Journal ArticleDOI
TL;DR: Several system issues which may be encountered as DR penetrates into distribution systems are discussed, including vulnerability and overvoltages due to islanding and coordination with reclosing, system restoration and network issues.
Abstract: Because traditional electric power distribution systems have been designed assuming the primary substation is the sole source of power and short-circuit capacity, DR interconnection results in operating situations that do not occur in a conventional system. This paper discusses several system issues which may be encountered as DR penetrates into distribution systems. The voltage issues covered are the DR impact on system voltage, interaction of DR and capacitor operations, and interaction of DR and voltage regulator and LTC operations. Protection issues include fuse coordination, feeding faults after utility protection opens, impact of DR on interrupting rating of devices, faults on adjacent feeders, fault detection, ground source impacts, single phase interruption on three phase line, recloser coordination and conductor burndown. Loss of power grid is also discussed, including vulnerability and overvoltages due to islanding and coordination with reclosing. Also covered separately are system restoration and network issues.

939 citations

Journal ArticleDOI
TL;DR: The paper explorers the resistive output impedance of the parallel-connected inverters in an island microgrid and proposes a novel wireless load-sharing controller for islanding parallel invertes in an ac distributed system.
Abstract: In this paper, a novel wireless load-sharing controller for islanding parallel inverters in an ac-distributed system is proposed This paper explores the resistive output impedance of the parallel-connected inverters in an island microgrid The control loops are devised and analyzed, taking into account the special nature of a low-voltage microgrid, in which the line impedance is mainly resistive and the distance between the inverters makes the control intercommunication between them difficult In contrast with the conventional droop-control method, the proposed controller uses resistive output impedance, and as a result, a different control law is obtained The controller is implemented by using a digital signal processor board, which only uses local measurements of the unit, thus increasing the modularity, reliability, and flexibility of the distributed system Experimental results are provided from two 6-kVA inverters connected in parallel, showing the features of the proposed wireless control

928 citations

Journal ArticleDOI
TL;DR: In this paper, the importance of grid-connected PV system regarding the intermittent nature of renewable generation, and the characterization of PV generation with regard to grid code compliance is investigated and emphasized.
Abstract: Traditional electric power systems are designed in large part to utilize large baseload power plants, with limited ability to rapidly ramp output or reduce output below a certain level. The increase in demand variability created by intermittent sources such as photovoltaic (PV) presents new challenges to increase system flexibility. This paper aims to investigate and emphasize the importance of the grid-connected PV system regarding the intermittent nature of renewable generation, and the characterization of PV generation with regard to grid code compliance. The investigation was conducted to critically review the literature on expected potential problems associated with high penetration levels and islanding prevention methods of grid tied PV. According to the survey, PV grid connection inverters have fairly good performance. They have high conversion efficiency and power factor exceeding 90% for wide operating range, while maintaining current harmonics THD less than 5%. Numerous large-scale projects are currently being commissioned, with more planned for the near future. Prices of both PV and balance of system components (BOS) are decreasing which will lead to further increase in use. The technical requirements from the utility power system side need to be satisfied to ensure the safety of the PV installer and the reliability of the utility grid. Identifying the technical requirements for grid interconnection and solving the interconnect problems such as islanding detection, harmonic distortion requirements and electromagnetic interference are therefore very important issues for widespread application of PV systems. The control circuit also provides sufficient control and protection functions like maximum power tracking, inverter current control and power factor control. Reliability, life span and maintenance needs should be certified through the long-term operation of PV system. Further reduction of cost, size and weight is required for more utilization of PV systems. Using PV inverters with a variable power factor at high penetration levels may increase the number of balanced conditions and subsequently increase the probability of islanding. It is strongly recommended that PV inverters should be operated at unity power factor.

923 citations

Journal ArticleDOI
TL;DR: In this paper, a detailed account of analytical work carried out to determine the parameters of power system stabilizers (PSS) for the Darlington nuclear generating station presently under construction in eastern Ontario is presented.
Abstract: This paper provides a detailed account of analytical work carried out to determine the parameters of power system stabilizers (PSS) for the Darlington nuclear generating station presently under construction in eastern Ontario. The results presented are, however, of general interest and provide a comprehensive analysis of the effects of the different stabilizer parameters on the overall dynamic performance of the power system. They show how stabilizer settings may be selected so as to enhance the steady-state and transient stability of local plant modes as well as inter-area modes in large interconnected systems. In addition, it is shown that the selected parameters result in satisfactory performance during system islanding conditions, when large frequency excursions are experienced. Darlington GS, when completed by 1992, will comprise four 1100 MVA, 0.85 p.f., 1800 RPM turbine generators with "CANDU-PHW" reactors, moderated and cooled by heavy water. The station will be incorporated into the 500 kV network through three double-circuit lines. The units will be equipped with transformer-fed thyristor excitation systems and Delta-P-Omega type PSS [1, 2].

854 citations

Journal ArticleDOI
TL;DR: This paper reviews and categorizes various approaches of power sharing control principles, and compares in terms of their respective advantages and disadvantages.
Abstract: Microgrid is a new concept for future energy distribution system that enables renewable energy integration. It generally consists of multiple distributed generators that are usually interfaced to the grid through power inverters. For the islanding operation of ac microgrids, two important tasks are to share the load demand among multiple parallel connected inverters proportionately, and maintain the voltage and frequency stabilities. This paper reviews and categorizes various approaches of power sharing control principles. Simultaneously, the control schemes are graphically illustrated. Moreover, various control approaches are compared in terms of their respective advantages and disadvantages. Finally, this paper presents the future trends.

751 citations


Network Information
Related Topics (5)
Electric power system
133K papers, 1.7M citations
93% related
Wind power
99K papers, 1.5M citations
88% related
Photovoltaic system
103.9K papers, 1.6M citations
86% related
Voltage
296.3K papers, 1.7M citations
85% related
Fault (power engineering)
119.7K papers, 981.6K citations
84% related
Performance
Metrics
No. of papers in the topic in previous years
YearPapers
2023190
2022408
2021334
2020401
2019430
2018462