scispace - formally typeset
Search or ask a question

Showing papers by "V. K. Unnikrishnan published in 2012"


Journal ArticleDOI
12 Jun 2012-Pramana
TL;DR: The application of calibration-free laser-induced breakdown spectroscopy for quantitative analysis of materials, illustrated by CF-LIBS applied to a brass sample of known composition, is presented in this article.
Abstract: The application of calibration-free laser-induced breakdown spectroscopy (CF-LIBS) for quantitative analysis of materials, illustrated by CF-LIBS applied to a brass sample of known composition, is presented in this paper The LIBS plasma is produced by a 355 nm pulsed Nd:YAG laser with a pulse duration of 6 ns focussed onto a brass sample in air at atmospheric pressure The time-resolved atomic and ionic emission lines of Cu and Zn from the LIBS spectra recorded by an Echelle spectrograph coupled with a gated intensified charge coupled detector are used for the plasma characterization and the quantitative analysis of the sample The time delay where the plasma is optically thin and is also in local thermodynamic equilibrium (LTE), necessary for the elemental analysis of samples from the LIBS spectra, is deduced An algorithm relating the experimentally measured spectral intensity values with the basic physics of the plasma is developed Using the algorithm, the Zn and Cu concentrations in the brass sample are determined The analytical results obtained from the CF-LIBS technique agree well with the certified values of the elements in the sample, with an accuracy error <1%

53 citations


Journal ArticleDOI
TL;DR: The limits of Detection of several serum proteins have been estimated with this instrument and are found to be much lower compared to other commonly used proteomics techniques like SELDI, MALDI, 2-D-SDS-PAGE, and so forth.
Abstract: This paper describes the sensitivity study and performance evaluation of high-performance liquid chromatography-laser-induced fluorescence detection (HPLC-LIF) system assembled in our laboratory for proteomics applications. The limits of Detection (LOD) of several serum proteins have been estimated with this instrument and are found to be much lower compared to other commonly used proteomics techniques like SELDI, MALDI, 2-D-SDS-PAGE, and so forth. Techniques for improving the LOD still further with similar setup are briefly discussed. Using the system, protein profiles of serum in normal, malignant, and premalignant conditions were recorded for different malignancy situations.

13 citations