scispace - formally typeset
Proceedings ArticleDOI

Compact 200-Hz pulse repetition GW Marx generator system

Reads0
Chats0
TLDR
In this paper, the authors proposed a high-PRF pulsed power system with an 8 kJ/sec TDK-Lambda high-voltage power supply and an APELC trigger and control unit.
Abstract
The compact, wave-erection, GW-class Marx generator has been previously reported for use in 5 ns to sub-ns risetime pulsed power applications. This generator topology has recently been adapted for high Pulse Repetition Frequency (PRF) applications and is the basis for a new high-PRF pulsed power system. The 33-J generator is capable of delivering a 300-kV pulse into a matched 50-Ohm load, or 600 kV into an open circuit. The high-PRF system includes an 8 kJ/sec TDK-Lambda high-voltage power supply and an APELC trigger and control unit. The APELC trigger unit contains a 150-mJ thyratron-based pulser and facilitates the synchronous pulse charging of the Marx generator. Additionally, the trigger unit provides analog output signals of the thyratron and Marx charging signals and features LED diagnostics and fault indicators on the front panel. Applications of the high-PRF system include sourcing of High Power Antennas. Design considerations, system architecture, and experimental results of the high-PRF pulsed power system are presented in this paper.

read more

Citations
More filters
Proceedings ArticleDOI

Compact Marx generators modified for fast risetime

TL;DR: In this paper, a pulse conditioning system (PCS) that can be retrofitted into the existing MV Marx generator housing to improve output pulse rise time at a minimal cost of stored energy is presented.
Proceedings ArticleDOI

A Marx generator driven impulse radiating antenna

TL;DR: APELC has developed an Impulse Radiating Antenna (IRA) that consists of a TEM-horn-fed parabolic reflector that is directly driven by a 22-J, 400-kV Marx generator.
DissertationDOI

Compact Pulse Modulator for Plasma Channel Drilling

TL;DR: In this article, the authors studied the lower limits of plasma channel drilling (PCD) and designed suitable compact modulators and experimentally found optimum energy levels, and defined specifications for the pulse generator, a literature review was conducted, and the main research has been done with large scale Marx generators with drill bit sizes of more than 10 cm.
Proceedings ArticleDOI

Modular, high-power, wideband transmitters for electromagnetic environmental effects (E3) testing

TL;DR: APELC has developed a suite of high-power, wideband, dipole antennas targeted for use by the test and evaluation and the directed energy communities as mentioned in this paper, which can be sourced by the MG15-3C-940PF Marx generator.
Proceedings ArticleDOI

Particle in cell simulation of peaking switch for breakdown evaluation

TL;DR: In this paper, the particle in cell (PIC) simulation for the peaking switch was performed using MAGIC 3D software, and the particle charge density, current density, E counter plot, emitted electron current, and particle energy along the axis of gap between electrodes were analyzed.
References
More filters
Proceedings ArticleDOI

Some future directions for repetitive pulsed power

TL;DR: This paper attempts to identify a few areas where large growth seems likely over the next decade and to highlight the drivers for substantial breakthroughs.
Proceedings ArticleDOI

A Modular Compact Marx Generator Design for the Gatling Marx Generator System

TL;DR: The Gatling Marx generator system has been previously discussed for its ability to deliver energy from multiple generators into a single cable with demonstrations of the GatlingMarx as mentioned in this paper, which brings the need for a modular and compact design, high repetition rate capability, and enhanced controller capabilities, including control over the charge voltage, pressure regulator and trigger.
Related Papers (5)