The ABM 8057 utilization for SEMONT's EMF monitoring in a closed room

Reads0
Chats0
TLDR
The monitoring was conducted during real daily conditions and student's presence inside of the amphitheater, showing that the high-frequency electric field strength values are far below the Serbian's prescribed reference levels.
Abstract
The Serbian Electromagnetic Field Monitoring Network — SEMONT has started with test monitoring of electromagnetic field (EMF) in a closed room. In this paper, the case study of the high-frequency electric field strength monitoring is presented, utilizing Narda AMB 8057/03 monitoring station. The monitoring procedure has been simultaneously performed in frequency ranges of 100 kHz–7 GHz, GSM 900, GSM 1800 and UMTS 2100, in a closed room of largest amphitheater of the Faculty of Technical Science, University of Novi Sad. The monitoring was conducted during real daily conditions and student's presence inside of the amphitheater, showing that the high-frequency electric field strength values are far below the Serbian's prescribed reference levels.

read more

Citations
More filters
Proceedings ArticleDOI

Networks of EMF Area Monitor for Distributed Human Exposure Monitoring: Assessment of Performances in Simulated Realistic Scenarios

TL;DR: In this paper , an experimental activity has been performed to evaluate this kind of adverse phenomena and the effectiveness of possible countermeasures and the results of this experimental activity are described in the paper.
References
More filters
Journal ArticleDOI

Electromagnetic field exposure assessment in Europe radiofrequency fields (10 MHz-6 GHz).

TL;DR: An overview of the scientific literature on RF EMF exposure in Europe is presented and three population exposure categories (intermittent variable partial body exposure, intermittent variable low-level whole-body (WB) exposure and continuous low- level WB exposure) were recognized by the authors as informative for possible future risk assessment.
Journal ArticleDOI

The SEMONT continuous monitoring of daily EMF exposure in an open area environment

TL;DR: Monitoring of the SEMONT initial campaign of continuous monitoring of the high-frequency electric field strength over the campus of the University of Novi Sad suggests that potential exposure is far below the allowable limit, regarding reference levels prescribed by the Serbian legislation for the general population.
Journal ArticleDOI

The adaptive boundary approach for exposure assessment in a broadband EMF monitoring

TL;DR: In this article, the enhancement of the boundary approach is presented, which is based on the determination of the daily upper and lower exposure boundaries, combining data of the continuous in situ EMF monitoring in a broadband frequency range and the minimal and maximal prescribed reference levels.
Proceedings ArticleDOI

The AMB 8057-03 sensor node implementation in the SEMONT EMF monitoring system

TL;DR: The potential utilization of Narda sensor node AMB 8057-03 in the SEMONT system was investigated and a number of tests have been performed, in order to determine the compliance of AMB8057- 03 with the SEMont requirements.
Related Papers (5)