scispace - formally typeset
Search or ask a question
Topic

Momentum

About: Momentum is a research topic. Over the lifetime, 19070 publications have been published within this topic receiving 367167 citations. The topic is also known as: linear momentum & translational momentum.


Papers
More filters
Journal ArticleDOI
TL;DR: In this paper, a model for studying ocean circulation problems taking into account the complicated outline and bottom topography of the World Ocean is presented, and the model is designed to be as consistent as possible with the continuous equations with respect to energy.

1,048 citations

Journal ArticleDOI
TL;DR: This work demonstrates a 32-Gbit’s−1 millimetre-wave link over 2.5 metres with a spectral efficiency of ~16 bit s− 1 Hz−1 using four independent orbital–angular momentum beams on each of two polarizations, and shows an 8-Gbits−1 link containing two orbital angular momentum beams with crosstalk less than −12.5 dB.
Abstract: One property of electromagnetic waves that has been recently explored is the ability to multiplex multiple beams, such that each beam has a unique helical phase front. The amount of phase front ‘twisting’ indicates the orbital angular momentum state number, and beams with different orbital angular momentum are orthogonal. Such orbital angular momentum based multiplexing can potentially increase the system capacity and spectral efficiency of millimetre-wave wireless communication links with a single aperture pair by transmitting multiple coaxial data streams. Here we demonstrate a 32-Gbit s−1 millimetre-wave link over 2.5 metres with a spectral efficiency of ~16 bit s−1 Hz−1 using four independent orbital–angular momentum beams on each of two polarizations. All eight orbital angular momentum channels are recovered with bit-error rates below 3.8 × 10−3. In addition, we demonstrate a millimetre-wave orbital angular momentum mode demultiplexer to demultiplex four orbital angular momentum channels with crosstalk less than −12.5 dB and show an 8-Gbit s−1 link containing two orbital angular momentum beams on each of two polarizations. High speed data transmission using orbital angular momentum beams has been recently demonstrated. Here, Yan et al. demonstrate a 32 Gbit/s millimetre-wave communication link using eight coaxially propagating independent orbital angular momentum beams with four orbital angular momentum states on two orthogonal polarizations.

1,002 citations

Journal ArticleDOI
TL;DR: The cold target recoil ion momentum spectroscopy (COLTRIMS) is a momentum space imaging technique for the investigation of the dynamics of ionizing ion, electron or photon impact reactions with atoms or molecules as mentioned in this paper.

985 citations

Journal ArticleDOI
TL;DR: In this paper, the conservation properties of the mass, momentum, and kinetic energy equations for incompressible flow are specified as analytical requirements for a proper set of discrete equations, and finite difference schemes for regular and staggered grid systems are checked for violations of the conservation requirements and a few important discrepancies are pointed out.

978 citations

Journal ArticleDOI
TL;DR: In this paper, the authors considered a new type of quantum nondemolition measurement called back-action-evading measurement, where the real part of the harmonic oscillator's complex amplitude is measured by a single transducer.
Abstract: The monitoring of a quantum-mechanical harmonic oscillator on which a classical force acts is important in a variety of high-precision experiments, such as the attempt to detect gravitational radiation. This paper reviews the standard techniques for monitoring the oscillator, and introduces a new technique which, in principle, can determine the details of the force with arbitrary accuracy, despite the quantum properties of the oscillator. The standard method for monitoring the oscillator is the "amplitude-and-phase" method (position or momentum transducer with output fed through a narrow-band amplifier). The accuracy obtainable by this method is limited by the uncertainty principle ("standard quantum limit"). To do better requires a measurement of the type which Braginsky has called "quantum nondemolition." A well known quantum nondemolition technique is "quantum counting," which can detect an arbitrarily weak classical force, but which cannot provide good accuracy in determining its precise time dependence. This paper considers extensively a new type of quantum nondemolition measurement—a "back-action-evading" measurement of the real part X_1 (or the imaginary part X_2) of the oscillator's complex amplitude. In principle X_1 can be measured "arbitrarily quickly and arbitrarily accurately," and a sequence of such measurements can lead to an arbitrarily accurate monitoring of the classical force. The authors describe explicit Gedanken experiments which demonstrate that X_1 can be measured arbitrarily quickly and arbitrarily accurately. In these experiments the measuring apparatus must be coupled to both the position (position transducer) and the momentum (momentum transducer) of the oscillator, and both couplings must be modulated sinusoidally. For a given measurement time the strength of the coupling determines the accuracy of the measurement; for arbitrarily strong coupling the measurement can be arbitrarily accurate. The "momentum transducer" is constructed by combining a "velocity transducer" with a "negative capacitor" or "negative spring." The modulated couplings are provided by an external, classical generator, which can be realized as a harmonic oscillator excited in an arbitrarily energetic, coherent state. One can avoid the use of two transducers by making "stroboscopic measurements" of X_1, in which one measures position (or momentum) at half-cycle intervals. Alternatively, one can make "continuous single-transducer" measurements of X_1 by modulating appropriately the output of a single transducer (position or momentum), and then filtering the output to pick out the information about X_1 and reject information about X_2. Continuous single-transducer measurements are useful in the case of weak coupling. In this case long measurement times are required to achieve good accuracy, and continuous single-transducer measurements are almost as good as perfectly coupled two-transducer measurements. Finally, the authors develop a theory of quantum nondemolition measurement for arbitrary systems. This paper (Paper I) concentrates on issues of principle; a sequel (Paper II) will consider issues of practice.

969 citations


Network Information
Related Topics (5)
Scattering
152.3K papers, 3M citations
87% related
Particle
96.5K papers, 1.9M citations
86% related
Magnetic field
167.5K papers, 2.3M citations
84% related
Ground state
70K papers, 1.5M citations
84% related
Turbulence
112.1K papers, 2.7M citations
84% related
Performance
Metrics
No. of papers in the topic in previous years
YearPapers
202214
2021886
2020709
2019705
2018647
2017709