Showing papers by "Ulrich Speck published in 2022"


Journal ArticleDOI
TL;DR: In this article , a double-dose DCB with 6-µg paclitaxel (Ptx)/mm2 balloon surface (1 × 6) was compared to a standard DCB (3.5 µg Ptx/mm2) and uncoated balloons (POBA).
Abstract: Clinical data indicate that the drug density on drug-coated balloons (DCBs) might have a role on treatment effect and durability. The aim of the current study was to investigate inhibition of neointimal formation and potential adverse effects after treatment with a novel double-dose DCB in swine.A four-week study was performed in peripheral arteries of 12 domestic pigs after vessel injury and stent implantation. The novel double-dose DCB with 6-µg paclitaxel (Ptx)/mm2 balloon surface (1 × 6) was compared to a standard DCB with 3.5 µg Ptx/mm2 (3.5) and uncoated balloons (POBA). Potential adverse effects were stimulated by using three fully overlapping DCBs with 6 µg Ptx/mm2 each (3 × 6). Quantitative angiography, histomorphometry and histopathological analyses were performed.Higher paclitaxel doses per square millimeter of treated arteries were associated with reduced late lumen loss (LLL) in quantitative angiography 4 weeks after treatment (POBA: 0.91 ± 0.75 mm; 3.5: 0.45 ± 0.53 mm; 1 × 6: 0.21 ± 0.41 mm; 3 × 6: - 0.38 ± 0.65 mm). In histomorphometry, maximal neointimal thickness and neointimal area were the lowest for the 1 × 6 group (0.15 ± 0.06 mm/1.5 ± 0.4 mm2), followed by 3 × 6 (0.20 ± 0.07 mm/1.8 ± 0.4 mm2), 3.5 (0.22 ± 0.12 mm/2.2 ± 1.1 mm2) and POBA (0.30 ± 0.07 mm/3.2 ± 0.7 mm2). Downstream tissue showed histopathological changes in all groups including POBA, in larger number and different quality (e.g., edema, inflammation, vessel wall necrosis, vasculitis and perivasculitis) in the 3 × 6 group, which did not cause clinical or functional abnormalities throughout the study.Treatment with the double-dose DCB (6 µg Ptx/mm2) tended to increase inhibition of in-stent neointimal formation and to diminish LLL after peripheral intervention in the porcine model compared to a market-approved DCB with 3.5 µg Ptx/mm2.

2 citations


Journal ArticleDOI
TL;DR: In this article , drug-coated balloon surfaces were tested with respect to dissolution in organic solvents, coating on balloons, and drug transfer to the vessel wall, and none of the tested coatings significantly reduced in-stent neointimal proliferation compared to uncoated balloons.
Abstract: BACKGROUND Although controversially discussed, paclitaxel is the only clinically proven drug that inhibits restenosis when released from drug-coated balloons (DCBs). Limus drugs are currently being explored as alternatives. The aim of the preclinical studies was to investigate drug candidates beyond paclitaxel considered for balloon coating. METHODS Drugs were tested with respect to dissolution in organic solvents, coating on balloons, and drug transfer to the vessel wall. Inhibition of neointimal proliferation was tested in the porcine model of coronary in-stent stenosis. Intravascular drug treatment was achieved by DCBs at the time of stent implantation. RESULTS Coating had to be adjusted for each drug. Doses on the balloons ranged from 1.0 to 8.6 μg/mm2 balloon surface. Satisfactory amounts of drug ranging from 5% to 29% of initial doses were transferred into the vessel wall. Angiographic parameters such as late lumen loss (LLL) at 4 weeks did not show reduction of in-stent neointimal proliferation by treatment with arsenic trioxide (0.87 ± 0.44 mm), betamethasone dipropionate (1.00 ± 0.54 mm), bortezomib (1.74 ± 0.46 mm), green tea extract (1.24 ± 0.51 mm), fantolon, an epothilone (0.86 ± 0.61 mm), methotrexate (1.09 ± 0.72 mm), and thalidomide (1.59 ± 0.55 mm) compared to treatment with uncoated balloons (1.07 ± 0.60 mm), while coatings with paclitaxel reliably reduced in-stent stenosis (LLL = 0.36 ± 0.25 mm). CONCLUSIONS Despite the proven antiproliferative and/or anti-inflammatory effect of the drugs, none of the coatings significantly reduced LLL compared to uncoated balloons and thus, based on the results presented here, none of the tested coatings may be considered a substitute for the paclitaxel-based coatings currently in clinical use.