scispace - formally typeset
Search or ask a question
Topic

Optical coherence tomography

About: Optical coherence tomography is a research topic. Over the lifetime, 19051 publications have been published within this topic receiving 477433 citations. The topic is also known as: optical coherent tomography.


Papers
More filters
Journal ArticleDOI
TL;DR: A broadband adaptive optics scanning ophthalmoscope (BAOSO) consisting of four afocal telescopes, formed by pairs of off-axis spherical mirrors in a non-planar arrangement, is presented.
Abstract: A broadband adaptive optics scanning ophthalmoscope (BAOSO) consisting of four afocal telescopes, formed by pairs of off-axis spherical mirrors in a non-planar arrangement, is presented. The non-planar folding of the telescopes is used to simultaneously reduce pupil and image plane astigmatism. The former improves the adaptive optics performance by reducing the root-mean-square (RMS) of the wavefront and the beam wandering due to optical scanning. The latter provides diffraction limited performance over a 3 diopter (D) vergence range. This vergence range allows for the use of any broadband light source(s) in the 450-850 nm wavelength range to simultaneously image any combination of retinal layers. Imaging modalities that could benefit from such a large vergence range are optical coherence tomography (OCT), multi- and hyper-spectral imaging, single- and multi-photon fluorescence. The benefits of the non-planar telescopes in the BAOSO are illustrated by resolving the human foveal photoreceptor mosaic in reflectance using two different superluminescent diodes with 680 and 796 nm peak wavelengths, reaching the eye with a vergence of 0.76 D relative to each other.

279 citations

Journal ArticleDOI
TL;DR: An analysis for polarization-sensitive optical coherence tomography that facilitates the unrestricted use of fiber and fiber-optic components throughout an interferometer and yields sample birefringence, diattenuation, and relative optic axis orientation is presented.
Abstract: We present an analysis for polarization-sensitive optical coherence tomography that facilitates the unrestricted use of fiber and fiber-optic components throughout an interferometer and yields sample birefringence, diattenuation, and relative optic axis orientation. We use a novel Jones matrix approach that compares the polarization states of light reflected from the sample surface with those reflected from within a biological sample for pairs of depth scans. The incident polarization alternated between two states that are perpendicular in a Poincare sphere representation to ensure proper detection of tissue birefringence regardless of optical fiber contributions. The method was validated by comparing the calculated diattenuation of a polarizing sheet, chicken tendon, and muscle with that obtained by independent measurement. The relative importance of diattenuation versus birefringence to angular displacement of Stokes vectors on a Poincare sphere was quantified.

279 citations

Journal ArticleDOI
TL;DR: In this paper, the authors investigated the subfoveal choroidal thickness in eyes with typical age-related macular degeneration (AMD) and polypoidal choroid vasculopathy (PCV), using enhanced depth imaging optical coherence tomography.
Abstract: Purpose To investigate the subfoveal choroidal thickness in eyes with typical age-related macular degeneration (AMD) and polypoidal choroidal vasculopathy (PCV), using enhanced depth imaging optical coherence tomography.

278 citations

Journal ArticleDOI
TL;DR: The system uses two spectrometers, one for each polarization channel, that operate in parallel at 20000 A-lines/s each and provides reflectivity, retardation, and cumulative optic axis orientation simultaneously.
Abstract: We developed a high-speed polarization sensitive optical coherence tomography (PS-OCT) system for retinal imaging based on spectral domain OCT. The system uses two spectrometers, one for each polarization channel, that operate in parallel at 20000 A-lines/s each. It provides reflectivity, retardation, and cumulative optic axis orientation simultaneously. We present our instrument and discuss the requirements for the alignment of the two spectrometers specific for our setup. We show 2D spectral domain PS-OCT images and – to the best of our knowledge – the first 3D spectral domain PS-OCT data sets in form of fly-through movies and volume rendered data sets recorded in human retina in vivo.

278 citations

Journal ArticleDOI
TL;DR: This work built a fiber-based PS-OCT setup that produces quasi-real-time images of the human retina in vivo and preliminary measurements showed that the double-pass phase retardation per unit depth of the RNFL near the optic nerve head is 39±6°/100 µm.
Abstract: To our knowledge, this is the first demonstration of in vivo depth-resolved birefringence measurements of the human retinal nerve fiber layer (RNFL) by use of polarization-sensitive optical coherence tomography (PS-OCT). Because glaucoma causes nerve fiber layer damage, which may cause loss of retinal birefringence, PS-OCT is a potentially useful technique for the early detection of glaucoma. We built a fiber-based PS-OCT setup that produces quasi-real-time images of the human retina in vivo. Preliminary measurements of a healthy volunteer showed that the double-pass phase retardation per unit depth of the RNFL near the optic nerve head is 39±6°/100 µm.

278 citations


Network Information
Related Topics (5)
Retinal
24.4K papers, 718.9K citations
85% related
Lens (optics)
156.4K papers, 1.2M citations
83% related
Glaucoma
31.5K papers, 738.2K citations
82% related
Visual acuity
32K papers, 797.1K citations
82% related
Retina
28K papers, 1.2M citations
81% related
Performance
Metrics
No. of papers in the topic in previous years
YearPapers
20231,805
20223,557
2021907
20201,074
20191,127
20181,113