Recommended Practice for the Calibration of Mass Spectrometers
James A. Basford,Mark D. Boeckmann,Robert E. Ellefson,Albert R. Filippelli,David H. Holkeboer,Laslo Lieszkovsky,Catherine M. Stupak +6 more
Reads0
Chats0
TLDR
In this article, the authors present an introduction to partial pressure analyzers and how they work, equipment needed for calibration, instrument setup prior to calibration and the measurement of sensitivity and linearity by various methods.Abstract:
This Recommended Practice addresses issues involved in the use of partial pressure analyzers (PPAs) for quantitative analysis and describes recommended apparatus and procedures for determining resolution and sensitivity of a PPA so that the instrument can be used quantitatively for partial pressure, partial flow and gas composition analysis. This updates previous material in the AVS Standard 2.3-1972 (tentative) by including reference to current pressure transfer standards and computer controlled PPAs. This document presents an introduction to PPAs and how they work, definitions pertinent to the use of PPAs, equipment needed for calibration, instrument setup prior to calibration and the measurement of sensitivity and linearity by various methods. Four methods of calibration of a PPA are described as follows: (1) the direct comparison of the PPA output with a transfer standard pressure gauge, (2) the indirect comparison of PPA readings with readings of a transfer standard pressure gauge separated by a flow restriction (pressure divider method), (3) comparison of the PPA output response to known gas flow rates. The first three methods may be carried out on a test stand of suitable design or in situ. The fourth method requires that the pumping speed during calibration be the same as the pumping speed during use, and normally implies that the PPA is calibrated in situ. Discussion on gas interactions, sources of nonlinearity, stability of sensitivity and quality assurance methods is given.read more
Citations
More filters
Journal ArticleDOI
Mixed-matrix membranes containing MOF-5 for gas separations
TL;DR: In this article, metal-organic framework 5 (MOF-5) nanocrystals with a high surface area (3000m 2 /g) and high thermal stability (up to 400°C) were synthesized and added to Matrimid ® to form mixed-matrix membranes for gas separations.
Journal ArticleDOI
A novel time lag method for the analysis of mixed gas diffusion in polymeric membranes by on-line mass spectrometry: method development and validation
Sofia C. Fraga,Marcello Monteleone,Marek Lanč,Elisa Esposito,Alessio Fuoco,Lidietta Giorno,Kryštof Pilnáček,Karel Friess,Mariolino Carta,Neil B. McKeown,Pavel Izák,Zuzana Petrusová,João G. Crespo,Carla Brazinha,Johannes C. Jansen +14 more
TL;DR: In this paper, a novel method to determine the individual diffusion coefficients of gases in a mixture during their permeation through polymeric membranes is described, using Rubbery Pebax ® and glassy Hyflon ® AD60X membrane samples as standards, and validated using the Troger's base containing Polymer of Intrinsic Microporosity, PIM-EA-TB.
Journal ArticleDOI
Complementary and Emerging Techniques for Astrophysical Ices Processed in the Laboratory
Marco A. Allodi,Raúl A. Baragiola,G. A. Baratta,M. A. Barucci,Geoffrey A. Blake,Philippe Boduch,John Robert Brucato,C. S. Contreras,Steven H. Cuylle,Daniele Fulvio,Murthy S. Gudipati,Murthy S. Gudipati,Sergio Ioppolo,Z. Kaňuchová,Antti Lignell,Harold Linnartz,Maria Elisabetta Palumbo,Ujjwal Raut,Hermann Rothard,Farid Salama,Elena V. Savchenko,Ella Sciamma-O'Brien,Giovanni Strazzulla +22 more
TL;DR: In this article, the authors present an overview of the techniques being used in astrochemical laboratories worldwide, but it is incomplete in the sense that it summarizes the outcome of a 3-day workshop of the authors in November 2012, with several laboratories represented, but not all.
Journal ArticleDOI
Metal-organic polyhedra 18 mixed-matrix membranes for gas separation
TL;DR: In this article, metal-organic polyhedra 18 (MOP-18) linker was functionalized with long alkyl chains to help the crystals dissolve in common organic solvents.
Journal ArticleDOI
Decomposition of Phenolic Impregnated Carbon Ablator (PICA) as a Function of Temperature and Heating Rate.
TL;DR: The heating rate strongly affects the pathways taken during the pyrolysis of the phenolic resin in PICA, and the new data may be used to test nonequilibrium models that are designed to simulate the response of TPS materials during atmospheric entry of spacecraft.