Transvascular endosonographic-guided needle biopsy of intrathoracic lesions.

01 May 2020-The Journal of Thoracic and Cardiovascular Surgery (J Thorac Cardiovasc Surg)-Vol. 159, Iss: 5, pp 2057-2065
TL;DR: Transvascular endosonographic-guided biopsy is an important adjunct to conventional endoscopic techniques and allows the thoracic endoscopist to obtain biopsy specimens from intrathoracic lesions that are not accessible without vascular puncture.
About: This article is published in The Journal of Thoracic and Cardiovascular Surgery.The article was published on 2020-05-01. It has received 17 citations till now. The article focuses on the topics: Biopsy & Endoscopic ultrasound.
Citations
More filters
Journal ArticleDOI
TL;DR: EUS-TV-FNA is feasible, seems to be safe, and can be recommended when no other targets are available, and the information obtained would impact on the clinical plan.
Abstract: Background and study aims Traditionally in the case of a vascular interposition, endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) has been contraindicated. A transvascular route (TV) is feasible and probably a safe alternative approach in selected patients, but data are scarce. The primary aim of this study was to analyze the diagnostic yield and safety of EUS-TV-FNA in thoracic and abdominal lesions. Secondary aims included evaluation of the clinical impact and technical aspects. Patients and methods A retrospective multicenter study was conducted with inclusion of all consecutive patients that underwent EUS-TV-FNA from July 2007 to January 2020. Feasibility, cytopathology, procedure details, and safety were evaluated. Univariate analysis was performed to identify variables associated with incidents, cytopathological diagnosis, and clinical impact. Results Data were collected from a total of 49 cases and 50 EUS-TV-FNAs. The aorta (n = 19) and portal system (n = 17) were the most frequently punctured. The most frequent lesions were mediastinal lymph nodes (n = 13) and pancreatic tumors (n = 11). The diagnostic yield was 86 %, and there were nondiagnostic samples in seven cases. Overall sensitivity, specificity, and accuracy were 88 % (95 %CI,0.74–0.96), 100 % (95 %CI,0.59–1), and 90 % (95 %CI,0.78–0.96), respectively. Only three incidents were detected: two mural hematomas and a self-limited bleeding of gastroduodenal artery. In most patients, there was a significant impact on clinical management (88 %). Arterial vessel and ASA-III had a trend with incidents (both, P Conclusions EUS-TV-FNA is feasible, seems to be safe, and can be recommended when no other targets are available, and the information obtained would impact on the clinical plan.

5 citations


Cites background from "Transvascular endosonographic-guide..."

  • ...One possible explanation for this lower diagnostic performance is that the number of passes made in a transvascular approach is less than with standard EUS-FNA, and this might affect sample adequacy [12]....

    [...]

  • ...One case of pseudo-aneurysm was detected 3 weeks after a transaortic EUS-FNA that was managed conservatively [4, 8, 12]....

    [...]

Journal ArticleDOI
TL;DR: In this article, the authors used EUS-B-guided fine-needle aspiration (FNA) to sample the left atrial masses, revealing a Burkitt lymphoma and a synovial sarcoma.
Abstract: Primary cardiac tumors are extremely rare. Obtaining a tissue diagnosis is difficult and commonly requires open-heart surgery with associated morbidity. Esophageal endoscopic ultrasound (EUS) and EUS with the EBUS scope (EUS-B) provide real-time sampling of centrally located lung tumors and mediastinal lymph nodes. They also provide an excellent view of the left atrium, since it is located adjacent to the esophagus. To date, left atrium tumor diagnostics by endosonography is poorly explored. We describe 2 exceptional diagnostic cases of left atrium tumors in which cardiac surgery was hazardous due to the clinical condition or previous surgical interventions. During EUS-B-guided fine-needle aspiration (FNA), the left atrial masses were successfully and safely sampled, revealing a Burkitt lymphoma and a synovial sarcoma. FNA including cell block analysis enabled specific tumor diagnosis and molecular subtyping. Our findings suggest that in selected cases, linear endosonography qualifies as a minimally invasive technique for intracardiac tumor diagnostics.

4 citations

References
More filters
Journal ArticleDOI
01 May 2013-Chest
TL;DR: It is demonstrated that PET scanning is more accurate than CT scanning, but tissue biopsy is still required to confirm PET scan findings, and evidence suggests that more complete staging improves patient outcomes.

1,167 citations

Journal ArticleDOI
24 Nov 2010-JAMA
TL;DR: Among patients with (suspected) NSCLC, a staging strategy combining endosonography and surgical staging compared with surgical staging alone resulted in greater sensitivity for mediastinal nodal metastases and fewer unnecessary thoracotomies.
Abstract: CONTEXT Mediastinal nodal staging is recommended for patients with resectable non-small cell lung cancer (NSCLC). Surgical staging has limitations, which results in the performance of unnecessary thoracotomies. Current guidelines acknowledge minimally invasive endosonography followed by surgical staging (if no nodal metastases are found by endosonography) as an alternative to immediate surgical staging. OBJECTIVE To compare the 2 recommended lung cancer staging strategies. DESIGN, SETTING, AND PATIENTS Randomized controlled multicenter trial (Ghent, Leiden, Leuven, Papworth) conducted between February 2007 and April 2009 in 241 patients with resectable (suspected) NSCLC in whom mediastinal staging was indicated based on computed or positron emission tomography. INTERVENTION Either surgical staging or endosonography (combined transesophageal and endobronchial ultrasound [EUS-FNA and EBUS-TBNA]) followed by surgical staging in case no nodal metastases were found at endosonography. Thoracotomy with lymph node dissection was performed when there was no evidence of mediastinal tumor spread. MAIN OUTCOME MEASURES The primary outcome was sensitivity for mediastinal nodal (N2/N3) metastases. The reference standard was surgical pathological staging. Secondary outcomes were rates of unnecessary thoracotomy and complications. RESULTS Two hundred forty-one patients were randomized, 118 to surgical staging and 123 to endosonography, of whom 65 also underwent surgical staging. Nodal metastases were found in 41 patients (35%; 95% confidence interval [CI], 27%-44%) by surgical staging vs 56 patients (46%; 95% CI, 37%-54%) by endosonography (P = .11) and in 62 patients (50%; 95% CI, 42%-59%) by endosonography followed by surgical staging (P = .02). This corresponded to sensitivities of 79% (41/52; 95% CI, 66%-88%) vs 85% (56/66; 95% CI, 74%-92%) (P = .47) and 94% (62/66; 95% CI, 85%-98%) (P = .02). Thoracotomy was unnecessary in 21 patients (18%; 95% CI, 12%-26%) in the mediastinoscopy group vs 9 (7%; 95% CI, 4%-13%) in the endosonography group (P = .02). The complication rate was similar in both groups. CONCLUSIONS Among patients with (suspected) NSCLC, a staging strategy combining endosonography and surgical staging compared with surgical staging alone resulted in greater sensitivity for mediastinal nodal metastases and fewer unnecessary thoracotomies. TRIAL REGISTRATION clinicaltrials.gov Identifier: NCT00432640.

536 citations

Journal ArticleDOI
TL;DR: Evaluated EBUS-TBNA is a safe and sensitive method for lymph node staging in patients with lung cancer which spares invasive staging procedures which has a major impact on patient management.

436 citations

Journal ArticleDOI
TL;DR: The results of this study demonstrate that bic Suspid valves induced significantly altered ascending aorta hemodynamics compared with age- and size-matched controls with tricuspid valves.
Abstract: Background— Hemodynamics may play a role contributing to the progression of bicuspid aortic valve (BAV) aortopathy. This study measured the impact of BAV on the distribution of regional aortic wall shear stress (WSS) compared with control cohorts. Methods and Results— Local WSS distribution was measured in the thoracic aorta of 60 subjects using 4-dimensional (4D) flow-sensitive magnetic resonance imaging. WSS analysis included 15 BAV patients: 12 with fusion of the right-left coronary cusp (6 stenotic) and 3 with fusion of the right and noncoronary cusp. The right-left BAV cohort was compared with healthy subjects (n=15), age-appropriate subjects (n=15), and age-/aorta size–controlled subjects (n=15). Compared with the age-appropriate and age-/aorta size–matched controls, WSS patterns in the right-left BAV ascending aorta were significantly elevated, independent of stenosis severity (peak WSS=0.9±0.3 N/m2 compared with 0.4±0.3 N/m2 in age-/aorta size–controlled subjects; P <0.001). Time-resolved (cine) 2D images of the bicuspid valves were coregistered with 4D flow data, directly linking cusp fusion pattern to a distinct ascending aortic flow jet pattern. The observation of right-anterior ascending aorta wall/jet impingement in right-left BAV patients corresponded to regions with statistically elevated WSS. Alternative jetting patterns were observed in the right and noncoronary cusp fusion patients. Conclusions— The results of this study demonstrate that bicuspid valves induced significantly altered ascending aorta hemodynamics compared with age- and size-matched controls with tricuspid valves. Specifically, the expression of increased and asymmetric WSS at the aorta wall was related to ascending aortic flow jet patterns, which were influenced by the BAV fusion pattern.

397 citations

Journal ArticleDOI
TL;DR: This work has shown that the non-linear elasticity of the artery wall is most pronounced in large whales, in which very high compliance in the aortic arch and exceptionally low Compliance in the descending aorta occur, and is correlated with specific modifications in the arterial structure.
Abstract: The most important mechanical property of the artery wall is its non-linear elasticity. Over the last century, this has been well-documented in vessels in many animals, from humans to lobsters. Arteries must be distensible to provide capacitance and pulse-smoothing in the circulation, but they must also be stable to inflation over a range of pressure. These mechanical requirements are met by strain-dependent increases in the elastic modulus of the vascular wall, manifest by a J-shaped stress-strain curve, as typically exhibited by other soft biological tissues. All vertebrates and invertebrates with closed circulatory systems have arteries with this non-linear behaviour, but specific tissue properties vary to give correct function for the physiological pressure range of each species. In all cases, the non-linear elasticity is a product of the parallel arrangement of rubbery and stiff connective tissue elements in the artery wall, and differences in composition and tissue architecture can account for the observed variations in mechanical properties. This phenomenon is most pronounced in large whales, in which very high compliance in the aortic arch and exceptionally low compliance in the descending aorta occur, and is correlated with specific modifications in the arterial structure.

380 citations

Related Papers (5)