scispace - formally typeset
Search or ask a question
Topic

Zernike polynomials

About: Zernike polynomials is a research topic. Over the lifetime, 4271 publications have been published within this topic receiving 68621 citations.


Papers
More filters
Journal ArticleDOI
TL;DR: It is inferred that subjective best focus occurs when the area of the central, aberration-free region of the pupil is maximized, and that correction of the 12 largest principal components, or 14 largest Zernike modes, would be required to achieve diffraction-limited performance on average for a 6-mm pupil.
Abstract: A Shack-Hartmann aberrometer was used to measure the monochromatic aberration structure along the primary line of sight of 200 cyclopleged, normal, healthy eyes from 100 individuals. Sphero-cylindrical refractive errors were corrected with ophthalmic spectacle lenses based on the results of a subjective refraction performed immediately prior to experimentation. Zernike expansions of the experimental wave-front aberration functions were used to determine aberration coefficients for a series of pupil diameters. The residual Zernike coefficients for defocus were not zero but varied systematically with pupil diameter and with the Zernike coefficient for spherical aberration in a way that maximizes visual acuity. We infer from these results that subjective best focus occurs when the area of the central, aberration-free region of the pupil is maximized. We found that the population averages of Zernike coefficients were nearly zero for all of the higher-order modes except spherical aberration. This result indicates that a hypothetical average eye representing the central tendency of the population is nearly free of aberrations, suggesting the possible influence of an emmetropization process or evolutionary pressure. However, for any individual eye the aberration coefficients were rarely zero for any Zernike mode. To first approximation, wave-front error fell exponentially with Zernike order and increased linearly with pupil area. On average, the total wave-front variance produced by higher-order aberrations was less than the wave-front variance of residual defocus and astigmatism. For example, the average amount of higher-order aberrations present for a 7.5-mm pupil was equivalent to the wave-front error produced by less than 1/4 diopter (D) of defocus. The largest pupil for which an eye may be considered diffraction-limited was 1.22 mm on average. Correlation of aberrations from the left and right eyes indicated the presence of significant bilateral symmetry. No evidence was found of a universal anatomical feature responsible for third-order optical aberrations. Using the Marechal criterion, we conclude that correction of the 12 largest principal components, or 14 largest Zernike modes, would be required to achieve diffraction-limited performance on average for a 6-mm pupil. Different methods of computing population averages provided upper and lower limits to the mean optical transfer function and mean point-spread function for our population of eyes.

615 citations

Journal ArticleDOI
TL;DR: In this paper, a modified Hartmann-Shack wavefront sensor was used to measure the monochromatic wave aberration of both eyes for 109 normal human subjects across a 5.7mm pupil.
Abstract: From both a fundamental and a clinical point of view, it is necessary to know the distribution of the eye's aberrations in the normal population and to be able to describe them as efficiently as possible. We used a modified Hartmann-Shack wave-front sensor to measure the monochromatic wave aberration of both eyes for 109 normal human subjects across a 5.7-mm pupil. We analyzed the distribution of the eye's aberrations in the population and found that most Zernike modes are relatively uncorrelated with each other across the population. A principal components analysis was applied to our wave-aberration measurements with the resulting principal components providing only a slightly more compact description of the population data than Zernike modes. This indicates that Zernike modes are efficient basis functions for describing the eye's wave aberration. Even though there appears to be a random variation in the eye's aberrations from subject to subject, many aberrations in the left eye were found to be significantly correlated with their counterparts in the right eye.

614 citations

Journal ArticleDOI
TL;DR: It is shown that the Krawtchouk moments can be employed to extract local features of an image, unlike other orthogonal moments, which generally capture the global features.
Abstract: A new set of orthogonal moments based on the discrete classical Krawtchouk polynomials is introduced. The Krawtchouk polynomials are scaled to ensure numerical stability, thus creating a set of weighted Krawtchouk polynomials. The set of proposed Krawtchouk moments is then derived from the weighted Krawtchouk polynomials. The orthogonality of the proposed moments ensures minimal information redundancy. No numerical approximation is involved in deriving the moments, since the weighted Krawtchouk polynomials are discrete. These properties make the Krawtchouk moments well suited as pattern features in the analysis of two-dimensional images. It is shown that the Krawtchouk moments can be employed to extract local features of an image, unlike other orthogonal moments, which generally capture the global features. The computational aspects of the moments using the recursive and symmetry properties are discussed. The theoretical framework is validated by an experiment on image reconstruction using Krawtchouk moments and the results are compared to that of Zernike, pseudo-Zernike, Legendre, and Tchebyscheff moments. Krawtchouk moment invariants are constructed using a linear combination of geometric moment invariants; an object recognition experiment shows Krawtchouk moment invariants perform significantly better than Hu's moment invariants in both noise-free and noisy conditions.

610 citations

Journal ArticleDOI
TL;DR: The authors show that the new method of deriving Zernike moment invariants along with the new normalization scheme yield the best overall performance even when the data are degraded by additive noise.

532 citations

Journal ArticleDOI
TL;DR: An adaptive confocal fluorescence microscope incorporating this modal sensor together with a deformable membrane mirror for aberration correction is demonstrated, which shows considerable improvement in contrast and apparent restoration of axial resolution.
Abstract: The main advantage of confocal microscopes over their conventional counterparts is their ability to optically “section” thick specimens; the thin image slices thus obtained can be used to reconstruct three-dimensional images, a capability which is particularly useful in biological applications. However, it is well known that the resolution and optical sectioning ability can be severely degraded by system or specimen-induced aberrations. The use of high aperture lenses further exacerbates the problem. Moreover, aberrations can considerably reduce the number of photons that reach the detector, leading to lower contrast. It is rather unfortunate, therefore, that in practical microscopy, aberration-free confocal imaging is rarely achieved. Adaptive optics systems, which have been used widely to correct aberrations in astronomy, offer a solution here but also present new challenges. The optical system and the source of aberrations in a confocal microscope are considerably different and require a novel approach to wavefront sensing. This method, based upon direct measurement of Zernike aberration modes, also exhibits an axial selectivity similar to that of a confocal microscope. We demonstrate an adaptive confocal fluorescence microscope incorporating this modal sensor together with a deformable membrane mirror for aberration correction. Aberration corrected images of biological specimens show considerable improvement in contrast and apparent restoration of axial resolution.

472 citations


Network Information
Related Topics (5)
Lens (optics)
156.4K papers, 1.2M citations
83% related
Image processing
229.9K papers, 3.5M citations
83% related
Optical fiber
167K papers, 1.8M citations
81% related
Laser
353.1K papers, 4.3M citations
80% related
Pixel
136.5K papers, 1.5M citations
79% related
Performance
Metrics
No. of papers in the topic in previous years
YearPapers
2023117
2022261
2021125
2020188
2019218
2018187