TL;DR: The postoperative IS/OS junction may play an important role in visual recovery after macular hole surgery and SD-OCT is useful for quantitatively measuring IS/ OS junction defects.
Abstract: Background To evaluate the ability of spectral-domain optical coherence tomography (SD-OCT) images of the inner/outer segment (IS/OS) junction to predict macular hole surgery outcomes.

143 citations

Journal ArticleDOI
TL;DR: This work describes a technique, based on interference signal demodulation at multiple frequencies, to extend the physiological relevance of CDOCT by increasing the dynamic range of measurable velocities to hundreds of millimeters per second.
Abstract: Color Doppler optical coherence tomography (CDOCT) is capable of precise velocity mapping in turbid media. Previous CDOCT systems based on the short-time Fourier transform have been limited to maximum flow velocities of the order of tens of millimeters per second. We describe a technique, based on interference signal demodulation at multiple frequencies, to extend the physiological relevance of CDOCT by increasing the dynamic range of measurable velocities to hundreds of millimeters per second. The physiologically important parameter of shear rate is also derived from CDOCT measurements. The measured flow-velocity profiles and shear-rate distributions correlate very well with theoretical predictions. The multiple demodulation technique, therefore, may be useful to monitor blood flow in vivo and to identify regions with high and low shear rates.

143 citations

Journal ArticleDOI
TL;DR: The quantitative evaluation of RKT performance showed that in terms of average contrast-to-noise ratio, there is a significant improvement in image quality between original and enhanced images.
Abstract: During the last few years, optical coherence tomography (OCT) has demonstrated considerable promise as a method of high-resolution intravascular imaging. The goal of this study was to apply and to test the applicability of the rotating kernel transformation (RKT) technique to the speckle reduction and enhancement of OCT images. The technique is locally adaptive. It is based on sequential application of directional masks and selection of the maximum of all outputs. This method enhances the image features by emphasizing thin edges while suppressing a noisy background. Qualitatively, the RKT algorithm provides noticeable improvement over the original image. All processed images are smoother and have better-defined borders of media, intima, and plaque. The quantitative evaluation of RKT performance showed that in terms of average contrast-to-noise ratio, there is a significant improvement in image quality between original and enhanced images. The RKT image enhancement technique shows great promise in improving OCT images for superior boundary identification.

143 citations

Journal ArticleDOI
01 May 2011-Burns
TL;DR: A review of optical modalities currently in clinical use and under development to assist burn surgeons in assessing burn wound severity, including conventional histology/light microscopy, laser Doppler imaging, indocyanine green videoangiography, near-infrared spectroscopy and spectral imaging, and in vivo capillary microscopy are presented.

143 citations

Journal ArticleDOI
TL;DR: A summary of the functional differences between time-domain, spectral-domain and full-field optical coherence tomography, a presentation of specific methods for processing the data acquired by these systems, an introduction to the noise sources that plague the detected signal and the progress made in optical coherent tomography catheter technology over the last decade are provided.
Abstract: The advances made in the last two decades in interference technologies, optical instrumentation, catheter technology, optical detectors, speed of data acquisition and processing as well as light sources have facilitated the transformation of optical coherence tomography from an optical method used mainly in research laboratories into a valuable tool applied in various areas of medicine and health sciences. This review paper highlights the place occupied by optical coherence tomography in relation to other imaging methods that are used in medical and life science areas such as ophthalmology, cardiology, dentistry and gastrointestinal endoscopy. Together with the basic principles that lay behind the imaging method itself, this review provides a summary of the functional differences between time-domain, spectral-domain and full-field optical coherence tomography, a presentation of specific methods for processing the data acquired by these systems, an introduction to the noise sources that plague the detected signal and the progress made in optical coherence tomography catheter technology over the last decade.

143 citations


Network Information
Related Topics (5)
Retinal
24.4K papers, 718.9K citations
85% related
Lens (optics)
156.4K papers, 1.2M citations
83% related
Glaucoma
31.5K papers, 738.2K citations
82% related
Visual acuity
32K papers, 797.1K citations
82% related
Retina
28K papers, 1.2M citations
81% related
Performance
Metrics
No. of papers in the topic in previous years
YearPapers
20231,805
20223,557
2021907
20201,074
20191,127
20181,113