scispace - formally typeset
Search or ask a question
Topic

Ventricle

About: Ventricle is a research topic. Over the lifetime, 21456 publications have been published within this topic receiving 507177 citations.


Papers
More filters
Journal ArticleDOI
TL;DR: It is indicated that after anterior myocardial infarction, ventricular enlargement is progressive and that captopril may attenuate this process, reduce filling pressures, and improve exercise tolerance.
Abstract: We conducted a double-blind, placebo-controlled trial to determine whether ventricular dilatation continues during the late convalescent phase after myocardial infarction and whether therapy with captopril alters this process. Fifty-nine patients with a first anterior myocardial infarction and a radionuclide ejection fraction of 45 percent or less underwent cardiac catheterization 11 to 31 days after infarction, when they were not in overt congestive heart failure. They were randomly assigned to placebo or captopril and were followed for one year. A repeat catheterization was performed to evaluate interval changes in hemodynamic function and left ventricular volume. Thirty-eight male patients were evaluated with maximal-exercise treadmill tests every three months. No differences were detected at base line in clinical, hemodynamic, or quantitative ventriculographic variables. During one year of follow-up, the end-diastolic volume of the left ventricle increased by a mean [±SEM] of 21 ±8 ml (P<0.02...

1,080 citations

Journal ArticleDOI
01 Mar 1981-Heart
TL;DR: Models based on uniform myocardial fibre structure cannot explain wall movement in normal subjects, and are likely to have significant limitations if used to investigated left ventricular function in disease.
Abstract: In order to investigate the possibility of regional variation of ventricular structure, 25 normal postmortem human hearts were studied by inspection of cavity shape and subepicardial fibre orientation, by dissection, and by the histology of sections in two orthogonal planes. Ventricular architecture was complex. Inlet and outlet long axes were separated by 30 degrees in the left ventricle. In the right the corresponding figure was 90 degrees. The thickest part of the left ventricular wall was at the base. At the apex there was potential endo- and epicardial continuity. Left ventricular cavity shape departed significantly from any simple geometric figure, there being, consistently, regions of both positive and negative curvature on the diaphragmatic aspect. The presence of trabeculae caused considerable variation in wall thickness. Striking variation was found in the arrangement of subepicardial muscle fibres. Most pronounced was the contrast between the longitudinal arrangement of fibres observed on the oblique margin and the circumferential arrangement of those on the acute. On the diaphragmatic surface of the left ventricle, fibres near the crux and apex ran circumferentially while those between ran obliquely; those on the diaphragmatic surface of the right ventricle also ran circumferentially. Deeper in the myocardium the arrangement was simpler. In the mid-wall of the left ventricle fibres were circumferential, best developed towards the base and in the upper part of the septum. Near the apex of the left ventricle and in the mid-wall of the right ventricle such fibres were sparse. The subendocardial region consisted of longitudinally directed fibres forming the trabeculae and papillary muscles, while fibres deep to and between the trabeculae coursed more obliquely. These findings were confirmed by histology. Models based on uniform myocardial fibre structure cannot explain wall movement in normal subjects, and are likely to have significant limitations if used to investigated left ventricular function in disease.

1,046 citations

Journal ArticleDOI
TL;DR: It is shown that percutaneous valve replacement in the pulmonary position is possible and with further technical improvements, this new technique might also be used for valve Replacement in other cardiac and non-cardiac positions.

1,028 citations

Journal ArticleDOI
TL;DR: Simultaneous continuous wave Doppler echocardiography and right-sided cardiac pressure measurements were performed during cardiac catheterization in 127 patients and approximately 80% of patients with increased and 57% with normal right ventricular pressure had analyzable Dopplers tricuspid regurgitant velocities that could be used to accurately predictright ventricular systolic pressure.

980 citations

Journal ArticleDOI
TL;DR: It is concluded that the conductance catheter provides a reliable and simple method to measure left ventricular volume, giving an on-line, time-varying signal that is easily calibrated.
Abstract: An eight-electrode conductance catheter previously developed by us and used to determine stroke volume in dogs was applied in human beings and dogs to measure absolute left ventricular volume quantitatively. For calibration we developed the formula V(t) = (1/alpha)(L2/sigma b)G(t) - Vc, where V(t) is time-varying left ventricular volume, alpha is a dimensionless constant, L is the electrode separation, sigma b is the conductivity of blood obtained by a sampling cuvette, and G(t) is the measured conductance within the left ventricular cavity. Vc is a correction term caused by the parallel conductance of structures surrounding the cavity and is measured in two ways. The first method, applicable in the anesthetized animal, consists of temporary reduction of volume to zero by suction. The second method uses a transient change in sigma b by injection of a small bolus of hypertonic saline (dogs) or 10 ml of cold glucose (humans) into the pulmonary artery. The validity of the formula was previously established for the isolated postmortem canine heart. The predicted linearity, slope constant alpha, and accuracy of Vc for the left ventricle in vivo were investigated by comparing the conductance volume data with results from independent methods: electromagnetic blood flow measurement for stroke volume and indicator dilution technique for ejection fraction (dogs), thermal dilution for cardiac output (12 patients), and single-plane cineventriculography for V(t) (five patients). In all comparisons, linear regression showed high correlation (from r = .82 [n = 46] to r = .988 [n = 20]) while alpha, with one exception, ranged from 0.75 to 1.07 and the error in Vc ranged from 0.5% to 16.5% (mean 7%). After positioning of the catheter, no arrhythmias were observed. It is concluded that the conductance catheter provides a reliable and simple method to measure left ventricular volume, giving an on-line, time-varying signal that is easily calibrated. Together with left ventricular pressure obtained through the catheter lumen, the instrument may be used for instantaneous display of pressure-volume loops to facilitate assessment of left ventricular pump performance.

951 citations


Network Information
Related Topics (5)
Ejection fraction
47.6K papers, 1.6M citations
93% related
Heart failure
107.8K papers, 3.5M citations
93% related
Heart disease
42.8K papers, 1.6M citations
92% related
Coronary artery disease
77.6K papers, 2.2M citations
92% related
Myocardial infarction
119K papers, 4.2M citations
92% related
Performance
Metrics
No. of papers in the topic in previous years
YearPapers
20231,794
20223,888
2021648
2020599
2019574
2018582