scispace - formally typeset
Search or ask a question
Topic

Imaging phantom

About: Imaging phantom is a research topic. Over the lifetime, 28170 publications have been published within this topic receiving 510003 citations. The topic is also known as: phantom.


Papers
More filters
Journal ArticleDOI
TL;DR: In this article, the thermodynamic properties of a quantum phantom field in a flat Friedmann-Robertson-Walker universe were investigated and the authors derived expressions for the temperature and entropy of a general dark-energy field with equation of state $p=\omega\rho$ from which they deduced that, whereas the temperature of a cosmic phantom fluid is definite negative, its entropy is always positive.

141 citations

Journal ArticleDOI
TL;DR: A diffusion phantom made up of two textile rayon fibre bundles, crossing at 90°, was designed and dedicated to ex vivo q-ball validation on a clinical scanner, validating efficiency of QBI for depicting fibre crossing.
Abstract: Magnetic resonance (MR) diffusion imaging provides a valuable tool used for inferring structural anisotropy of brain white matter connectivity from diffusion tensor imaging. Recently, several high angular resolution diffusion models were introduced in order to overcome the inadequacy of the tensor model for describing fibre crossing within a single voxel. Among them, q-ball imaging (QBI), inherited from the q-space method, relies on a spherical Radon transform providing a direct relationship between the diffusion-weighted MR signal and the orientation distribution function (ODF). Experimental validation of these methods in a model system is necessary to determine the accuracy of the methods and to optimize them. A diffusion phantom made up of two textile rayon fibre (comparable in diameter to axons) bundles, crossing at 90°, was designed and dedicated to ex vivo q-ball validation on a clinical scanner. Normalized ODFs were calculated inside regions of interest corresponding to monomodal and bimodal configurations of underlying structures. Three-dimensional renderings of ODFs revealed monomodal shapes for voxels containing single-fibre population and bimodal patterns for voxels located within the crossing area. Principal orientations were estimated from ODFs and were compared with a priori structural fibre directions, validating efficiency of QBI for depicting fibre crossing. In the homogeneous regions, QBI detected the fibre angle with an accuracy of 19° and in the fibre-crossing region with an accuracy of 30°.

141 citations

Journal ArticleDOI
TL;DR: 3D OFM provided an accurate estimation of intrathoracic tumour motion, with estimated errors less than the voxel dimension in a simulated motion phantom study, and surprisingly, oesophageal tumours motion was large and nonuniform, with greatest motion occurring at the gastro-oesophageaal junction.
Abstract: The purpose of this work was to develop and validate an automated method for intrathoracic tumour motion estimation from breath-hold computed tomography (BH CT) imaging using the three-dimensional optical flow method (3D OFM). A modified 3D OFM algorithm provided 3D displacement vectors for each voxel which were used to map tumour voxels on expiration BH CT onto inspiration BH CT images. A thoracic phantom and simulated expiration/inspiration BH CT pairs were used for validation. The 3D OFM was applied to the measured inspiration and expiration BH CT images from one lung cancer and one oesophageal cancer patient. The resulting displacements were plotted in histogram format and analysed to provide insight regarding the tumour motion. The phantom tumour displacement was measured as 1.20 and 2.40 cm with full-width at tenth maximum (FWTM) for the distribution of displacement estimates of 0.008 and 0.006 cm, respectively. The maximum error of any single voxel's motion estimate was 1.1 mm along the z-dimension or approximately one-third of the z-dimension voxel size. The simulated BH CT pairs revealed an rms error of less than 0.25 mm. The displacement of the oesophageal tumours was nonuniform and up to 1.4 cm, this was a new finding. A lung tumour maximum displacement of 2.4 cm was found in the case evaluated. In conclusion, 3D OFM provided an accurate estimation of intrathoracic tumour motion, with estimated errors less than the voxel dimension in a simulated motion phantom study. Surprisingly, oesophageal tumour motion was large and nonuniform, with greatest motion occurring at the gastro-oesophageal junction.

140 citations

Journal ArticleDOI
TL;DR: This work investigates the in vivo performance of a 400 MHz cryogenic transmit/receive RF probe (CryoProbe) designed for MRI of the mouse brain and concludes that this low temperature detection device represents an attractive option to increase the performance of small animal MR systems operating at 9.4 Tesla.
Abstract: The increasing number of mouse models of human disease used in biomedical research applications has led to an enhanced interest in non-invasive imaging of mice, e.g. using MRI for phenotyping. However, MRI of small rodents puts high demands on the sensitivity of data acquisition. This requirement can be addressed by using cryogenic radio-frequency (RF) detection devices. The aim of this work was to investigate the in vivo performance of a 400 MHz cryogenic transmit/receive RF probe (CryoProbe) designed for MRI of the mouse brain. To characterize this novel probe, MR data sets were acquired with both the CryoProbe and a matched conventional receive-only surface coil operating at room temperature (RT) using conventional acquisition protocols (gradient and spin echo) with identical parameter settings. Quantitative comparisons in phantom and in vivo experiments revealed gains in the signal-to-noise ratio (SNR) of 2.4 and 2.5, respectively. The increased sensitivity of the CryoProbe was invested to enhance the image quality of high resolution structural images acquired in scan times compatible with routine operation (< 45 min). In high resolution (30 x 30 x 300 mu m(3)) structural images of the mouse cerebellum, anatomical details such as Purkinje cell and molecular layers could be identified. Similarly, isotropic (60 x 60 x 60 mu m(3)) imaging of mouse cortical and subcortical areas revealed anatomical structures smaller than 100 mu m. Finally, 3D MR angiography (52 x 80 x 80 mu m) of the brain vasculature enabled the detailed reconstruction of intracranial vessels (anterior and middle cerebral artery). In conclusion, this low temperature detection device represents an attractive option to increase the performance of small animal MR systems operating at 9.4 Tesla. Copyright (C) 2009 John Wiley & Sons, Ltd.

140 citations

Journal ArticleDOI
TL;DR: An integration of dynamic light scattering (DLS) and optical coherence tomography (OCT) for high-resolution 3D imaging of heterogeneous diffusion and flow is introduced and a fitting algorithm is developed to estimate dynamic parameters including the axial and transverse velocities and the diffusion coefficient.
Abstract: We introduce an integration of dynamic light scattering (DLS) and optical coherence tomography (OCT) for high-resolution 3D imaging of heterogeneous diffusion and flow. DLS analyzes fluctuations in light scattered by particles to measure diffusion or flow of the particles, and OCT uses coherence gating to collect light only scattered from a small volume for high-resolution structural imaging. Therefore, the integration of DLS and OCT enables high-resolution 3D imaging of diffusion and flow. We derived a theory under the assumption that static and moving particles are mixed within the OCT resolution volume and the moving particles can exhibit either diffusive or translational motion. Based on this theory, we developed a fitting algorithm to estimate dynamic parameters including the axial and transverse velocities and the diffusion coefficient. We validated DLS-OCT measurements of diffusion and flow through numerical simulations and phantom experiments. As an example application, we performed DLS-OCT imaging of the living animal brain, resulting in 3D maps of the absolute and axial velocities, the diffusion coefficient, and the coefficient of determination.

140 citations


Network Information
Related Topics (5)
Iterative reconstruction
41.2K papers, 841.1K citations
89% related
Image quality
52.7K papers, 787.9K citations
88% related
Positron emission tomography
19.9K papers, 555.2K citations
82% related
Image resolution
38.7K papers, 736.5K citations
82% related
Detector
146.5K papers, 1.3M citations
81% related
Performance
Metrics
No. of papers in the topic in previous years
YearPapers
20231,623
20223,476
20211,221
20201,482
20191,568
20181,503