Journal ArticleDOI
TL;DR: In this article, a cylindrical liquid bridge is initially formed between two circular end-plates, and the plates are then moved apart in a prescribed manner such that the fluid sample is subjected to a strong extensional deformation.
Abstract: ▪ Abstract Filament-stretching rheometers are devices for measuring the extensional viscosity of moderately viscous non-Newtonian fluids such as polymer solutions. In these devices, a cylindrical liquid bridge is initially formed between two circular end-plates. The plates are then moved apart in a prescribed manner such that the fluid sample is subjected to a strong extensional deformation. Asymptotic analysis and numerical computation show that the resulting kinematics closely approximate those of an ideal homogeneous uniaxial elongation. The evolution in the tensile stress (measured mechanically) and the molecular conformation (measured optically) can be followed as functions of the rate of stretching and the total strain imposed. The resulting rheological measurements are a sensitive discriminant of molecularly based constitutive equations proposed for complex fluids. The dynamical response of the elongating filament is also coupled to the extensional rheology of the polymeric test fluid, and this can...

466 citations

Journal ArticleDOI
TL;DR: In this article, a theoretical model for the motion of a human red blood cell in a shear field was developed, which consists of a tank-treading ellipsoidal membrane encapsulating an incompressible Newtonian liquid immersed in a plane shear flow of another incom- pressible liquid.
Abstract: A theoretical model is developed for the motion of a human red blood cell in a shear field. The model consists of a tank-treading ellipsoidal membrane encapsulating an incompressible Newtonian liquid immersed in a plane shear flow of another incom- pressible Newtonian liquid. Equilibrium and energy considerations lead to a solution for the motion of the particle that depends on the ellipsoidal-axis ratios and the ratio of the inner- to outer-liquid viscosities. The effect of variation in these parameters is explored and it is shown that, depending on their values, one of two types of overall motion is exhibited: a steady stationary-orientation motion or an unsteady flipping motion. A qualitative agreement of the predicted behaviour of the model with experi- mental observations on red blood cells is found.

458 citations

Journal ArticleDOI
TL;DR: In this paper, a self-diffusion coefficient for lateral dispersion of spherical and disk-like particles in linear shear flow of a slurry at very low Reynolds number was determined experimentally.
Abstract: Self-diffusion coefficients were determined experimentally for lateral dispersion of spherical and disk-like particles in linear shear flow of a slurry at very low Reynolds number. Using a concentric-cylinder Couette apparatus, recurrent observations were made of the lateral position of a particular radioactively labelled particle. The self-diffusion coefficient D was calculated by means of random-walk theory, using the ergodic hypothesis. Owing to great experimental difficulties, the calculated values of D are not of high accuracy, but are correct to within a factor of two. In the range 0 < ϕ < 0·2, D/a2ω increases from zero linearly with ϕ up to D/a2ω ≅ 0·02 (where ϕ = volumetric concentration of particles, a = particle radius, ω = mean shear rate of suspending fluid). In the range 0·2 < 0·5, the trend of D/a2ω is not clear because of experimental scatter, but in this range D/a2ω ≅ 0·025 to within a factor of two. Within the experimental accuracy, spheres and disks have the same value of D/a2ω.

427 citations

Journal ArticleDOI
14 Jun 2006-Polymer
TL;DR: In this article, the role of fluid elasticity in the formation of fibers from polymer solution by electrospinning is investigated, and a critical value of elastic stress in the jet, expressed as a function of jet radius and capillary number, is shown to indicate complete suppression of the Rayleigh instability and the transition from beads-on-string to uniform fiber morphology.

382 citations

Journal ArticleDOI
TL;DR: In this article, a sliding plate rheometer with a high density polyethylene was used to determine the conditions for the onset of slip and the relationship between slip velocity and shear stress.
Abstract: Experiments were performed in a sliding plate rheometer with a high density polyethylene to determine the conditions for the onset of slip and the relationship between slip velocity and shear stress. It was found that melt slip occurs at a critical shear stress of approximately 0.09 MPa in both steady and transient shear tests. The effect of the presence of a layer of fluorocarbon at the interface on both the slip velocity and the critical shear stress for the onset of slip, was also studied. Exponential shear was used to study the effect of shear history on slip. Both steady state and dynamic models for the slip velocity are proposed that are consistent with the experimental observations. Results of oscillatory shear experiments suggest that melt slip is a physicochemical process in which the polymer–wall interface undergoes continuous change during successive cycles.

343 citations


Network Information
Related Topics (5)
Polymer
131.4K papers, 2.6M citations
84% related
Phase (matter)
115.6K papers, 2.1M citations
81% related
Ultimate tensile strength
129.2K papers, 2.1M citations
81% related
Particle size
69.8K papers, 1.7M citations
81% related
Polymerization
147.9K papers, 2.7M citations
80% related
Performance
Metrics
No. of papers in the topic in previous years
YearPapers
2023240
2022487
2021164
2020196
2019201
2018162