scispace - formally typeset
Search or ask a question

Showing papers by "Jie Li published in 2022"


Journal ArticleDOI
TL;DR: In this paper , the authors investigated the association between heart rate within 24 hours of admission to the ICU and 30-day mortality among patients with atrial fibrillation and ischemic stroke.
Abstract: Background The relationship of mean heart rate (MHR) with 30-day mortality in ischemic stroke patients with atrial fibrillation in the intensive care unit (ICU) remains unknown. This study aimed to investigate the association between MHR within 24 h of admission to the ICU and 30-day mortality among patients with atrial fibrillation and ischemic stroke. Methods This retrospective cohort study used data on US adults from the Medical Information Mart for Intensive Care-IV (MIMIC-IV, version 1.0) database. Patients with ischemic stroke who had atrial fibrillation for and first time in ICU admission were identified from the MIMIC-IV database. We used multivariable Cox regression models, a restricted cubic spline model, and a two-piecewise Cox regression model to show the effect of the MHR within 24 h of ICU admission on 30-day mortality. Results A total of 1403 patients with ischemic stroke and atrial fibrillation (mean [SD] age, 75.9 [11.4] years; mean [SD] heart rate, 83.8[16.1] bpm; 743 [53.0%] females) were included. A total of 212 (15.1%) patients died within 30 days after ICU admission. When MHR was assessed in tertials according to the 25th and 50th percentiles, the risk of 30-day mortality was higher in participants in group 1 (< 72 bpm; adjusted hazard ratio, 1.23; 95% CI, 0.79–1.91) and group 3 (≥82 bpm; adjusted hazard ratio, 1.77; 95% CI, 1.23–2.57) compared with those in group 2 (72–82 bpm). Consistently in the threshold analysis, for every 1-bpm increase in MHR, there was a 2.4% increase in 30-day mortality (adjusted HR, 1.024; 95% CI, 1.01–1.039) in those with MHR above 80 bpm. Based on these results, there was a J-shaped association between MHR and 30-day mortality in ischemic stroke patients with atrial fibrillation admitted to the ICU, with an inflection point at 80 bpm of MHR. Conclusion In this retrospective cohort study, MHR within 24 h of admission was associated with 30-day mortality (nonlinear, J-shaped association) in patients with ischemic stroke and atrial fibrillation in the ICU, with an inflection point at about 80 bpm and a minimal risk observed at 72 to 81 bpm of MHR. This association was worthy of further investigation. If further confirmed, this association may provide a theoretical basis for formulating the target strategy of heart rate therapy for these patients.

1 citations


Journal ArticleDOI
01 Sep 2022
TL;DR: In this paper , a quantitative method for the simultaneous determination of 22 functional components in cosmetics was established by ultra-high performance liquid chromatography-linear ion trap/orbitrap high resolution mass spectrometry (UHPLC-LTQ/Orbitrap MS).
Abstract: Plant components from extracts of Sophora flavescens, rhodiola, ginseng, Centella asiatica, and tea play important roles in skin whitening, moisturizing, anti-aging, sun protection, anti-inflammation, antiseptic, bacteriostatic, and other effects of cosmetics. At present, no relevant standard methods have been established to detect the addition amounts of plant extracts in cosmetics. In addition, plant extracts listed in product labels may be undetectable due to their addition in trace quantities and the lack of technical support. Therefore, a quantitative method for the simultaneous determination of 22 functional components in cosmetics was established by ultra-high performance liquid chromatography-linear ion trap/orbitrap high resolution mass spectrometry (UHPLC-LTQ/Orbitrap MS). Target compounds were extracted with methanol from samples using ultrasonic extraction, and then separated on a C18 column (100 mm × 2.1 mm, 1.8 μm) with gradient elution of 0.1% (v/v) formic acid aqueous solution (A) and acetonitrile (B). The gradient elution program were as follows: 0-5 min, 5%B-8%B; 5-25 min, 8%B-60%B; 25-35 min, 60%B-80%B; 35-36 min, 80%B-5%B; 36-45 min, 5%B. The flow rate was 0.3 mL/min and the injection volume was 5 μL. Accurate masses of precursor ions were used to detect cosmetic functional components in positive ionization mode. The fragment ions obtained by higher energy collisional dissociation were used for confirmation of the functional components. Each compound showed good linearity. The limits of detection (LODs) were in the range of 0.003-2.01 mg/kg, and the limits of quantification (LOQs) were in the range of 0.02-4.36 mg/kg. Recoveries at three levels were 63.2%-125.1%, and relative standard deviations (RSDs) were 0.18%-10.9%. Fifty-four batches of samples labeled with four monomer functional components and nine plant extracts were tested. In the 17 batches of samples labeled with nicotinamide, 4 batches labeled with caffeine, and 6 batches labeled with Sophora flavescens root extract, the labeled functional components were detected. One out of 11 batches of samples labeled with D-panthenol was not detected. Three of the seven batches of samples labeled with ascorbyl glucoside were not detected. In the 21 batches of samples labeled with licorice extracts, the corresponding functional components were not detected in 9 batches. In the 21 batches of samples labeled with Centella asiatica extract, the corresponding functional components were not detected in 11 batches. In the 13 batches of samples labeled with tea extract, the corresponding functional components were not detected in 8 batches. In 11 of the 12 batches containing ginseng root extract, the corresponding functional components were not detected. In five of the six batches of astragalus membranaceus root extract samples, the corresponding functional components were not detected. In samples labeled with Polygonum cuspidatum root extract, Rehmannia glutinosa root extract, and Ophiopogon japonicus root extract, the corresponding functional components were detected. The method is simple, rapid, reliable, accurate, and suitable for the determination of the 22 functional components in cosmetics.