scispace - formally typeset
Search or ask a question
Topic

Base load power plant

About: Base load power plant is a research topic. Over the lifetime, 6121 publications have been published within this topic receiving 96788 citations.


Papers
More filters
Journal ArticleDOI
01 Dec 2013-Energy
TL;DR: In this article, an attempt is made to classify the energy sources that can drive the ORC (organic Rankine cycle) power plants, and concepts of open and sealed type of energy sources are introduced as well as the difference between the energy source capacity and the energy supplied to the power plant cycle.

32 citations

Journal ArticleDOI
01 Nov 2016
TL;DR: In this paper, the authors present the runner strain gage measurement campaign of a mid-head Francis turbine over all the operating conditions available during the test, the analysis of the measurement signals and the runner residual life assessment under different operating scenarios.
Abstract: Traditionally, hydro power plants have been operated close to best efficiency point, the more stable operating condition for which they have been designed. However, because of changes in the electricity market, many hydro power plants operators wish to operate their machines differently to fulfil those new market needs. New operating conditions can include whole range operation, many start/stops, extensive low load operation, synchronous condenser mode and power/frequency regulation. Many of these new operating conditions may impose more severe fatigue damage than the traditional base load operation close to best efficiency point. Under these conditions, the fatigue life of the runner may be significantly reduced and reparation or replacement cost might occur sooner than expected. In order to design reliable Francis runners for those new challenging operating scenarios, Andritz Hydro has developed various proprietary tools and design rules. These are used within Andritz Hydro to design mechanically robust Francis runners for the operating scenarios fulfilling customer's specifications. To estimate residual life under different operating scenarios of an existing runner designed years ago for best efficiency base load operation, Andritz Hydro's design rules and tools would necessarily lead to conservative results. While the geometry of a new runner can be modified to fulfil all conservative mechanical design rules, the predicted fatigue life of an existing runner under off-design operating conditions may appear rather short because of the conservative safety factor included in the calculations. The most precise and reliable way to calculate residual life of an existing runner under different operating scenarios is to perform a strain gauge measurement campaign on the runner. This paper presents the runner strain gage measurement campaign of a mid-head Francis turbine over all the operating conditions available during the test, the analysis of the measurement signals and the runner residual life assessment under different operating scenarios. With these results, the maintenance cost of the change in operating mode can then be calculated and foreseen by the power plant owner.

32 citations

Journal ArticleDOI
TL;DR: In this paper, the authors explore the factors driving the development and diffusion of new renewable energy technologies, and the role geothermal power production could play in the future of the German electricity market.

32 citations

Patent
Jong Hyun Shin1, Young-Jin Park1
07 Dec 2012
TL;DR: In this paper, the authors present a power consumption control method capable of providing a power storage being utilized as an uninterruptible power supply (UPS), and in a case of an emergency, automatically selecting a load to supply a backup power to the load, and performing an emergency mode to immediately finish a current operation of a load if it is determined that an abnormality in the supply of both of the grid power and the renewable power has occurred.
Abstract: A power consumption control apparatus and a power consumption control method capable of providing a power storage being utilized as an uninterruptible power supply (UPS), and in a case of an emergency, automatically selecting a load to supply a backup power to the load, the power consumption control method including determining an occurrence of an abnormality in a supply of a grid power and a renewable power, performing an emergency mode to immediately finish a current operation of a load if it is determined that an abnormality in the supply of both of the grid power and the renewable power has occurred, and performing a standby mode to stand by until the current operation of the load is finished in a normal manner if it is determined that an abnormality in the supply of the grid power has occurred while the supply of the renewable power is normal.

32 citations

Proceedings ArticleDOI
07 Jun 2009
TL;DR: In this paper, the feasibility of implementing a hybrid solar photovoltaic (PV) + combined heat and power (CHP) and battery bank system for a residential application to generate reliable base load power to the grid in Ontario was investigated.
Abstract: This paper investigates the feasibility of implementing a hybrid solar photovoltaic (PV) + combined heat and power (CHP) and battery bank system for a residential application to generate reliable base load power to the grid in Ontario. Deploying PV on a large-scale has a penetration level threshold due to the inherent power supply intermittency associated with the solar resource. By creating a hybrid PV+CHP system there is potential of increasing the PV penetration level. One year of one second resolution pyranometer data is analyzed for Kingston Ontario to determine the total amount of PV energy generation potential, the rate of change of PV power generation due to intermittent cloud cover, and the daily CHP run time required to supply reliable base load power to the grid using this hybrid system. This analysis found that the vast majority of solar energy fluctuations are small in magnitude and the worst case energy fluctuation can be accommodated by relatively inexpensive and simple storage with conventional lead-acid batteries. For systems where the PV power rating is identical to the CHP unit, the CHP unit must run for more than twenty hours a day for the system to meet the base load requirement during the winter months. This provides a fortunate supply of heat, which can be used for the needed home heating. This paper provides analysis for a preliminary base line system.

32 citations


Network Information
Related Topics (5)
Electric power system
133K papers, 1.7M citations
92% related
Wind power
99K papers, 1.5M citations
91% related
Renewable energy
87.6K papers, 1.6M citations
87% related
Energy storage
65.6K papers, 1.1M citations
85% related
Photovoltaic system
103.9K papers, 1.6M citations
83% related
Performance
Metrics
No. of papers in the topic in previous years
YearPapers
202344
202299
202170
202073
201989
2018103