scispace - formally typeset
Open AccessJournal ArticleDOI

Local Diagnostic Reference Levels for Common Pediatric X-Ray Examinations in Khorasan Razavi Province, Iran

TLDR
The findings revealed that local DRLs in this study are higher than the corresponding values, recommended by the Commission of European Communities (CEC) and National Radiological Protection Board (NRBP), which were related to the use of low kVp, relatively high mAs in all centers, and use of grid for most of the patients.
Abstract
Introduction Given the fact that children are more sensitive to radiation, compared to adults, special attention needs to be paid to radiation protection in pediatric radiology. Diagnostic reference level (DRL) has been defined to be employed as a practical tool for examining the overall performance of a radiological center in terms of patient dose among a series of similar equipments in an area or an institution as a Local DRL (LDRL). Materials and Methods To establish DRL for diagnostic X-ray examinations of children in KhorasanRazavi province, data were collected from 627 pediatric patients. The average of entrance surface doses (ESDs), arising from chest and abdomen examinations, were examined for three different age groups. Results Local DRL (LDRL) were calculated to be 77, 126, and 138 µGy for chest examinations of <1-month-old, 1-12-month-old, and 1-5-year-old groups, respectively. The corresponding values obtained from abdomen radiographies were 152, 120, and 280 µGy, respectively. Conclusion Our findings revealed that local DRLs in this study are higher than the corresponding values, recommended by the Commission of European Communities (CEC) and National Radiological Protection Board (NRBP). Higher ESDs acquired for chest examination were related to the use of low kVp, relatively high mAs in all centers, and use of grid for most of the patients.

read more

Citations
More filters
Journal ArticleDOI

Dose Reduction to the Thyroid Gland in Pediatric Chest Radiography

TL;DR: The use of thyroid shield in the AP projection of pediatric chest radiography may be an effective method to reduce patient's radiation risk and its usage should be encouraged.
Journal ArticleDOI

Local Diagnostic Reference Levels for Some Common Diagnostic X-Ray Examinations In Sabzevar County of Iran

TL;DR: The ESDs obtained in this study for the chest PA, cervical AP, cervical LAT, AP and LAT skull, abdomen AP, pelvis AP, lumbar PA, and lumberar LAT examinations did not exceed the DRL values reported by NPRB.
Journal ArticleDOI

Radiophilia: A Common Case of Excessive Radiation Exposure inHealthcare

TL;DR: A common case of excessive radiation exposure in healthcare is reported, defined as “unnecessary radiation exposure due to misunderstanding and underestimation of risk perception, risk conception and risk communication among healthcare employees involved in medical radiation imaging”.
Journal ArticleDOI

An Estimate of Radiation Dose to the Lens of the Eyes, Parotid Gland, and Thyroid Gland in Dental Panoramic Radiography

TL;DR: The absorbed dose received by the lens of the eyes and thyroid gland was generally lower than the values reported in similar studies, but the parotid gland in the SA Hospital exceeded the recommended dose reference level of 400 µGy in DPR.
Journal ArticleDOI

The abdominal radiation doses for paediatric patients undergoing X-ray examinations at southern Saudi Arabia.

TL;DR: The results are useful to the National Centre for Radiation Protection in Saudi Arabia and other professional organizations elsewhere, to set up safety protocols to prevent paediatric patients from needless radiation and to establish diagnostic reference levels (DRLs).
References
More filters

Doses to Patients from Medical X-ray Examinations in the UK - 2000 Review

TL;DR: Reference doses have been derived for a larger number of examinations on adults than previously and, for the first time, for three examinations on children, with specific values for five standard-sized patients corresponding to new born babies, 1, 5, 10 and 15 year olds.
Journal ArticleDOI

Digital radiography: the balance between image quality and required radiation dose.

TL;DR: The use of image quality classes according to the dose requirements of given clinical indications are a further step toward modern radiation protection and implementation of dose indicators and dose monitoring is mandatory for digital radiography.
Journal ArticleDOI

Assessment of radiation dose awareness among pediatricians

TL;DR: Awareness of radiation protection issues among pediatricians is generally low, with widespread underestimation of relative doses and risks.
Journal ArticleDOI

UK population dose from medical X-ray examinations.

TL;DR: The annual per caput effective dose for the UK in 2001/2002 was estimated at 0.38 mSv, which is low in comparison with other countries having similarly developed systems of health-care and generally lower doses in the UK than in other developed countries.
Related Papers (5)