scispace - formally typeset
Search or ask a question
Topic

Intra-rater reliability

About: Intra-rater reliability is a research topic. Over the lifetime, 2073 publications have been published within this topic receiving 140968 citations.


Papers
More filters
Journal ArticleDOI
TL;DR: Ananalysis of the relative contribution of different diabetes control indices to the diabetologists' judgments indicated that HbA1 influenced raters' judgments at both institutions more than any other single variable.
Abstract: In study 1, laboratory and supervised blood or urine test data from actual cases were used to develop patient profiles. Seven diabetologists from the same institution rated the diabetic control of 125 profiles on a four-point scale (1 = poor, 2 = fair, 3 = good, 4 = excellent). Six of the 7 diabetologists demonstrated adequate intra- and interrater reliability. Study 2 assessed the reliability of judgments of diabetic control made by diabetologists working in two different settings. There were 9 raters from institution 1 and8 from institution 2. The impact of the amount and type of information on judgment reliability was evaluated by developing two types of profiles. The test form contained only laboratory and supervised blood or urine test data similar to that utilized in study 1. The history form contained this information as well as other descriptive data typically available to diabetologists. The 17 diabetologists rated 125 anonymous profiles on each of twoseparate occasions ∼ 1 wk apart. On one occasion they rated profiles presented on the test form. On the other occasion they rated profiles presented on the history form. As in study 1, the diabetologist raters demonstrated adequate intra- and interrater reliability. Intrarater reliability was somewhat better when rating test form profiles compared with history form profiles. Reliability was not higher within than between institutions. Ananalysis of the relative contribution of different diabetes control indices to the diabetologists' judgments indicated that HbA1 influenced raters' judgmentsat both institutions more than any other single variable. However, raters utilized other information as well, particularly the urine test and fasting blood glucose results. Use of a cholesterol measure by institution 2 raters, but not by institution 1 raters, was theonly clearly discrepant use of test form data by the diabetologists working in two different settings. A mathematical prediction equation was developed that accurately simulated the diabetologists' judgments. The robustness of this equation was tested and demonstrated on a cross-validation sample of the cases utilized in study 1.

5 citations

Journal Article

5 citations

Journal Article
TL;DR: The TRE test using a portable digital inclinometer demonstrated good to excellent reliability and may be a cost effective clinical measurement for trunk reposition sense measurement.
Abstract: 【Purpose: A cost effective tool for the clinical measurement of trunk reposition sense is clearly needed. This study was to analyze intrarater and interrater Reliability of trunk repositioning error (TRE) test which assesses trunk position sense using a portable digital inclinometer. Methods: Twenty four normal healthy subjects were recruited. TRE was measured using a portable digital inclinometer. A digital inclinometer (Acumar-ACU360; Lafayetter Instrument) with precision to $1^{\circ}$ was placed on skin over the spinous process from first to second thoracic vertebra (T1-T2) and secured with double-sided tape. TRE test during sitting forward and lateral flexion movement was assessed. When they reached a point approximately 50% of full trunk flexion range, the examiner instructed the subjects to stop and told them. This was the target position that they should try to reproduce exactly. Each subject performed six trials. Results: ICC (2,1) for intrarater reliability (with-day and between-day) of TRE test in sagittal and frontal plane of movement was 0.75 and 0.78 (excellent reliability). Interrater reliability was 0.66 in sagittal and 0.64, frontal plane (fair to good reliability). However, there were poor correlations between an average of TRE test in sagittal and frontal plane. Conclusion: TRE test using a portable digital inclinometer demonstrated good to excellent reliability. The device may be a cost effective clinical measurement for trunk reposition sense measurement.】

5 citations

Journal ArticleDOI
TL;DR: Measurements of LAM elasticity are reliable in patients with AIS and the images extracted from SWE can successfully be used to assess LAM thicknesses with high reliability.

5 citations


Network Information
Related Topics (5)
Rehabilitation
46.2K papers, 776.3K citations
69% related
Ankle
30.4K papers, 687.4K citations
68% related
Systematic review
33.3K papers, 1.6M citations
68% related
Activities of daily living
18.2K papers, 592.8K citations
68% related
Validity
13.8K papers, 776K citations
67% related
Performance
Metrics
No. of papers in the topic in previous years
YearPapers
202342
202278
202186
202083
201986
201867