scispace - formally typeset
Search or ask a question
Journal ArticleDOI

Theoretical and experimental investigations on horizontal heat pipe heat exchangers using a composite wick structure for heat recovery in air-conditioning systems

19 May 2017-Science and Technology for the Built Environment (Taylor & Francis)-Vol. 23, Iss: 4, pp 557-566
TL;DR: In this paper, theoretical and experimental analyses of horizontal heat pipe heat exchangers for air conditioning applications using distilled water as the working fluid were performed using 20 copper tubes of 9.5mm outside diameter arranged in two rows with a 0.3-m evaporator length, a condenser length, and 12 fins per inch of aluminum plate fins.
Abstract: The literature review indicates that, though water has a good figure of merit, very limited information is available on the use of water as the working fluid in a horizontal heat pipe heat exchanger for air conditioning applications. This article investigates theoretical and experimental analyses of horizontal heat pipe heat exchangers for air conditioning applications using distilled water as the working fluid. This heat pipe heat exchanger study consists of 20 copper tubes of 9.5 mm outside diameter arranged in two rows with a 0.3 m evaporator length, a 0.3 m condenser length, a 0.05 m adiabatic length, and 12 fins per inch of aluminum plate fins. A comparative analysis is studied for two configurations of heat pipe heat exchangers. The first configuration of heat pipe heat exchanger consists of a single wick structure with two layers of 180 mesh of phosphor bronze wire mesh, and, in the second configuration, the heat pipe heat exchanger consists of a composite wick structure (two layers of 180 mesh and...
Citations
More filters
Book
01 Nov 1985
TL;DR: Instrumentation, Measurement and Analysis, Instrumentation, measurement and analysis as mentioned in this paper, instrumentation, measurements and analysis, instrumentation and measurement, measurement, analysis and analysis.
Abstract: Instrumentation, Measurement and Analysis , Instrumentation, Measurement and Analysis , مرکز فناوری اطلاعات و اطلاع رسانی کشاورزی

80 citations

References
More filters
Journal Article
TL;DR: In this paper, an experimental study has been performed to investigate the thermal performance of a 2-row copper-R134a horizontal heat pipe heat exchanger in different working conditions.
Abstract: An experimental study has been performed to investigate the thermal performance of a 2-row copper-R134a horizontal heat pipe heat exchanger in different working conditions. During the tests, dry bulb temperature of evaporator inlet has been controlled at 27-35 C

6 citations

Journal ArticleDOI
TL;DR: In this paper, a numerical calculation of thermal performance and pressure drop for heat-pipe heat exchangers with aligned tube rows is presented and discussed, where the variation of the number of rows and columns from 1 to 6 for a total of 36 arrangements are presented.
Abstract: This paper presents a numerical calculation of thermal performance and pressure drop for heat-pipe heat exchangers with aligned tube rows. In this study the variation of the number of rows and columns from 1 to 6 for a total of 36 arrangements are presented and discussed. From the present results, an optimum arrangement of heat-pipe heat exchanger could be obtained.

4 citations