scispace - formally typeset
Search or ask a question
Topic

Night vision

About: Night vision is a research topic. Over the lifetime, 6004 publications have been published within this topic receiving 67372 citations.


Papers
More filters
Patent
09 Sep 1994
TL;DR: In this paper, a flip-up helmet mount for a night vision goggle includes a plurality of nested movable brackets (18, 72, 100), the first bracket is secured to a user's helmet and the second bracket pivots relative to the first to provide flipup motion for the goggle (12), and the third bracket (100) is pivotal to provide a tilt angle adjustment for the night vision viewer (140).
Abstract: A flip-up helmet mount (16) for a night vision goggle (12) includes a plurality of nested movable brackets (18, 72, 100), the first bracket (18) is secured to a user's helmet (14). The second bracket (72) pivots relative to the first to provide flip-up motion for the goggle (12), and the third bracket (100) is pivotal on the second bracket (72) to provide a tilt angle adjustment for the night vision viewer (140). In order to both save battery power, and prevent the user from inadvertently revealing his position, the support structure includes a magnetic flux switch that maintains the viewer (140) on only when the viewer (140) is in its use position.

89 citations

Proceedings ArticleDOI
09 Jun 2003
TL;DR: The paper investigates the possibilities of reusing available features for visible images by analyzing the different properties of infrared images and visible images and proposes the following novel features: special projection feature for segmentation, and two-axis pixel-distribution feature for classification.
Abstract: In order to improve the safety of night driving, automatic pedestrian detection has received more and more attraction. Since reliability is the most important issue in these systems, multi-dimensional-feature-based segmentation and classification needs to be introduced, and each axis should be efficient and be as much independent (to each other) as possible. To choose effective multi-dimensional features for infrared-image-based detection, the paper first investigates the possibilities of reusing available features for visible images by analyzing the different properties of infrared images and visible images. To take advantage of unique properties of infrared images, we propose the following novel features: special projection feature for segmentation, and two-axis pixel-distribution feature for classification. The segmentation based on new features does not depend on many assumptions and is shape-independent, thus avoiding brute-force multiple templates and multi-scale pyramid searching. The novel classification features include histogram feature and inertial feature that are independent and complimentary, thus the two-dimensional fusion-based classification significantly improves detection accuracy. These proposed features are independent from conventional pixel-array feature, and can be further fused with other general pedestrian detection features to improve simplicity, speed, and reliability.

88 citations

Patent
11 Mar 1992
TL;DR: In this paper, a backlight system for liquid crystal device display is equipped with a dual lighting system for day viewing and compatible with night vision systems, the day lighting system uses conventional fluorescent or incandescent lamps for full color display during daytime use and the night lighting system is either filtered to remove infrared and near infrared wavelengths or which is chosen from a class of sources which does not emit such wavelengths.
Abstract: A backlight system for liquid crystal device display is equipped with a dual lighting system for day viewing and compatible with night vision systems. The day lighting system uses conventional fluorescent or incandescent lamps for full color display during daytime use. The night lighting system uses a light source which is either filtered to remove infrared and near infrared wavelengths or which is chosen from a class of sources which does not emit such wavelengths. The day lighting system is disabled while the night system is in use.

88 citations

Journal ArticleDOI
TL;DR: The evidence that DNA replication is discontinuous during the cycle, occurring within the distinct time interval during the interphase, was obtained by autoradiography, and provided the foundation for subdivision of the cell cycle into four major phases.
Abstract: PREHISTORY: THE PAINS OF THE PRE–FLOW CYTOMETRY ERA For young investigators who presently enter their scientific pursuit focused on cell cycle and have flow cytometry (FCM) at their disposal, it may be difficult to visualize the hardship of experimental procedures during the precytometry era. Autoradiography (1) was then the predominant method for cell cycle studies. It was a cumbersome and time-consuming methodology. The radioisotope-labeled cells deposited on microscope slides had to be fixed and covered with photographic emulsion in nearly total darkness. This was particularly tricky when using the “stripping film” approach, and required the preparer to either be on a carrot diet or to consume large quantities of vitamin A to enhance his or her night vision. After careful air-drying, the autoradiographs had to be left in light-proof boxes for several days’ and sometimes weeks’ exposure. Then, again in the dark, the autoradiographs had to be processed through developer, rinse, and fixer, followed by drying. Subsequently, the cells had to be counterstained through the emulsion (which also was tricky, because the emulsion had a tendency to detach, ruining the specimen) and mounted under a coverslip. Quantitative analysis of autoradiographs was painful as well. One had to identify labeled cells located below the silver grains of emulsion by microscopy, and score by eye the labeling index (LI) by counting hundreds of cells per each sample. Sometimes it was necessary to count individual silver grains, to estimate the intensity of cell labeling. Such analysis could take a long time, leaving the investigator with painful eyes and phantom images of the silver grains residing in his or her retina for hours. Attempts to develop semiautomatic or automatic screening of autoradiographs based on backward light scattering by silver grains of emulsion were generally unsuccessful (1). Despite the hardship, important discoveries were made, and numerous autoradiographic techniques, designed to assess the cell cycle and kinetics of cell proliferation, were developed. In fact, the evidence that DNA replication is discontinuous during the cycle, occurring within the distinct time interval during the interphase, was obtained by autoradiography (2,3). It was observed that the radioisotope (P or H)-labeled DNA precursor thymidine was incorporated into nuclei by a fraction of the interphase cells only, leaving many cells with unlabeled nuclei. This finding provided the foundation for subdivision of the cell cycle into four major phases: preDNA synthetic interphase or postmitotic gap (G1), DNA synthesis phase (S), postsynthetic interphase or premitotic gap (G2), and mitosis (M). Perhaps the most elegant technique to measure kinetics of cell progression through the cycle was based on pulse-labeling cells with H-thymidine, followed by analysis of the percentage of labeled mitotic cells (3,4). Analysis of the kinetics of progression of the cohort of cells labeled during the short pulse in S phase through the narrow time-window of the M phase provided an accurate estimate of the duration of each phase of the cycle and of the whole cell cycle (Tc) (4). In vitro and in vivo applications of H-thymidine autoradiography yielded a wealth of information about cell cycle and the kinetics of cell proliferation of several normal and cancer cell models (4–6). Microspectrophotometry and microfluorometry were also applied in studies of the cell cycle, as techniques complementary to autoradiography. They were used to measure the content of DNA, RNA, and protein in individual cells. However, only few laboratories could afford such instruments, which were then generally homemade. Their development and maintenance required a significant investment and close collaboration of biologists with optical and mechanic engineers. During 1967–1968, one of us (ZD) had an opportunity to use these instruments at the Institute for Medical Cell Research and Genetics at the Karolinska Institute in Stockholm. Directed by Torbjorn Caspersson, the “grandfather” of cytometry (7), this laboratory had the most advanced microspectrophotometers and microfluorometers at the time, and was the Mecca for scientists from all over the world who were seeking a possibility to quantify DNA, RNA, or total protein in individual cells. Reservations to use the microspectrophotometer had to be made weeks ahead, as there was a long waiting line of investigators eager to measure cells. After some experience was gained, approximately 40 cells could be measured per hour. This number was then considered be adequate for statistical analyses in most publications. Needless to say, the cell analysis had to be biased

87 citations

Patent
01 Oct 1990
TL;DR: In this paper, a beam of coherent energy is used to illuminate a target with a beam-of-consistency (BE) beamforming device, which is employed with a night-vision system to make available additional energy which can be utilized by an image intensifier in the night vision system in producing a visual image of a target acquired by the system.
Abstract: Devices for illuminating a target with a beam of coherent energy. The device has a number of applications. In one, it is employed with a night vision system to make available additional energy which can be utilized by an image intensifier in the night vision system in producing a visual image of a target acquired by the night vision system.

86 citations


Network Information
Related Topics (5)
Lens (optics)
156.4K papers, 1.2M citations
77% related
Laser
353.1K papers, 4.3M citations
68% related
Retina
28K papers, 1.2M citations
67% related
Visual acuity
32K papers, 797.1K citations
67% related
Glaucoma
31.5K papers, 738.2K citations
66% related
Performance
Metrics
No. of papers in the topic in previous years
YearPapers
202311
202244
2021132
2020170
2019256
2018272