scispace - formally typeset
Open AccessJournal ArticleDOI

The Tension of Metallic Films Deposited by Electrolysis

George Gerald Stoney
- 06 May 1909 - 
- Vol. 82, Iss: 553, pp 172-175
Reads0
Chats0
TLDR
It is well known that metallic films deposited electrolytically are in many cases liable to peel off if deposited to any considerable thickness as discussed by the authors, especially if it does not adhere very tightly to the body on which it is deposited.
Abstract
It is well known that metallic films deposited electrolytically are in many cases liable to peel off if deposited to any considerable thickness. This is the case with nickel which, when deposited over a certain thickness, will curl up into beautiful close rolls, especially if it does not adhere very tightly to the body on which it is deposited. For example, if a piece of glass is silvered by any of the usual silvering solutions, and then nickel is deposited on the silver, it is found that the nickel and silver peel off the glass in close tight rolls almost at once. In ‘Practical Electro-Chemistry,' by Bertram Blount, reference is made on pp. 114 and 272 to the tendency of nickel to peel off, and it is stated that it “will peel—spontaneously and without assignable cause” (p. 272), but that a thick coating can be obtained by keeping the solution at between 50° and 90°C. The late Earl of Rosse tried, about 1865, to make flat mirrors by coating glass with silver chemically, and then electroplating with copper; but he found that, owing to the “contraction” of the copper film, it became detached from the glass. I have had the' same experience in protecting silver 61ms in searchlight reflectors by a film of electro-deposited copper, it being found that if the film of copper is more than 0.01 mm. thick peeling is apt to take place.

read more

Citations
More filters
Journal ArticleDOI

Cantilever transducers as a platform for chemical and biological sensors

TL;DR: In this article, the authors discuss sensors with transducers in a form of cantilevers, which are especially attractive as transducers for chemical and biological sensors, and provide a brief analysis of historical predecessors of the modern cantilever sensors.
Journal ArticleDOI

Comparative advantages of mechanical biosensors

TL;DR: The general issues that will be critical to the success of any type of next-generation mechanical biosensor are explained, such as the need to improve intrinsic device performance, fabrication reproducibility and system integration, and the need for a greater understanding of analyte-sensor interactions on the nanoscale.
Journal ArticleDOI

MEMS power generator with transverse mode thin film PZT

TL;DR: In this paper, a cantilever device is designed to have a flat structure with a proof mass added to the end to create electrical energy via the piezoelectric effect.
Journal ArticleDOI

Reversible calcium alloying enables a practical room-temperature rechargeable calcium-ion battery with a high discharge voltage.

TL;DR: A reversible calcium alloying/de-alloying reaction with the tin anode has been coupled with the intercalation/ de-intercalation of hexafluorophosphate in the graphite cathode to enable a calcium-ion battery that operates stably at room temperature.