Design of a wire imaging synchrotron radiation detector
J. Kent,J.J. Gomez Cadenas,A. Hogan,M. King,W.A. Rowe,S. Watson,C. von Zanthier,D. Briggs,Michael Levi +8 more
Reads0
Chats0
TLDR
In this paper, the design of a detector invented to measure the positions of synchrotron radiation beams for the precision energy spectrometers of the Stanford Linear Collider (SLC) is described.Abstract:
The design of a detector invented to measure the positions of synchrotron radiation beams for the precision energy spectrometers of the Stanford Linear Collider (SLC) is described. The energy measurements involve the determination, on a pulse-by-pulse basis, of the separation of pairs of intense beams of synchrotron photons in the megaelectronvolt energy range. The detector intercepts the beams with arrays of fine wires. The ejection of Compton recoil electrons results in charges being developed in the wires, thus enabling a determination of beam positions. >read more
Citations
More filters
Journal ArticleDOI
Polarisation and Beam Energy Measurement at a Linear $e^+e^-$ Collider
TL;DR: In this paper, the foreseen concepts of beam energy and beam polarisation measurement at the International Linear Collider (ILC) were discussed, and a noninvasive energy spectrometer based on beam position monitors was introduced.
Journal ArticleDOI
The electronics and data acquisition system for the wire imaging synchrotron radiation detector at the SLC
TL;DR: The Stanford Large Collider (SLC) at Stanford Linear Accelerator Center collides electrons and positrons produced in the linear accelerator pulse by pulse The energy of each beam is determined by measuring the angle of deflection of the beam in the SLC extraction lines as mentioned in this paper.
The electronics and data acquisition system for the Wire Imaging Synchrotron Radiation Detector at the SLC (Stanford Linear Collider)
TL;DR: In this article, the authors measured the energy of each beam by measuring the angle of deflection of the beam in the SLC extraction lines, which consists of two bending magnets that produce synchrotron radiation, and a spectrometer analyzing magnet that deflects the beam.
Journal ArticleDOI
Initial performance of the Wire Imaging Synchrotron Radiation Detector
C. von Zanthier,J.J. Gomez Cadenas,J. Kent,M. King,S. Watson,D. Briggs,F. Rouse,John Tinsman +7 more
TL;DR: WireWire Imaging Synchrotron Radiation Detector (WISRDE) as mentioned in this paper was proposed to measure the positions of intense synchron-radiation beams with high precision, and it was used for the precision energy spectrometers of the SLC.
Pulse-by-pulse energy measurement at the stanford linear collider*
TL;DR: Wire- Imaging Synchrotron Radiation Detector (WISRD) as mentioned in this paper is one of the first detectors for high-energy physics measurements. But it is not suitable for high energy physics applications.