scispace - formally typeset
Search or ask a question
Topic

Intra-rater reliability

About: Intra-rater reliability is a research topic. Over the lifetime, 2073 publications have been published within this topic receiving 140968 citations.


Papers
More filters
Book
28 Sep 2011
TL;DR: This chapter discusses the construction of Reliability Engineering tools, which addressed the challenge of estimating the failure characteristics of the physical Reliability Requirements.
Abstract: 1: Principal Concepts. 2: Tools. 3: Phenomena, Events, and Relations. 4: Structure. 5: Load. 6: Environment. 7: Physical Reliability Requirements. 8: Probabilistic and Statistical Reliability Requirements. 9: Calculation of the Failure Characteristics. 10: Reliability Parameters. 11: Probability-Based Optimization. 12: Direct Method. 13: Method of Extreme Functions. 14: Method of Extreme Values. 15: Reliability Engineering. 16: The Future. Index.

24 citations

Journal ArticleDOI
TL;DR: The test for shoulder muscle strength using elastic resistance bands has excellent validity and reliability, but produces systematically lower torque values than MVC, who has an initial concentric phase and is performed bilaterally and standing upright.
Abstract: Valid and reliable measurements of muscle strength are important in sport medicine. This study assesses concurrent validity and intrarater reliability (test-retest reliability) of elastic resistance bands for measuring shoulder muscle strength. Altogether, 50 healthy adults [mean age 36.0 (SD: 11.6), 29 women and 21 men] participated in testing and retesting 1-2 weeks later. The maximal elastic resistance (TheraBand) that each participant could hold for 3 s during standing bilateral shoulder abduction to 90° was converted into torque and validated against gold standard maximal voluntary isometric contraction (MVC) (Vishay force transducer) performed unilaterally while lying supine. The intrarater reliability of both tests were high; for the MVC and elastic band test, respectively, ICC(3,1) was 0.98 (95% CI: 0.97-0.99) and 0.99 (95% CI: 0.98-1.00), and measurement error was 4.8% (95% CI: 3.7-5.9) and 4.7% (95% CI: 3.1-6.2). For concurrent validity, ICC(3,1) was 0.96 (95% CI: 0.95-0.98) and measurement error was 8.1% (95% CI: 6.6-9.6), and the elastic band test explained 93% of the variance in the MVC test. However, the elastic band test produced systematically lower torque values than the MVC [56.5 (SD: 26.8) vs 66.5 (SD: 25.5) Nm, P < 0.01]. In conclusion, the test for shoulder muscle strength using elastic resistance bands has excellent validity and reliability, but produces systematically lower torque values than MVC. The reason for the lower torque values may be that the elastic band test has an initial concentric phase and is performed bilaterally and standing upright.

24 citations

Journal ArticleDOI
TL;DR: With the ease of use, portability, and ability to record multiple measurements without stopping, these devices can be applied to clinical and research settings and show moderate to excellent concurrent validity.
Abstract: Kubas, C, Chen, Y-W, Echeverri, S, McCann, S, Denhoed, M, Walker, C, Kennedy, C, and Reid, WD. Reliability and validity of cervical range of motion and muscle strength testing. J Strength Cond Res 31(4): 1087-1096, 2017-Cervical range of motion (ROM) and strength are fundamental measures to assess treatment effectiveness. The JTECH wireless devices provide versatile means of quantifying these measurements. The purpose of this study was to determine intrarater and interrater reliabilities and concurrent validity of the JTECH wireless dual inclinometer and handheld dynamometer. This study included 20 healthy subjects (mean age = 28.7 ± 7.8 years). The directions of ROM movement measured were cervical flexion, extension, lateral flexion, and rotation. Isometric strength was measured for flexion, extension, and lateral flexion. Two testers measured cervical ROM and isometric strength for each subject using the JTECH devices during 2 or 3 sessions to determine reliability. The same ROM and muscle strength movements were measured using the CROM3 and MicroFET2, respectively, to assess concurrent validity. Reliability and validity were analyzed using intraclass correlation coefficient (ICC), along with SEM and minimal detectable change. The results of this study showed that the intrarater reliability of the JTECH inclinometer and dynamometer was moderate to excellent (ICCs (3,1) = 0.53-0.90 and 0.74-0.91, respectively). The interrater reliability of the JTECH inclinometer was moderate to excellent (ICCs (2,3) = 0.69-0.89), whereas the JTECH dynamometer showed excellent interrater reliability (ICCs (2,3) = 0.84-0.88). The JTECH inclinometer and dynamometer showed moderate to excellent concurrent validity (ICCs (3,2) = 0.65-0.91 and 0.91-0.96, respectively). With the ease of use, portability, and ability to record multiple measurements without stopping, these devices can be applied to clinical and research settings.

23 citations

Book
06 Jun 2017
TL;DR: Book file that related with probabilistic_physics_of_failure_approach_to_reliability_modeling_accelera ted_testing_prognosis_and-reliability-assessment_performability_engineerin g_series_reliable_evaluation_of-engineering-systems-concepts-and-techni-ques book.
Abstract: [Read Online] Probabilistic_physics_of_failure_approach_to_reliability_modeling_accelera ted_testing_prognosis_and_reliability_assessment_performability_engineerin g_series_reliability_evaluation_of_engineering_systems_concepts_and_techni ques [PDF] [EPUB] Download or Read online all PDF Book file that related with probabilistic_physics_of_failure_approach_to_reliability_modeling_accelera ted_testing_prognosis_and_reliability_assessment_performability_engineerin g_series_reliability_evaluation_of_engineering_systems_concepts_and_techni ques book. *FREE* Shipping Probabilistic_physics_of_failure_approach_to_reliability_modeling_accelera ted_testing_prognosis_and_reliability_assessment_performability_engineerin g_series_reliability_evaluation_of_engineering_systems_concepts_and_techni ques PDF Book for everyone.

23 citations

Journal ArticleDOI
TL;DR: The Baseline hydraulic dynamometer with a more functional doorknob handle had good intra- and interrater reliability and demonstrated moderate validity compared with Cybex 6000 strength testing.
Abstract: OBJECTIVE. The objective was to determine the reliability of a portable forearm strength hydraulic dynamometer with a doorknob handle and assess its validity compared with a Cybex 6000 (Cybex International, Inc., Medway, MA) isometric torque assessment. METHOD. Eighteen volunteers (with a total of 30 forearms) participated in this one-session methodological study to determine the intra- and interrater reliability and criterion validity of a forearm dynamometer. RESULTS. Intrarater reliability for both assessors for pronation was (intraclass correlation coefficient [ICC]3,1 = .937�.961) and for supination was (ICC3,1 = .923�.968). Interrater reliability for pronation was ICC3,2 = .927 and for supination was ICC3,2 = .847. Criterion validity of the Baseline hydraulic dynamometer (Fabrication Enterprises Inc., White Plains, NY) compared with the Cybex 6000 was .574�.664 for pronation and .749�.750 for supination. CONCLUSION. The Baseline hydraulic dynamometer with a more functional doorknob handle had good intra- and interrater reliability and demonstrated moderate validity compared with Cybex 6000 strength testing

23 citations


Network Information
Related Topics (5)
Rehabilitation
46.2K papers, 776.3K citations
69% related
Ankle
30.4K papers, 687.4K citations
68% related
Systematic review
33.3K papers, 1.6M citations
68% related
Activities of daily living
18.2K papers, 592.8K citations
68% related
Validity
13.8K papers, 776K citations
67% related
Performance
Metrics
No. of papers in the topic in previous years
YearPapers
202342
202278
202186
202083
201986
201867