Topic
Accelerometer
About: Accelerometer is a(n) research topic. Over the lifetime, 12340 publication(s) have been published within this topic receiving 170140 citation(s). The topic is also known as: acceleration sensor & g-sensor.
Papers published on a yearly basis
Papers
More filters
12 Aug 2011
TL;DR: This paper presents a novel orientation algorithm designed to support a computationally efficient, wearable inertial human motion tracking system for rehabilitation applications, applicable to inertial measurement units (IMUs) consisting of tri-axis gyroscopes and accelerometers, and magnetic angular rate and gravity sensor arrays that also include tri- axis magnetometers.
Abstract: This paper presents a novel orientation algorithm designed to support a computationally efficient, wearable inertial human motion tracking system for rehabilitation applications. It is applicable to inertial measurement units (IMUs) consisting of tri-axis gyroscopes and accelerometers, and magnetic angular rate and gravity (MARG) sensor arrays that also include tri-axis magnetometers. The MARG implementation incorporates magnetic distortion compensation. The algorithm uses a quaternion representation, allowing accelerometer and magnetometer data to be used in an analytically derived and optimised gradient descent algorithm to compute the direction of the gyroscope measurement error as a quaternion derivative. Performance has been evaluated empirically using a commercially available orientation sensor and reference measurements of orientation obtained using an optical measurement system. Performance was also benchmarked against the propriety Kalman-based algorithm of orientation sensor. Results indicate the algorithm achieves levels of accuracy matching that of the Kalman based algorithm; < 0.8° static RMS error, < 1.7° dynamic RMS error. The implications of the low computational load and ability to operate at small sampling rates significantly reduces the hardware and power necessary for wearable inertial movement tracking, enabling the creation of lightweight, inexpensive systems capable of functioning for extended periods of time.
1,482 citations
TL;DR: The calibration of four different accelerometers used most frequently to assess physical activity and sedentary behavior in children are reviewed and alternative data processing using the raw acceleration signal is recommended as a possible alternative approach where the actual acceleration pattern is used to characterize activity behavior.
Abstract: Understanding the determinants of physical activity behavior in children and youths is essential to the design and implementation of intervention studies to increase physical activity. Objective methods to assess physical activity behavior using various types of motion detectors have been recommended as an alternative to self-report for this population because they are not subject to many of the sources of error associated with children's recall required for self-report measures. This paper reviews the calibration of four different accelerometers used most frequently to assess physical activity and sedentary behavior in children. These accelerometers are the ActiGraph, Actical, Actiwatch, and the RT3 Triaxial Research Tracker. Studies are reviewed that describe the regression modeling approaches used to calibrate these devices using directly measured energy expenditure as the criterion. Point estimates of energy expenditure or count ranges corresponding to different activity intensities from several studies are presented. For a given accelerometer, the count cut points defining the boundaries for 3 and 6 METs vary substantially among the studies reviewed even though most studies include walking, running and free-living activities in the testing protocol. Alternative data processing using the raw acceleration signal is recommended as a possible alternative approach where the actual acceleration pattern is used to characterize activity behavior. Important considerations for defining best practices for accelerometer calibration in children and youths are presented.
983 citations
TL;DR: Preliminary evaluation of the system in 13 male subjects during standardized activities in the laboratory demonstrated a significant relationship between accelerometer output and energy expenditure due to physical activity, the standard reference for physical activity.
Abstract: The present study describes the development of a triaxial accelerometer (TA) and a portable data processing unit for the assessment of daily physical activity. The TA is composed of three orthogonally mounted uniaxial piezoresistive accelerometers and can be used to register accelerations covering the amplitude and frequency ranges of human body acceleration. Interinstrument and test-retest experiments showed that the offset and the sensitivity of the TA were equal for each measurement direction and remained constant on two measurement days. Transverse sensitivity was significantly different for each measurement direction, but did not influence accelerometer output (<3% of the sensitivity along the main axis). The data unit enables the on-line processing of accelerometer output to a reliable estimator of physical activity over eight-day periods. Preliminary evaluation of the system in 13 male subjects during standardized activities in the laboratory demonstrated a significant relationship between accelerometer output and energy expenditure due to physical activity, the standard reference for physical activity (r=0.89). Shortcomings of the system are its low sensitivity to sedentary activities and the inability to register static exercise. The validity of the system for the assessment of normal daily physical activity and specific activities outside the laboratory should be studied in free-living subjects.
919 citations
TL;DR: Using simulated falls performed under supervised conditions and activities of daily living performed by elderly subjects, the ability to discriminate between falls and ADL was investigated using tri-axial accelerometer sensors, mounted on the trunk and thigh.
Abstract: Using simulated falls performed under supervised conditions and activities of daily living (ADL) performed by elderly subjects, the ability to discriminate between falls and ADL was investigated using tri-axial accelerometer sensors, mounted on the trunk and thigh. Data analysis was performed using MATLAB to determine the peak accelerations recorded during eight different types of falls. These included; forward falls, backward falls and lateral falls left and right, performed with legs straight and flexed. Falls detection algorithms were devised using thresholding techniques. Falls could be distinguished from ADL for a total data set from 480 movements. This was accomplished using a single threshold determined by the fall-event data-set, applied to the resultant-magnitude acceleration signal from a tri-axial accelerometer located at the trunk.
768 citations
TL;DR: Improvements in the accuracy of orientation estimates are demonstrated for the proposed quaternion based extended Kalman filter, as compared with filter implementations where either the in-line calibration procedure, the adaptive mechanism for weighting the measurements of the aiding system sensors, or both are not implemented.
Abstract: In this paper, a quaternion based extended Kalman filter (EKF) is developed for determining the orientation of a rigid body from the outputs of a sensor which is configured as the integration of a tri-axis gyro and an aiding system mechanized using a tri-axis accelerometer and a tri-axis magnetometer. The suggested applications are for studies in the field of human movement. In the proposed EKF, the quaternion associated with the body rotation is included in the state vector together with the bias of the aiding system sensors. Moreover, in addition to the in-line procedure of sensor bias compensation, the measurement noise covariance matrix is adapted, to guard against the effects which body motion and temporary magnetic disturbance may have on the reliability of measurements of gravity and earth's magnetic field, respectively. By computer simulations and experimental validation with human hand orientation motion signals, improvements in the accuracy of orientation estimates are demonstrated for the proposed EKF, as compared with filter implementations where either the in-line calibration procedure, the adaptive mechanism for weighting the measurements of the aiding system sensors, or both are not implemented.
760 citations