J.A.S.B. Jayasinghe is an academic researcher from University of Bath. The author has contributed to research in topics: Partial discharge & Electric power transmission. The author has an hindex of 2, co-authored 5 publications receiving 145 citations.

Papers
More filters
Journal ArticleDOI

An overview of the condition monitoring of overhead lines

TL;DR: In this article, the authors reviewed the investigation into overhead line deterioration, briefly outlined the inspection methods available at present, and finally introduced a current project being undertaken in the Power and Energy Systems Research Group at the University of Bath in collaboration with two major utilities in the UK, into on-line condition monitoring of overhead lines.
Journal ArticleDOI

A novel non-unit protection for series compensated EHV transmission lines based on fault generated high frequency voltage signals

TL;DR: In this article, a high speed protection technique based on fault generated high frequency (HF) voltage signals is developed and applied to the protection of EHV series compensated power transmission lines.
Proceedings ArticleDOI

A new approach to condition monitoring of high voltage overhead lines using neural networks

TL;DR: In this article, the authors describe the design of a condition monitoring technique for overhead transmission lines using artificial neural networks (ANNs), which is based on utilising the high frequency phenomenon associated with the partial discharge (PD) activity emanating from various line conductor defects.
Proceedings ArticleDOI

Simulation of the partial discharge phenomena in defective overhead line conductors through an empirical approach

TL;DR: In this paper, a simulation technique for modeling the partial discharge (PD) phenomena associated with defective conductors on overhead transmission lines is presented, based on an empirical approach, and compared with actual laboratory tests carried out on a typical 400 kV conductor subjected to defects commonly encountered under service conditions.
Proceedings ArticleDOI

An experimental investigation into the partial discharge phenomenon in defective high-voltage conductors

TL;DR: In this article, the authors present the results of an experimental study on the partial discharge (PD) characteristics of a single EHV overhead line conductor under AC voltage conditions in a metal cage.