scispace - formally typeset
Journal ArticleDOI

Experimental investigation into the structural behaviour of lapped connections between cold-formed steel Z sections

H.C. Ho, +1 more
- 01 Jul 2004 - 
- Vol. 42, Iss: 7, pp 1013-1033
Reads0
Chats0
TLDR
In this paper, the structural performance of lapped cold-formed steel Z sections was investigated and a set of rational design rules for multi-span purlin systems with overlaps in modern roof construction was developed.
Abstract
This paper presents an experimental investigation on the structural behaviour of lapped cold-formed steel Z sections. A total of 26 one point load tests on lapped connections between Z sections with various lap lengths and test spans were carried out, and both the strength and the deformation characteristics of these connections were examined in detail. Among all tests, section failure at the end of lap under combined bending and shear was always found to be critical in the connected Z sections. Moreover, the moment resistances of lapped connections with lap lengths equal to 1.2 times section depth were found to develop only 80% of the moment capacities of connected sections. For lapped connections with lap lengths equal to six times section depth, their moment resistances were found to be significantly increased to about 140% of the moment capacities of connected sections. Similar results in the flexural rigidities of the lapped connections were also found. Consequently, it is shown that the degree of structural continuity in lapped connections against bending depend on not only the load levels, the lap length to section depth ratios, but also the lap length to test span ratios. Hence, the widely adopted assumption of full strength and stiffness connections in lapped sections is not always correct. The research work aims to provide understanding to the structural performance of lapped connections between cold-formed steel Z sections, and hence, to develop a set of rational design rules for multi-span purlin systems with overlaps in modern roof construction. The analysis and design method will be fully presented in a complementary paper.

read more

Citations
More filters
Journal ArticleDOI

Review on Cold-Formed Steel Connections

TL;DR: Current researches on cold-formed steel connections, particularly for screw connections, storage rack connections, welded connections, and bolted connections, are reviewed.
Journal ArticleDOI

Experimental work on cold-formed steel elements for earthquake resilient moment frame buildings

TL;DR: In this paper, the use of thin-walled cold-formed steel (CFS) sections as energy dissipative elements for earthquake resistant moment frame multi-storey buildings was investigated.
Journal ArticleDOI

Development of cold-formed steel elements for earthquake resistant moment frame buildings

TL;DR: In this article, the development of thin-walled cold-formed steel (CFS) sections as energy dissipative elements for seismic moment-resisting multi-storey frame buildings is presented through FE analysis and experimental work.
Journal ArticleDOI

Analysis and design of lapped connections between cold-formed steel Z sections

TL;DR: In this paper, an analysis and design method for lapped connections between cold-formed steel Z sections is presented, based on the experimental observations on the lapped connection tests where combined bending and shear is always critical in the cross-sections at the end of laps.
Journal ArticleDOI

Ductile moment-resisting frames using cold-formed steel sections: An analytical investigation

TL;DR: In this paper, the authors investigated the potential use of cold-formed steel sections (CFS sections) in moment-resisting frames (MRFs) for seismic applications, and proposed beam-column connections through plates which potentially limit the out-of-plane action of the forces transferred through the connections.
References
More filters
Journal ArticleDOI

Analysis and design of lapped connections between cold-formed steel Z sections

TL;DR: In this paper, an analysis and design method for lapped connections between cold-formed steel Z sections is presented, based on the experimental observations on the lapped connection tests where combined bending and shear is always critical in the cross-sections at the end of laps.
Journal ArticleDOI

Behavior of Cold-Formed Steel Purlins Under Gravity Loading

TL;DR: In this paper, full-scale tests of cold-formed steel C- and Z-section purlins supporting conventional (through-fastened) metal-building roof panels were tested under gravity loading.
Journal ArticleDOI

Structural performance of modern roofs with thick over-purlin insulation—Experimental investigation

TL;DR: Chung et al. as mentioned in this paper presented an experimental investigation on the structural performance of five modern roof systems with thick over-purlin insulation, and compared the performance of these five modern roofs under both gravity and uplift loading conditions.
Journal ArticleDOI

Governing Stresses in Z-Purlin Lap Joints

TL;DR: In this article, 28 stiffened Z-section beams were transversely loaded to failure and stresses in the lap joints were investigated, and the results indicated that the lapping process significantly enhanced the load capacity and stiffness of the beams for lap-to-span ratios up to 0.5.
Journal ArticleDOI

Load Capacity of Nested, Laterally Braced, Cold-Formed Steel Z-Section Beams

TL;DR: In this article, cold-formed steel Z-purlins were tested in combined bending and shear to evaluate the behavior of lap joints, and the results indicated that the lapping process significantly enhances the load capacity for beams with lap-to-span ratios up to 0.5.