scispace - formally typeset
Search or ask a question

Showing papers by "Luiz Antonio Daniel published in 2022"


Journal ArticleDOI
TL;DR: In this paper, granular activated carbon (GAC) was used for post-treatment of anaerobic effluent in pilot scale and its performance in removing organic matter and turbidity was evaluated.

3 citations


Journal ArticleDOI
TL;DR: The results endorse the importance of removing the AOM before the disinfection process to avoid the formation of DBPs, and ecotoxicological analyses could provide a more comprehensive assessment of water quality, especially considering the challenges of quantifying DBPs and other emerging contaminants.

2 citations


Journal ArticleDOI
TL;DR: In this paper, three harvesting methods were evaluated: (1) flocculation induced by pH modulation followed by sedimentation (pH-SED), (2) coagulation using an organic coagulant (Tanfloc SG) followed by dissolved air flotation (Coag-DAF).

2 citations


Journal ArticleDOI
TL;DR: In this article , the performance of three Moving Bed Biofilm Reactors (MBBR) using different carriers (with and without protected surface area) were evaluated for domestic wastewater treatment in continuous flow.
Abstract: Biological reactors with immobilized biomass on free carriers have provided new perspectives for wastewater treatment, once they reduce the system size and increase the treatment capacity. In this study, the performance of three Moving Bed Biofilm Reactors (MBBR) using different carriers (with and without protected surface area) were evaluated for domestic wastewater treatment in continuous flow. Each MBBRs (i.e., R1, R2, and R3) was filled at a ratio of 50% with high-density polyethylene carriers with different characteristics: both R1-K1 and R2-Corrugated tube with protected surface and R3-HDPE flakes without protected surface. Chemical oxygen demand (COD) removal of 80 ± 5.0, 80 ± 3.5, and 78 ± 2.4% was achieved by R1, R2, and R3, respectively. The oxygen uptake by biofilm attached on the carriers was 0.0079 ± 0.0013, 0.0033 ± 0.0015, and 0.0031 ± 0.0026 μg DO·mm−2 for the K1, corrugated tube, and HDPE flakes, respectively. No significant differences were observed between the performance of the three MBBRs in terms of physico-chemical parameters (alkalinity, pH, and dissolved inorganic carbon) and COD removal. Results showed that the carrier type and its characteristics (total area and with/without protected area) did not affect the organic matter removal. Thus, the carrier without a protected surface in MBBR could be a promising low-cost option for domestic wastewater treatment.

2 citations