutants in billions of urban houses worldwide. However, we also show that besides the opportunities, challenges still remain in terms of maturing technologies, or data mining and their interpretation. Moreover, we discuss further research and essential development needed to close gaps between what is available today and needed tomorrow. In particular, we demonstrate that awareness of IAQ risks and availability of appropriate regulation are lagging behind the technologies.

68 citations

Journal ArticleDOI
01 Jan 2022-Sensors
TL;DR: This article summarizes the existing studies on the state-of-the-art of LCS for AQM, and conceptualizes a step by step procedure to establish a sustainable AQM setup with LCS that can produce reliable data.
Abstract: Low-cost sensors (LCS) are becoming popular for air quality monitoring (AQM). They promise high spatial and temporal resolutions at low-cost. In addition, citizen science applications such as personal exposure monitoring can be implemented effortlessly. However, the reliability of the data is questionable due to various error sources involved in the LCS measurement. Furthermore, sensor performance drift over time is another issue. Hence, the adoption of LCS by regulatory agencies is still evolving. Several studies have been conducted to improve the performance of low-cost sensors. This article summarizes the existing studies on the state-of-the-art of LCS for AQM. We conceptualize a step by step procedure to establish a sustainable AQM setup with LCS that can produce reliable data. The selection of sensors, calibration and evaluation, hardware setup, evaluation metrics and inferences, and end user-specific applications are various stages in the LCS-based AQM setup we propose. We present a critical analysis at every step of the AQM setup to obtain reliable data from the low-cost measurement. Finally, we conclude this study with future scope to improve the availability of air quality data.

33 citations

01 Jan 2014
TL;DR: In this paper, the authors reviewed some fundamental drivers of UFP emissions and dispersion, and highlighted unresolved challenges, as well as recommendations to ensure sustainable urban development whilst minimising any possible adverse health impacts.
Abstract: Ultrafine particles (UFP; diameter less than 100 nm) are ubiquitous in urban air, and an acknowledged risk to human health. Globally, the major source for urban outdoor UFP concentrations is motor traffic. Ongoing trends towards urbanisation and expansion of road traffic are anticipated to further increase population exposure to UFPs. Numerous experimental studies have characterised UFPs in individual cities, but an integrated evaluation of emissions and population exposure is still lacking. Our analysis suggest that average exposure to outdoor UFPs in Asian cities is about four-times larger than those in European cities but impacts on human health are largely unknown. This article reviews some fundamental drivers of UFP emissions and dispersion, and highlights unresolved challenges, as well as recommendations to ensure sustainable urban development whilst minimising any possible adverse health impacts.

32 citations

01 Jun 2016
TL;DR: In this paper, a taxi fleet of over 15,000 vehicles was analyzed with the aim of predicting air pollution emissions for Singapore, and the results showed that highly localized areas of elevated emissions levels were identified, with a spatio-temporal precision not possible with previously used methods for estimating emissions.
Abstract: Air pollution related to traffic emissions pose an especially significant problem in cities; this is due to its adverse impact on human health and well-being. Previous studies which have aimed to quantify emissions from the transportation sector have been limited by either simulated or coarsely resolved traffic volume data. Emissions inventories form the basis of urban pollution models, therefore in this study, Global Positioning System (GPS) trajectory data from a taxi fleet of over 15,000 vehicles were analyzed with the aim of predicting air pollution emissions for Singapore. This novel approach enabled the quantification of instantaneous drive cycle parameters in high spatio-temporal resolution, which provided the basis for a microscopic emissions model. Carbon dioxide (CO2), nitrogen oxides (NOx), volatile organic compounds (VOCs) and particulate matter (PM) emissions were thus estimated. Highly localized areas of elevated emissions levels were identified, with a spatio-temporal precision not possible with previously used methods for estimating emissions. Relatively higher emissions areas were mainly concentrated in a few districts that were the Singapore Downtown Core area, to the north of the central urban region and to the east of it. Daily emissions quantified for the total motor vehicle population of Singapore were found to be comparable to another emissions dataset. Results demonstrated that high-resolution spatio-temporal vehicle traces detected using GPS in large taxi fleets could be used to infer highly localized areas of elevated acceleration and air pollution emissions in cities, and may become a complement to traditional emission estimates, especially in emerging cities and countries where reliable fine-grained urban air quality data is not easily available. This is the first study of its kind to investigate measured microscopic vehicle movement in tandem with microscopic emissions modeling for a substantial study domain.

21 citations

References
More filters
Proceedings ArticleDOI
17 Jun 2018
TL;DR: In this paper, a laboratory evaluation of commercially available electrochemical gas sensors for the monitoring of CO in ambient air is presented, and six commercial electrochemical CO sensors were tested simultaneously under controlled gas concentrations and various environmental conditions.
Abstract: Air pollution is a growing concern of civilized world, which has a significant impact on human health and the environment. Recent studies highlight that the exposure to polluted air can increase the incidence of diseases and deteriorate the quality of life. Hence, it is necessary to develop tools for real-time air quality monitoring. For air pollution monitoring a wide range of stationary gas and particulate analysers can be used. However, such instruments are relatively large, heavy and expensive. Only governments, local authorities and major industries can afford to use such devices. Instruments based on low cost gas sensors can be interesting and promising alternative. However, real-life usage of gas sensors in monitoring outdoor air is connected with several challenges, such as temperature or humidity changes affecting sensor response. In this study, a laboratory evaluation of commercially available electrochemical gas sensors for the monitoring of CO in ambient air is presented. Six commercial electrochemical CO sensors were tested simultaneously under controlled gas concentrations and various environmental conditions.

3 citations

Journal ArticleDOI
TL;DR: In this paper, the authors describe the integration of data collection, analysis, and design output via a live interface using parametric software Rhino Grasshopper and the Human User Interface (UI) plugin.
Abstract: pedestrian and bicycle oriented modes for healthy living, downtown streets are becoming more attractive places to live. However, tools and methods to measure the natural environment at the small scale of streets do not exist. Fortunately, a combination of mobile data collection technology and parametric urban design software now allows an interface to relate urban ecological conditions. This paper describes creation of an interactive tool to measure urban phenomena of air, water, and heat/light at the scale of new three-by-three block pedestrianized areas in Barcelona called Superilles. Each Superilla limits transit to the exterior of the blocks and to create more walkable and bikeable interior streets for healthy living. The research will describe the integration of data collection, analysis, and design output via a live interface using parametric software Rhino Grasshopper and the Human User Interface (UI) plugin.

3 citations

Book ChapterDOI
01 Jan 2021
TL;DR: In this article, the authors proposed a wireless sensor network (WSN) based approach to environmental monitoring, allowing for the capture of real-time information in a capillary form.
Abstract: The evergrowing populations and increasing human activities are associated with a major increase in environmental pollution. However, their impact is still poorly understood due to the pervasiveness and spatiotemporal complexity of the phenomenon. Conventional approaches to environmental monitoring are based on networks of sparse measurement stations or in situ human-operated measurements. However, these are prohibitively expensive to capture the spatiotemporal heterogeneity of most of the environmental pollution phenomenon. Current advancements in the wireless sensor network (WSN) technology are radically changing the conventional approach, allowing for the capture of real-time information in a capillary form.

3 citations

Journal ArticleDOI
TL;DR: In this article, an ensemble of three low-cost stations named "AirQino" was deployed to monitor particulate matter (PM) concentrations over three different sites in an area affected by poor air quality conditions.
Abstract: Low-cost air quality stations can provide useful data that can offer a complete picture of urban air quality dynamics, especially when integrated with daily measurements from reference air quality stations. However, the success of such deployment depends on the measurement accuracy and the capability of resolving spatial and temporal gradients within a spatial domain. In this work, an ensemble of three low-cost stations named “AirQino” was deployed to monitor particulate matter (PM) concentrations over three different sites in an area affected by poor air quality conditions. Data of PM2.5 and PM10 concentrations were collected for about two years following a protocol based on field calibration and validation with a reference station. Results indicated that: (i) AirQino station measurements were accurate and stable during co-location periods over time (R2 = 0.5–0.83 and RMSE = 6.4–11.2 μg m−3; valid data: 87.7–95.7%), resolving current spatial and temporal gradients; (ii) spatial variability of anthropogenic emissions was mainly due to extensive use of wood for household heating; (iii) the high temporal resolution made it possible to detect time occurrence and strength of PM10 concentration peaks; (iv) the number of episodes above the 1-h threshold of 90 μg m−3 and their persistence were higher under urban and industrial sites compared to the rural area.

3 citations

Dissertation
01 Jan 2020
TL;DR: Evaluating air pollution exposure and the impacts of indoor air filtration using low-cost monitors by Karoline K. Johnson as mentioned in this paper was a part of the requirements for the degree of Doctor of Philosophy in the Department of Civil and Environmental Engineering in the Graduate School of Duke University 2018.
Abstract: Evaluating Air Pollutant Exposure and the Impacts of Indoor Air Filtration Using LowCost Monitors by Karoline K. Johnson Department of Civil and Environmental Engineering Duke University Date:_______________________ Approved: ___________________________ Michael Bergin, Supervisor ___________________________ Heather Stapleton ___________________________ Marc Deshusses ___________________________ Junfeng Zhang An abstract of a dissertation submitted in partial fulfillment of the requirements for the degree of Doctor of Philosophy in the Department of Civil and Environmental Engineering in the Graduate School of Duke University 2018 Copyright by Karoline K. Johnson 2018

3 citations