I. 1994-95 RUN SUMMARY
- The system has been remarkably reliable with <2% unscheduled downtime.
- The electron damping time is more critical.
- In the past, effort has been devoted to correcting transverse emittance dilution in the SLC bunch compressors [10-11].
IV. MAIN LINAC
- The main linac challenge is in high current emittance preservation and stabilization of both the e-and e+ bunches in the presence of the inevitable quadrupole and accelerating structure misalignments.
- The requirements for vertical linac emittance control have become even more challenging with the advent of flat beam operation in 1993 where the linac entrance emittance at 1.2 GeV is now: y~~ = 2-3 mm-mrad,.
DISCLAIMER
- Portions of this document may be illegible in electronic image products.
- This linac lattice modification successfully reduced evertical trajectory jitter from -GO% of the nominal rms beam size (observed in the final focus) to -40%.
- In response, magnet pitch wedges were installed for -2/3 of the linac quadrupoles.
- At the start of the run the emittance increase through the arcs was found to be independent of both beam current and initial emittance.
- Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof.
VI. FEEDBACK, CONTROLS AND DIAGNOSTICS
- There are approximately 28 different microprocessor controlled fast trajectory feedback loops, as well as several special function loops, in simultaneous operation around the SLC [37] .
- Furthermore, the loops are 'adaptive' meaning they are able to learn the transport mapthe accelerator transfer coefficients-between loops.
- An added benefit of adaptive-cascaded feedback is the continual measurement of the phase advance between points in the accelerator.
- The beginnings of significant progress in machine wide emittance control can be traced to the development and installation of beam profile wire-scanners in the main linac in 1990-91 [17] .
- The difference between 'design' and 1995 intensities alone, including associated loss in enhancement, accounts for a factor of -8 in luminosity.
VII. PRESENT PERFORMANCE LIMJTATIONS AND FUTURE PLANS Table
- The present peak performance parameten: are, however, not always maintainable.
- Some variations remain unexplained and are possibly due to an undiagnosed high current dilution mechanism within the collimation, arc or final focus systems.
- This appears to be current dependent and will be the main focus of attention in subsequent collider runs.
- Many smaller projects are in progress which address reliability issues and beam transmission limitations in the various transport lines.
Vm. ACKNOWLEDCMENTS
- The continuing progress in the performance of the SLC is in a large pIm due to the persistence of the operations staff who have leCmed and developed many new ways to deal with the full spectrum of problems encountered in daily operations.
- Further acknowledgments are extended to the SLC physicists, the engineering groups ' and the maintenance staff.
Did you find this useful? Give us your feedback
Citations
10 citations
Cites background from "The Stanford Linear Collider"
...The e+e− storage rings LEP at CERN [24] and SLC at SLAC [25] were designed to accelerate particles to centre-of-mass energies of larger than 90 GeV to produce large samples of Z-bosons....
[...]
9 citations
Cites methods from "The Stanford Linear Collider"
...During the 1994 SLC run [ 1 ] the beam intensities were limited to around 3.5x10 10 particles per bunch at the interaction point (IP) due to the increase of jitter with intensity....
[...]
6 citations
6 citations
References
116 citations
"The Stanford Linear Collider" refers background or methods in this paper
...The electron polarization has increased to 80% at the IP by using a 100 nm thin strained lattice GaAs photocathode in the electron source [2]....
[...]
...The polar ized electron source [2] presently uses a strained lattice GaAs photocathode which is biased at 120 kV and excited with circularly polarized light generated by a pulsed Ti:sapphire...
[...]
35 citations
35 citations
29 citations
26 citations